AMERISTAR A4AH6E43A1C30B 3.5 Ton Convertible Air Handler Instruction Manual
- June 4, 2024
- AMERISTAR
Table of Contents
Submittal
3.5 Ton
Convertible Air Handler
A4AH6E43A1C30B March 2022
AA44AAHH66EE4433AA11CC–SSUUBB–11BB–EENN
Outline Drawing
MINIMUM UNIT CLEARANCE TABLE
| SERVICE CLEARANCE (RECOMMENDED)
SIDES| 2″
FRONT| 21″
BACK| 0″
INLET DUCT| I”
OUTLET DUCT| N/A
NOTE: THIS UNIT IS APPROVED FOR INSTALLATION CLEARANCES TO COMBUSTIBLE
MATERIAL AS STATED ON THE UNIT RATING NAMEPLATE
NOT E: ALL DIMENSIONS ARE REFERENCE DIMENSIONS
PRODUCT DIMENSIONS
Air Handler Model| A| B| C| D| E| F| H| Flow Control| Gas Line Braze
A4AH6E43A1C| 51.27| 23.50| 21.50| 21.75| 7.01| 9.66| 24.59| TXV| 7/8
All dimensions are in inches
Product Specifications
MODEL | A4AH6E43A1C30B |
---|---|
RATED VOLTS/PH/HZ | 208-230/1/60 |
RATINGS (a) | See O.D. Specifications |
INDOOR COIL — Type | Plate Fin |
Rows — F.P.I. | 4 – 14 |
Face Area (sq. ft.) | 4.59 |
Tube Size (in.) | 3/8 |
Refrigerant Control | TXV |
Drain Conn. Size (in.)(b) | 3/4 NPT |
DUCT CONNECTIONS | See Outline Drawing |
INDOOR FAN — Type | Centrifugal |
Diameter-Width (In.) | 11 X 8 |
No. Used | 1 |
Drive – No. Speeds | Direct – 5 (c) |
CFM vs. in. w.g. | See Fan Performance Table |
No. Motors — H.P. | 1 – 1/2 |
Motor Speed R.P.M. | 1050 |
Volts/Ph/Hz | 208-230/1/60 |
F.L. Amps | 4.1 |
FILTER | |
Filter Furnished? (d) | No |
REFRIGERANT | R-410A |
Ref. Line Connections | Brazed |
Coupling or Conn. Size — in. Gas | 7/8 |
Coupling or Conn. Size — in. Liq. | 3/8 |
--- | --- |
DIMENSIONS | H x W x D |
Crated (In.) | 52–3/4 x 27–1/2 x 25–1/2 |
Uncrated | 51-3/8 x 23-1/2 x 21-1/8 |
WEIGHT | |
Shipping (Lbs.) / Net (Lbs.) | 155/144 |
(a) These Air Handlers are A.H.R.I certified with various Split System Air
Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System
Outdoor Unit Product Data Guides for performance data.
(b) 3/4” Male Plastic Pipe (Ref: ASTM 1785–76)
(c) ECM Motor
(d) Remote filter required.
Minimum Airflow CFM
A4AH6E43A1C30B
Heater| Minimum Heat Speed Tap
| With Heat Pump| Without Heat Pump
BAYHTR1504BRK, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505LUG| Low| Low
BAYHTR1508BRK, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510LUG| Med-High|
Med-Low
BAYHTR1523BRK| Med-High| Med
BAYHTR1517BRK, BAYHTR3517LUG, BAYHTR3510LUG| High| Med
Heater Pressure Drop Table
Airflow CFM
| Number of Racks| | Heater Racks
---|---|---|---
1| 2| 3| 4| Heater Model| No. of Racks
Air Pressure Drop — Inches W.G.| BAYHTR1504| 1
1800| 0.02| 0.04| 0.06| 0.14| BAYHTR1505| 1
1700| 0.02| 0.04| 0.06| 0.14| BAYHTR1508| 2
1600| 0.02| 0.04| 0.06| 0.13| BAYHTR1510| 2
1500| 0.02| 0.04| 0.06| 0.12| BAYHTR1517| 3
1400| 0.02| 0.04| 0.06| 0.12| BAYHTR3510| 3
1300| 0.02| 0.04| 0.05| 0.11| BAYHTR3517| 3
1200| 0.01| 0.04| 0.05| 0.10| BAYHTR3515| 3
1100| 0.01| 0.03| 0.05| 0.09| BAYHTR1523| 4
1000| 0.01| 0.03| 0.04| 0.09| BAYHTR1525| 4
900| 0.01| 0.03| 0.04| 0.08| |
800| 0.01| 0.03| | | |
700| 0.01| 0.02| | | |
600| 0.01| 0.02| | | |
Performance and Electrical Data
- See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters.
- Heater model numbers may have additional suffix digits.
Table 1. Air Flow Performance
A4AH6E43A1C30B
EXTERNAL STATIC(in w.g)| AIRFLOW
Speed Taps — 208 – 230 VOLTS
| High| Med-High| Med †| Med-Low| Low
0.1| 1491.6| 1418.1| 1302.5| 1267.8| 1140.4
0.2| 1459.7| 1384.7| 1266.3| 1230.1| 1096.4
0.3| 1425.8| 1349.2| 1227.8| 1189.7| 1050.3
0.4| 1389.8| 1311.3| 1187.0| 1146.8| 1002.1
0.5| 1351.6| 1271.3| 1144.0| 1101.4| 951.7
0.6| 1311.4| 1229.0| 1098.7| 1053.3| 899.3
0.7| 1269.1| 1184.4| 1051.1| 1002.7| 844.7
Notes:
1. Values are with wet coil, no filter, and no heaters
2. CFM Correction for dry coil = Add 3%
3.† = Factory Setting
4. In downflow applications, airflow must not exceed 1600 cfm due to
condensate blowoff.
5.Low = Tap 1, Med-Low = Tap 2, Med = Tap 3, Med-High= Tap 4, High = Tap 5
Table 2. Electrical Data
A4AH6E43A1C30B
Heater Model No.| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload
Protection| Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity|
Maximum Overload Protection
kW| BTUH| kW| BTUH
No Heater| | | | 4.1 | 8| 15| | | 4.1 | 8| 15
BAYHTR1504BRK BAYHTR1504LUG| 1/1| 3.8| 13100| 16.0| 28| 30| 2.9| 9800| 13.8|
25| 25
BAYHTR1505BRK BAYHTR1505LUG| 1/1| 4.8| 16400| 20.0| 33| 35| 3.6| 12300| 17.3|
29| 30
BAYHTR1508BRK BAYHTR1508LUG| 1/1| 7.7| 26200| 32.0| 48| 50| 5.8| 19700| 27.7|
42| 45
BAYHTR1510BRK BAYHTR1510LUG| 1/1| 9.6| 32800| 40.0| 58| 60| 7.2| 24600| 34.6|
51| 60
BAYHTR1517BRK- Circuit 1 (a)| 2/1| 9.6| 32800| 40.0| 58| 60| 7.2| 24600| 34.6|
51| 60
BAYHTR1517BRK- Circuit 2| 4.8| 16400| 20.0| 25| 25| 3.6| 12300| 17.3| 22| 25
BAYHTR1523BRK- Circuit 1| 2/1| 9.6| 32800| 40.0| 58| 60| 7.2| 24600| 34.6| 51|
60
BAYHTR1523BRK- Circuit 2| 9.6| 32800| 40.0| 50| 50| 7.2| 24600| 34.6| 43| 45
BAYHTR3510LUG| 1/3| 9.6| 32800| 23.1| 36| 40| 7.2| 24600| 20.0| 32| 35
BAYHTR3517LUG| 1/3| 14.4| 49100| 34.6| 50| 50| 10.8| 36900| 30.0| 44| 45
BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A| 1/1|
14.4| 49200| 60.0| 83| 90| 10.8| 36900|
51.9| 73| **** 80
- = Motor Amps
(a) MCA and MOP for circuit 1 contain the motor amps.
Features and Benefits
- Galvanized metal cabinet with captured foil face insulation
- 2% or less air leakage
- R-4.2 Insulating Value
- Multi-Position UP/Down Flow, Horizontal Left /Right
- ALL Aluminum Coil
- Electric Heaters with polarized plug connections (sold as accessories)
- R-410A Thermal Expansion Valve
- ECM Motor ((33..55 –– 55 TToonn MMooddeellss ))
- Low Voltage Pigtail Connections
- Draw Through Design
- Horizontal Drain pan
- Single Color
- Fused 24V Power
- 5-year warranty
- Optional extended warranty available
Important: Condensate management kit is required for all 5-ton air handler models installed in downflow applications.A4AH6E43A1C-SUB-1B
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy-efficient indoor
environments for residential applications.
For more information, please visit www.trane.com or
www.americanstandardair.com.
The manufacturer has a policy of continuous data improvement and it reserves
the right to change design and specifications without notice.
We are committed to using environmentally conscious print practices.
A4AH6E43A1C-SUB-1B-EN 09 Mar 2022
Supersedes A4AH6E43A1C-SUB-1A-EN (December 2020) ©2022
References