WARNING! SHUT POWER OF F AT FUSE OR CIRCUI T BRE AKER.
PREPARATION
- Shut off power at the fuse box or circuit breaker box. If necessary remove the old fixture and mounting hardware.
- Carefully unpack your new fixture and lay out all the parts on a clear area. Take care not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (FIG. 1)
3. Secure mounting back plate (B) to junction box (A) using junction boxes screws (C) (Size: 8-32*1/2”L). The side of the mounting back plate marked “GND” must face out.
CONNECTING THE WIRES (FIG. 2)
4. At this point, connect the electrical wires as shown in Fig. 2, making
sure that all wire connectors are secured. If your outlet has a ground wire
(green or bare copper), connect the fixtures ground wire to it. Otherwise,
connect the fixture ground wire directly to the back plate (B) using the green
screw (E) provided. After wires are connected, tuck them carefully inside the
junction box.
5. Place the fixture’s back plate (G) over the mounting back plate and secure
with screws (H).
FINISHING THE INSTALLATION (FIG.1)
6. Slide the glass shade (J) into the front bracket (K) and secure the shield (L) to the front bracket with screws (M).
CAUTION /ATTENTION : When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base or front bracket (K) only.
Replacing LED module (Fig. 3)
The LED module can be replaced by a qualified electrician without cutting of
wire and without damage to any decorative element to which the fixture is
attached. See installation steps for more details (Fig 3.)
a. Remove screws (M) shield (L) and glass shade (J).
b. Remove the wire nuts located inside the fixture backplate to disconnect the
LED module.
c. Remove screws (N) on bracket (K). Carefully remove the LED module (I) from
bracket (K),
d. Reverse steps a-c for installing the new LED module.
e. Note: The LED module should be provided by a specified supplier.
f. For better heat dissipation the LED module (I) should be applied with
thermal grease when re-lamping.
IMPORTANT: Fixture should be installed by a qualified electrician to
ensure proper wiring and installation.
Dimmable with C-L (CFL & LED) type and Incandescent/Halogen type dimmers