- Features
- Applications
- GTIN CODE
- Description
- Model Encoding
- SPECIFICATION
- Block Diagram
- Derating Curve
- Static Characteristics
- Mechanical Specification
- Installation Manual
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL EPS-65S Series 65W Single Output Switching Power Supply
Features
- 3″×2″ miniature size
- Universal AC input / Full range
- ClassⅡ(without FG) installations
- No load power consumption<0.1W
- High efficiency up to 91%
- For 1U applications
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- 30~70℃wide range of operating temperature
- LED indicator for power on
- 3 years warranty
Applications
- Industrial electrical equipment
- Mechanical equipment
- Factory automation equipment
- Handheld electronic device
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
EPS-65S is a 65W highly reliable green PCB type industrial power supply with a high power density on the 3” by 2” footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 91% and the extremely low no load power consumption is down below 0.1W. EPS-65S is able to be used for ClassⅡ(no FG) system design.
Model Encoding
SPECIFICATION
ORDER NO.| EPS – 65S – 3. 3| EPS – 65S –
5| EPS – 65S – 7. 5| EPS – 65S – 12|
EPS – 65S – 15| EPS – 65S – 24| EPS – 65S –
48
---|---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 3.3V| 5V| 7.5V| 12V| 15V| 24V| 48V
RATED CURRENT| 10A| 10A| 8A| 5.42A| 4.34A| 2.71A| 1.36A
CURRENT RANGE| 0 ~ 11A| 0 ~ 11A| 0 ~ 8.8A| 0 ~ 5.96A| 0 ~ 4.77A| 0 ~
2.98A| 0 ~ 1.49A
RATED POWER| 33W| 50W| 60W| 65W| 65.1W| 65W| 65.3W
PEAK LOAD(10sec.) **Note.2| 36.3W| 55W| 66W| 71.5W| 71.6W|
71.5W| 71.5W
RIPPLE & NOISE (max.) Note.3| 80mVp-p| 80mVp-p| 80mVp-p|
120mVp-p| 150mVp-p| 240mVp-p| 300mVp-p
VOLTAGE ADJ.RANGE| 2.9~3.6V| 4.7~5.5V| 7.12~8.3V| 11.4~13.2V|
13.5~16.5V| 22.8~27.6V| 45.6~52.8V
VOLTAGE TOLERANCE Note.4| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±1.0%|
±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 500ms, 30ms / 230VAC 500ms, 30ms /
115VAC at full load
HOLD UP TIME (Typ.)**| 30ms / 230VAC 12ms / 115VAC at
full load
INPUT
| VOLTAGE RANGE **Note. 5| 80 ~ 264VAC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 80%| 84%| 85%| 88%| 89%| 90%| 91%
AC CURRENT (Typ.)| 1.5A / 115VAC 1A / 230VAC
INRUSH CURRENT (Typ.)| СOLD STAR 30A/115VAC 50A/230VAC
LEAKAGE CURRENT(max.)**| 0.25mA/264VAC
PROTECTION
| ****
OVERLOAD
| 115 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE
| 3.8~4.46V| 5.75~6.75V| 8.62~11.3V| 13.8~16.2V| 17.25~20.25V| 27.6~32.4V|
55.2~64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03% / ℃ (0 ~ 50℃)
OPERATING ALTITUDE Note.6| 5000 meters
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
(Note. 7)
| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368- 1, BS
EN/EN60335-1, CCC GB4943.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P: 3KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032(CISPR32) Class B, BS
EN/EN61000-3-2,3, GB9254.1 Class B,GB17625 Class A,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, Heavy industry Level , EAC TP TC 020
OTHERS
| MTBF| 3334.3K hrs min. Telcordia SR-332 (Bellcore) ; 706.6K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 76.250.824mm or 3″ 2″ 0.945″ inch (LWH)
PACKING| 0.11Kg; 120pcs/14.2Kg/0.94CUFT
NOTE
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power.
(as available on http://www.meanwell.com)
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Static Characteristics
Mechanical Specification
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/N | JST VHR |
or equivalent
| JST SVH-21T-P1.1
or equivalent
2| No Pin
3| AC/L
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | +V |
JST VHR
or equivalent
|
JST SVH-21T-P1.1
or equivalent
2| +V
3| -V
4| -V