Bench-top C-Band SM Booster EDFA
User Manual
P/N: EDFA-xCxx12xxx
(Oct, 2022)
EDFA-xCxx12xxx Bench Top C Band SM Booster
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED LASER LIGHT
Warning
When Emission Button is turned on and there is sufficient laser power to the
input port of this device its output will be on at the power level previously
set at factory, which is 30dBm. This power level can be changed though
provided GUI.
Warning
- Only single mode fiber (SMF, 9/125μm) cable is compatible to this EDFA. Using of other fiber cables, including multimode fiber cables and single-mode fiber cables with different core size, may cause poor performance or even damage to the EDFA.
- Only FC/APC connectors are allowed.
- Clean and inspect connectors and fiber ends prior to installation.
- Use only industry approved methods, materials, and solutions for cleaning.
- Always turn off the EDFA prior to plugging/unplugging fiber cable. Failure to do so may cause permanent damage to the EDFA.
Summary
This booster EDFA works in C-band. Its front panel is shown in Figure 1.
-
The module needs 100-240V AC power. Its on-off power switch locates on rear panel.
Note: the RS-232 port on the rear panel is not functional for this model. -
The FC/APC connectors on its front panel are for laser input and output. SMF-28 optical fiber cables are required for this model.
-
The micro-USB port is for remote control.
-
The Emission Button is for ON/OFF of whole unit.
Note:
a. When it is OFF USB functions are disabled.
b. The EDFA is designed to work between -10 ~ 60°C temperature range. Humidity
should not exceed 90%. Installation is recommended in a temperature & humidity
controlled, dust-free environment.
Connection and Operation
Warning
- This EDFA will have 30dBm output once the ‘Emission’ button lights up and > -5dBm input laser power is sent to the input port, even without GUI connection.
- An initial 30dBm output was set in factory and can be changed and saved by using GUI.
-
Plug the AC power cord into the receptacle on the rear panel of the module, and connect to 100-240V AC power source.
-
Clean the FC/APC connectors of SMF-28 fiber cables properly, and then connect them to the corresponding input/output ports.
Note: ensure that the wavelength and power of the input light are within the EDFA specifications, i.e. -5 ~ 10dBm @ 1550nm. -
Turn power on using the rocker switch on the rear panel of the device.
-
Push the Emission button down to turn on the whole device. The Emission Button will be lighted up in blue. Now the device will have 30dBm output power.
-
Connect the micro-USB port on the front panel to a computer by using the USB cable coming with the device.
-
Remote software control (GUI) provided can be used for getting EDFA status, changing output power, saving setting, etc. Please see Part 4 for detailed instruction.
-
Pushing the Emission button to turn off the EDFA.
Software Instruction
Note:
USB to COM driver for FTDI devices needs to be installed on the computer for
remote control. The driver can be downloaded from
https://ftdichip.com/drivers/vcp-drivers/.
-
Download GUI software ‘EDFA GUI V2.0’ from the link below, under Other Download. https://photonwares.com/product/erbium-doped-fiber-amplifier-module/
-
Unzip the file and run setup.exe to install the GUI on host computer.
| Figure 4: Remote control software: connected successfully.
---|--- -
Turn on Emission on the front panel of the EDFA to power up the whole unit and enable USB functions.
-
Run EDFA GUI V2.0.
-
Choose device model
• EDFA-H: standard version EDFAs with 30dBm or higher output power.
• EDFA-L: standard version EDFAs with less than 30dBm output power.
• EDFA-C: high-end or special version EDFAs. -
Port Selection: Select the serial port, to which the EDFA is connected, from the ‘Port List’, and click ‘Connect’. If the desired port doesn’t show up click ‘Refresh’ button and try again.
-
Once EDFA has been connected successfully the status of the EDFA will be displayed in Monitor Status window. The status keeps updating at an interval of 1 second.
-
Check Setting
Click to get the settings from the EDFA. -
Pump ON/OFF
Click to turn on/off the EDFA pump laser, thus to turn on/off its output. -
Control Mode Selection
Click ‘Control Mode’ button to get the current mode setting of EDFA.
• Power Control: constant power control mode
• Current mode: constant current control mode
Select the desired mode and input setting value into the corresponding ‘Set Power(dBm)’ or ‘Set Current(mA)’ box, then click ‘Set’ button. -
Save Settings
Click ‘Save Settings to Amplifier’ button to save all current settings to EDFA, including output power level and control mode.
When turn on the EDFA next time it will run under saved settings, even without GUI connection. -
Emission ON/OFF
Click ‘Pump ON’ or ‘Pump OFF’ button to turn on/off the output of EDFA.
A Photonwares Company
15 Presidential Way
Woburn, MA 01801
Tel:781-935-1200
Fax:781-935-2040
www.agiltron.com
Documents / Resources
|
AGILTRON EDFA-xCxx12xxx Bench Top C Band SM
Booster
[pdf] User Manual
EDFA-xCxx12xxx Bench Top C Band SM Booster, EDFA-xCxx12xxx, Bench Top C Band
SM Booster, Band SM Booster, Booster
---|---
References
- Home - Industry-leading Optical Switches/Attenuators - Agiltron Inc.
- EDFA Fiber Optical Amplifier - Agiltron Inc.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>