Features

  • Full power output at 70~100% constant current range operation
  • Wide input range 90 ~ 305VAC with active PFC function
  • Metal housing design with IP67
  • Multiple dimming functions: 3 in 1 (0-1 0V/PWM/Resistor)
  • Dimming circuit with Isolated for latest safety regulation
  • Surge protection with 6KV/4KV
  • Typical lifetime>50000 hours and 5 years warranty
  • AC input cable with connector for flexible installation

Features
Features

Applications

  • LED bay lighting
  • LED stage lighting
  • LED spot lighting
  • Explosion-proof lighting
  • Type HL LED driver for class I division 2.

Description

XBG-100 series is a 1 00W AC/DC LED driver featuring the constant power mode. XBG-100 operates from 90~305VAC and offers with different rated current ranging between 1750mA and 2780mA. Thanks to the high efficiency up to 92%, with the fanless design, the entire series is able to operate for -40°C~+85°C case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments. XBG-100 series comply with the latest version of IEC61347/IEC60598-1 and UL8750 international safety regulations.The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both users and luminaire system during installation.

Model Encoding

Model Encoding

Type IP Level Function Note
A IP67 constant power adjustable via built-in potentiometer In Stock
AB IP67 constant power adjustable via built-in potentiometer+ 3 in 1 dimming
function (0~1 0Vdc, 10V PWM signal and resistor) In Stock

SPECIFICATION

MODEL G-100-
OUTPUT DEFAULT CURRENT
RATED POWER 100W
CONSTANT CURRBS EN/ENT REGION 27 – 56V
FULL POWER CURRENT RANGE 1750-2780mA
OPEN CIRCUIT VOLTAGE (max.) 60V
CURRENT ADJ. RANGE 875-2780mA
CURRENT RIPPLE 3.0% max. @rated current
CURRENT TOLERANCE ±5%
SET UP TIME Note.4
INPUT VOLTAGE RANGE

refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 – 63Hz
POWER FACTOR (Typ.)| PF 0.97 / 115VAC, PF 0.95 / 230VAC, PF 0.92 / 277VAC at full load (Please refer to “Power Factor Characteristic” section)
TOTAL HARMONIC DISTORTION| THD< 10% (@ load2 50% at 115VAC/230VAC ,@ load2 75% at 277VAC) Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
EFFICIENCY (Typ.)| 92%
AC CURRENT (Typ.)| 1.1A/115VAC
0.5A/ 230VAC
0.42A/ 277VAC
INRUSH CURRENT(Typ.)| ()OLD START 50A(twidth=400 s measured at 50% Ipeak) at 230VAC; Per NEMA410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER| 8 unit(circuit breaker of type B) / 14 units(circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA/ 277VAC
STANDBY POWER CONSUMPTION| Standby power consumption<0.5W for AB- Type
PROTECTION| OVERPOWER| 105-150%
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT| Constant current limiting or Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 61 – 78V
Shut down output voltage, re-power on after fault condition is removed to recover
OVER TEMPERATURE| Shut down output voltage, re-power on after fault condition is removed to recover
ENVIRONMENT| WORKING TEMP.| Tcase=-40 – +85’C (Please refer to “OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+85″C
WORKING HUMIDITY| 20 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +80°C, 10 – 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/°C (0-60°C)
VIBRATION| 10- 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| UL8750(type”HL”), CSAC22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; IS15885(Part2/Sec13); GB19510.1,GB19510.14; IP67;EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
I/P-PE:2KVAC
O/P-PE:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-PE, O/P-PE:1 QOM Ohms/ 500VDC / 25″C/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level/Note
Conducted| BS EN/EN55015(CISPR15) ,GB /T17743| —–
Radiated| BS EN/EN55015(CISPR15) ,GB /T1774 3| —–
Harmonic Current| BS EN/EN61000-3- 2,GB/T 17625 .1| Class C @load;o,50%
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61547
Parameter| Standard| Test Level/Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT/Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| 4KV/Line-Line 6KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods, m>95% interruptions 250 periods
OTHERS| MTBF| 727.29K hrs min. Telcordia SR-332(Bellcore) ;188.SK hrs min. MIL-HDBK-217F (25°C)
LIFETIME| Note.5| 50000 hrs min.
DIMENSION| qJ 130mm ’56mm(D’H)
PACKING| 0.8Kg; 16pcs/ 14.8Kg/1.57CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25″C of ambient temperature.
  2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
  3. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
  4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  5. This series meets the typical life expectancy of >50,000 hours of operation when Tease, particularly tc point (or TMP, per DLC), is about 75″C or less.
  6. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED drive can only be used behind a switch without permanently connected to the mains.
  7. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
  8. The ambient temperature derating of 3SC/1000m with fanless models and of 5’C/1000m with fan models for operating altitude higher than 2000m(6500ft).
  9. Products sourced from the Americas regions may not have the PSE/CCC/BIS/KC logo. Please contact your MEAN WELL sales for more information.
  10. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
    Product Liability Disclaimer : For detailed information please refer to httos://www.meanwell.com/serviceDisclaimer.asox

File Name:XBG-100-SPEC 2021-12-06

BLOCK DIAGRAM

Block Diagram

DRIVING METHODS OF LED MODULE

  • V Operating Area
    • XBG-100
      Driving Methods Of Led Module

DIMMING OPERATION

Dimming Operation

3 in 1 dimming function (for AB-Type)

  • Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 – 1 0VDC, or 1 0V PWM signal or resistance.

  • Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.

  • Dimming source current from power supply: 1 00μA (typ.)

    • Applying additive 0 – 1 0VDC
      Dimming Operation
      Dimming Operation

    • Applying additive 10V PWM signa l (frequency range 1 00Hz – 3KHz):
      Dimming Operation
      Dimming Operation

    • Applying additive resistance:
      Dimming Operation
      Dimming Operation

Note:

  1. Min. dimming level is about 8% and the output current is not defined when 0%< Tout<8%.
  2. The output current could drop down to 0% when dimming input is about 00 or 0Vdc, or 1 0V PWM signa l with 0% duty cycle.

OUTPUT LOAD vs TEMPERATURE

Output Load Vs Temperature

STATIC CHARACTERISTIC

Static Characteristic

POWER FACTOR PF CHARACTERISTIC

  • Tease at 65°C
    Power Factor \(Pf\) Characteristic

TOTAL HARMONIC DISTORTION (THD)

  • 1750mA Model, Tease at 65°C
    Total Harmonic Distortion \(Thd\)

EFFICIENCY vs LOAD

  • XBG-100 series possess superior working efficiency that up to 92% can be reached in fie ld applications.
  • 1750mA Model, Tease at 65°C
    Efficiency Vs Load

LIFE TIME

Life Time

INSTALLATIONS

| |
---|---|---
Hanger| Chain| High Bay Light

Caution

  • Please inspect the appearance of the driver if the package is damaged. There should not be any cracks.
  • Please do not drop or bump the driver.
  • All screws including the suspension screw should be paired with a spring washer and locked tight.
  • The entire luminaire , including the driver, should be limited to 10Kg or less.
  • The luminaire should be cautiously protected from damage due to shock throughout packaging and transportation.
  • Please thoroughly follow the preceding cautionary notes to prevent the luminaire from falling, leading to injuries.

MECHANICAL SPECIFICATION

  • A-Type(AC Cable with fixed cable)
    Mechanical Specification

  • AB-Type(AC Cable with fixed cable
    Mechanical Specification

  • :Max. Case Temperature.(case temperature measured point)

  • Ta: Ambient Temperature measured point

  • A-C-Type(AC cable with connector)
    Mechanical Specification

  • AB-C-Type(AC cable with connector)
    Mechanical Specification

Terminal Pin No.Assignment(CHOGORI 22003515-01)

Pin No. Ass ignment Draw ing
1 AC/L
2 AC/N
3 PE
  • Max.Case Temperature.(case temperature measured point)
  • Ta: Ambient Temperature measured point

AC input cable option

Item Order part NO.
1M 1FF5XBG-160- IP1
2M 1FF5XBG- 160- IP2
3M 1FF5XBG-160- IP3

Mechanical Specification

 INSTALLATION MANUAL!

Please refer to: http://www.meanwell.com/manual.html

QR Code

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals