AGILTRON EDFA-1C0(2)111xxx-xx SM Booster EDFA Mini Module User Manual
- May 15, 2024
- AGILTRON
Table of Contents
A Photonwares Company
C-Band 17/20dBm SM Booster EDFA
Mini Module with 20/30dB Gain
User Manual
P/N: EDFA-1C0(2)111xxx-xx
(Jan, 2022)
EDFA-1C0(2)111xxx-xx SM Booster EDFA Mini Module
![]()
Ambient Parameters
| Parameter | Min. | Typical | Max. | Unit | Note |
|---|---|---|---|---|---|
| Working Temperature | -5 | 65 | ℃ | ||
| Storage Temperature | -40 | 85 | ℃ | ||
| Working Relative Humidity | 5 | 85 | % | 40°C non- condensation | |
| Storage Relative Humidity | 5 | 95 | % |
Optical Parameters
| Parameter | Min | Typical | Max | Unit | Note |
|---|---|---|---|---|---|
| Return Loss | 45 | – | – | dB | |
| Input & Output Fiber type | SMF-28e, 900um white loose tube | – | |||
| Output Fiber Length | 99 | 100 | 101 | cm | 100 ± 1cm, without connector |
| Input Fiber Length | 99 | 100 | 101 | cm | 100 ± 1cm, without connector |
| Input & Output Fiber Connector Type | FC/APC | – | |||
| Module Dimension | (WLH)907015 | mm | |||
| Working Mode | AGC | ||||
| No Optical Power Report | -60 | dBm | |||
| Output power stability | – | – | ±0.1 | dB | |
| Accuracy of power reporting | – | – | ±0.5 | dB | |
| Gain control accuracy | – | – | ±0.5 | dB | |
| Output Power control accuracy | – | – | ±0.5 | dB | |
| Input & Output Isolation | – | 35 | – | dB | |
| In & Out Pump Leakage | – | – | -30 | dBm | |
| PDG | – | – | 0.5 | dB | |
| PMD | – | – | 0.5 | ps | |
| CD | – | – | ±5 | ps/nm | |
| Multipath interference | – | – | -40 | dB | |
| Operating Wavelength | 1528 | – | 1565 | nm | |
| Input Power Range | -30 | – | 10 | dBm | |
| Gain | 20 | 20/ 30 | 33 | dB | Flatness<2.0 Gain adjustable range is ±1.5dB. |
Accuracy of normal temperature gain setting is 0.1dB.
Max Output Power| 17/20| dBm|
Input @ Typical| -10| dBm|
NF| –| 5.5| 6| dB| @Gain=20dB
GF| –| 1| 1.5| dB| @In=-3dBm,G=20dB
Input Power Alarm Threshold| -33| -31| -10| dBm| Settable range -33 ~ -10
dBm,Upward hysteresis 1dB,<-33dBm reporting no optical power
Output Power Alarm Threshold| -8| -6| 20.5| dBm| Settable range -8 ~ +20.5,
Upward hysteresis 1dB, <-8 reporting no optical power
Pump off threshold| -33| -33| -10| dBm| Settable range -33~-5, Upward
hysteresis 1dB
---|---|---|---|---|---
APC Output power setting range| -5| –| 20| dBm| Setting accuracy is 0.1dB
Default temperature alarm threshold| -5| 70| 70| ℃| Settable range -5~+70℃
Upward hysteresis 1℃
Ports| –| 2| –| –| Input & output
Electrical Indicators
3.1 Power Supply:
| Parameter | Min | Typical | Max | Unit | Note |
|---|---|---|---|---|---|
| Voltage | 4.75 | 5.0 | 5.25 | V | |
| Current | – | – | 3.0 | A | |
| Power Consumption | – | – | 15 | W |
3.2 Pin definition
3.2.1 Communication Port
Type:34Pin 2.00mm intervals male socket CJT A2005WV-N-2x17P
3.2.2 Pin definition:
| Pin No. | Name | Attribute | Level Type |
|---|---|---|---|
| 1 | NC | F | |
| 2 | NC | F | |
| 3 | +5V | P | |
| 4 | +5V | P | |
| 5 | +5V | P | |
| 6 | +5V | P | |
| 7 | GND | P | |
| 8 | GND | P | |
| 9 | NC | F | |
| 10 | NC | F | |
| 11 | GND | P | |
| 12 | GND | P | |
| 13 | NC | F | |
| 14 | NC | F | |
| 15 | NC | F | |
| 16 | NC | F | |
| 17 | NC | F | |
| 18 | NC | F | |
| 19 | NC | F | |
| 20 | NC | F | |
| 21 | NC | F | |
| 22 | NC | F | |
| 23 | GND | P | |
| 24 | GND | P | |
| 25 | Serial Port Input | I | LVTTL |
| 26 | Serial Port Output | O | LVTTL |
| 27 | GND | P | |
| 28 | GND | P | |
| 29 | +5V | P | |
| 30 | +5V | P | |
| 31 | +5V | P | |
| 32 | +5V | P | |
| 33 | NC | F | |
| 34 | NC | F |
Serial Port Communication Protocol
| Parameter | Value | Unit |
|---|---|---|
| Baud rate | 9600 | Bit/s |
| Data bit | 8 | Bit |
| Stop bit | 1 | Bit |
| Parity bit | None |
Module Dimensions


References