SFA 9071 Sanimulti Macerator SA222 From Reece User Manual

June 13, 2024
SFA

SFA 9071 Sanimulti Macerator SA222 From Reece

SFA-9071-Sanimulti-Macerator-SA222-From-Reece-PRO

Product Information

  • Product Name: Sanimulti
  • Product Code: 9071
  • Release Date: 11.2021
  • Description: The Sanimulti is a compact versatile macerator pump designed for light-medium commercial use. It is designed to receive and pump away waste water from a WC, bath, shower, and basin.

SAFETY

DISCONNECT ELECTRICAL POWER BEFORE WORKING ON THE PUMP !
Plumbers/Contractors, please ensure a copy of the installation instructions is left with the end user for future reference.

RECOMMENDEND USE
The Sanimulti is a compact versitile macerator pump designed for light – medium commercial use. The unit is designed to re-ceive and pump away waste water from a WC, bath, shower & basin.

NOTICE

  • DO NOT dispose of solvents, paints, turps, caustic acid, or other corrosive acids or cleaners.
  • DO NOT dispose of hot water in excess of 60°C.
  • DO NOT use cleaning products that produce excessive foam, this may cause motor damage.
  • DO NOT install in a hairdressing salon without the use of a hair trap first.
  • DO NOT dispose of paper hand towels, sanitary napkins or wet wipes.
  • DO NOT dispose of forign objects or use excessive amounts of toilet paper.

DESCRIPTION

TECHNICAL DATA

Product Code and Description| SA222 – Sanimulti light commercial macerator pump
---|---
Electrical Power Supply| 220 – 240 V/ 50 Hz
Nominal Current| 2.5 A
Motor Power Rating| 560 W
Vertical Pumping Height| Up to 8 meters
Horizontal Pumping Distance| Up to 70 meters
Maximum Temperature| 40 °C
Inlets| 3 + 2 optional
---|---
Recommended Waster Water pipe| DN25
Inlet Diameter| DN100 – 40mm
Venting| Optional external vent connection
Alarm| Included
Casing| White
Dimensions| 505 x 361 x 205 mm (W x H x D)

FLOW CHARACTERISTICS

PUMPING DISTANCE PERFORMANCE

DIMENSIONS

INSTALLATION

  • The macerator pump should be installed to allow full access in the event that servicing or removal is required. Where the unit is concealed in the wall cavity a 500mm access panel must be provided
  • The unit must be located on the same floor as the fittings it is to service.
  • All incoming pipework must have a constant gradient of 1:40.
  • The unit has 2 lower lateral inlet ports. If an inlet is not in use, cap off the inlet with side plug.
  • The top of the unit has a dedicated vent point with interated carbon filter to neutralize odors, this point can also be used as optional external vent to atmosphere connection point.
  • Where possible, venting should always be consistent to current plumbing venting requirements as per AS 3500.
  • Before commissioning the unit, make sure all connections are secure and watertight.
  • The electrical installation should be carried out by a registered eletrician in accordance with AS/NZS 3000.
  • AAV valves are not an alternative to venting to atmosphere as the unit needs to have two-way venting for correct activation function.

CONNECTING P TRAP, WALL FACE OR WALL-MOUNTED PAN INSTALLATION
In delivered condition the pump comes assembled with the toilet connection already prepared side entry (Fig 1), use supplied pan connector for standard P trap toilet suite or to connect to 100 mm DWV pipe for remote installation (wall hung pan etc.). If direct connection to toilet pan is required configuration can be changed to (Fig 2).SFA-9071-Sanimulti-Macerator-SA222
-From-Reece- \(4\)

IMPORTANT REMOVING ACCESSORIES
NOTE Check to see that all accessory parts are taken out of the pump unit!SFA-9071-Sanimulti-Macerator-SA222-From-Reece-
\(5\)SFA-9071-Sanimulti-Macerator-SA222-From-
Reece- \(6\)

RELOCATING PAN INLET CONNECTOR

SFA-9071-Sanimulti-Macerator-SA222-From-Reece- \(7\)SFA-9071-Sanimulti-Macerator-SA222-From-Reece-
\(8\) SFA-9071-Sanimulti-Macerator-SA222-From-
Reece- \(9\) SFA-9071-Sanimulti-Macerator-
SA222-From-Reece- \(10\)

PUMP LINE CONNECTION
The pressure line is fed out at the top from the device. According to the installation conditions, the pressure outlet can be fed out straight or by using a 90° elbow. Using the included hose clips, the pressure line is connected and fixed. The pressure line must have a minimum internal diameter of 20 mm. The correct installation position of the discharge elbow with an integrated non-return valve must be observed. A PVC pressure ball must be installed on the pump line for isolation to facilitate servicing.

  1. Connection option using a multi-hose connection:SFA-9071-Sanimulti-Macerator-SA222-From-Reece- \(11\)
  2. Connection option with double threaded nipple 1 1/4’’:SFA-9071-Sanimulti-Macerator-SA222-From-Reece- \(12\)

VENTING
This pump comes with an integrated active carbon filter with an anti-flood valve, the active carbon in the filter is designed to neutralize odor emitted during the course of normal hydraulic function. Where possible, venting should always be consistent to current plumbing venting requirements as per AS 3500. Position of venting (with activated carbon) upon delivery:

Changing the venting position:SFA-9071-Sanimulti-Macerator-SA222-From-
Reece- \(14\) SFA-9071-Sanimulti-Macerator-
SA222-From-Reece- \(15\)

ADDITIONAL CONNECTIONS

  1. Upper connectionsSFA-9071-Sanimulti-Macerator-SA222-From-Reece- \(16\)SFA-9071-Sanimulti-Macerator-SA222-From-Reece- \(21\)SFA-9071-Sanimulti-Macerator-SA222-From-Reece- \(17\)
  2. Lateral inlets
    The lateral inlets for the connection of a shower:

FIXING
The pump can be firmly secured to the floor using the supplied fixation brakets and tap screws.SFA-9071-Sanimulti-Macerator-SA222-From-Reece-
\(18\)

CONNECTING A SHOWER
When connecting a shower to the Sanimulti the shower must be elevated to a height of no less than 170 mm from the shower grate to the base of the pump on finished floor level whilst maintaining 1:40 or 3% gradient on the shower waste fixture line.SFA-9071-Sanimulti-Macerator-SA222-From-Reece-
\(19\)

HIGH-LEVEL CONTROL SANIALARM INTERLOCK CONNECTION (OPTIONAL)
Fig 1 shows Sanialarm Interlock has a socket connection marked «Quick plug float switch». Plug one end of supplied accessory lead to this connection, as indicated. Plug the other end of supplied lead to connection indicated on the pump (Fig 2). Finish connecting Sanialarm Interlock as per instructions supplied with alarm.SFA-9071-Sanimulti-Macerator-SA222-From-Reece-
\(20\)

TROUBLESHOOTING GUIDE

For repair and maintenance works on the pump, always disconnect the power plug from the power socket.

Malfunction Cause Troubleshooting
Motor does not run Supply voltage missing Check the socket Insert the power

plug
Cutting knife blocked| Remove/clear object, test run
Motor overloaded| Thermal protection switches off the motor, in case of recurrence, remedy by qualified staff/customer service
Control defective| Remedy by qualified staff/ customer service
Motor defective| Replacement (customer service)
Motor runs, but waste will not discharge| Discharge pressure line blocked| Clear blockages, carry out test run
Pump ventilation clogged| Pull off pump ventilation hose, clean hose and nozzle
Check valve incorrectly installed| Rotate, check function
Tank ventilation clogged| Replace activated carbon filter
Motor runs in short intervals| Ventilation clogged| Pull off pump ventilation hose, clean hose and nozzle
Check valve leaking| Clean or replace check valve
Cistern valve leaking| Rectify/replace
Motor makes loud foreign or rattling noise| Foreign object has got into the device| Remove/clear object, test run
Alarm sounds| Too high filling level| Check for power disconnection, and blockages and contact Saniflo Technical for service/assistance

WARRANTY

2 YEAR WARRANTY
This device is guaranteed for 2 years from the date of purchase and is subject to ACL (2) 2010 and NZ CG Act 1993 if used for personal, domestic and household use. Installation in strict compliance with manufacturers’ installation.

Read more at:

WARRANTY CONDITIONS
This warranty will apply only under all of the following conditions:

  • The item has been installed by a licensed plumber
  • Failure is due to a fault in the manufacture of the product
  • Proof of purchase (including the date of purchase) is provided
  • The installation of the product is in accordance with the instructions provided.

SANIFLO Australasia Pty Ltd, Unit 9-10, 25 Gibbes Street Chatswood NSW 2067 Tel. 1300 554 779 SANIFLO New Zealand Pty Ltd, Tel. 0 800 107 064

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SFA User Manuals

Related Manuals