MEAN WELL RS-75 series 75W Single Output Switching Power Supply Instruction Manual
- June 4, 2024
- MEAN WELL
Table of Contents
MEAN WELL RS-75 series 75W Single Output Switching Power Supply Instruction
Manual
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105℃ long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70℃
- Withstand 5G vibration test
- No load power consumption<0.5W
- High efficiency, long life and high reliability
- 3 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx
SPECIFICATION
MODEL| RS-75-3.3| RS-75-5| RS-75-12| RS-75-15|
RS-75-24| RS-75-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 15A| 12A| 6A| 5A| 3.2A| 1.6A
CURRENT RANGE| 0 ~ 15A| 0 ~ 12A| 0 ~ 6A| 0 ~ 5A| 0 ~ 3.2A| 0 ~ 1.6A
RATED POWER| 49.5W| 60W| 72W| 75W| 76.8W| 76.8W
RIPPLE & NOISE (max.) **Note.2| 80mVp-p| 80mVp-p| 120mVp-p| 120mVp-p|
120mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 3V ~ 3.6V| 4.75 ~ 5.5V| 10.8 ~ 13.2V| 13.5 ~ 16.5V|
22 ~ 27.6V| 42 ~ 54V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full
load
HOLD UP TIME (Typ.)| 60ms/230VAC14ms/115VAC at full load
INPUT| VOLTAGE RANGE| 88 ~ 264VAC125 ~ 373VDC (Withstand 300VAC
surge for 5sec. Without damage)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 75%| 79%| 84.5%| 86%| 88.5%| 89.5%
AC CURRENT (Typ.)| 2A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| OVERLOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V|
27.6 ~ 32.4V| 55.2 ~ 64.8V
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
ENVIRONMENT| WORKING TEMP.| -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0~50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X,
Y, Z axes
****SAFETY & **EMC (Note 6)| SAFETY STANDARDS| UL62368-1, TUV
BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS| MTBF| 2918.8K hrs min. Telcordia SR-332 (Bellcore) ;
569.6K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 1299838mm (LWH)
PACKING| 0.41Kg; 30pcs/13.3Kg/0.86CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Line regulation is measured from low line to high line at rated load.
- Load regulation is measured from 0% to 100% rated load.
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies.(as available on http://www.meanwell.com)
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](https://www.meanwell.com/serviceDisclaimer.aspx)
Mechanical Specification
Terminal Pin No. Assignment
Pin No. | Assignment |
---|---|
1 | AC/l |
2 | AC/N |
3 | FG |
4 | DC OUTPUT -V |
5 | DC OUTPUT +V |
Block Diagram
Derating Curve
Output Derating VS Input Voltage
QR CODE
Documents / Resources
| MEAN
WELL RS-75 series 75W Single Output Switching Power
Supply
[pdf] Instruction Manual
RS-75 series 75W Single Output Switching Power Supply, RS-75 series, 75W
Single Output Switching Power Supply, Output Switching Power Supply, Switching
Power Supply, Power Supply, Supply
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>