Features
- Wide input range 90 ~ 305VAC
- Full power at 60~100% max current (Constant Power)
- Built-in active PFC function
- Circular metal housing design with IP67
- Function options: output adjustable via potentiometer; 3 in 1 dimming (Dim to off and Isolation) ; DALl-2 dimming
- Typical lifetime>50000 hours
- 5 years warranty
Applications
- Bay lighting
- Stage lighting
- Flood lighting
- Stadium lighting
- Type HL for use in class I ,Division 2
Description
HBGC-300 series is a 300W LED AC/DC driver featuring the constant power mode and high voltage output. HBGC-300 operates from 90~305VAC and offers models with different rated current ranging between 1300mA and 8670mA. Thanks to the high efficiency up to 94.5%, with the fanless design, the entire series is able to operate for -40°C~+80°C case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. HBGC-300 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
Type | IP Level | Function | Note |
---|---|---|---|
A | IP67 | output constant power adjustable via built-in potentiometer | In Stock |
AB | IP67 | output constant power adjustable via built-in potentiometer 3 in 1 | |
dimming function (0~1 0Vdc, 10V PWM signal and resistance) | In Stock | ||
ADA | IP67 | DALl-2 control technology with lo Adjustable via build-in | |
Potentiometer | In Stock |
SPECIFICATION
MODEL | HBGC-300-LO | HBGC-300-MO | HBGC-300-HO |
---|---|---|---|
OUTPUT | DEFAULT CURRENT | 1400mA | 2800mA |
RATED POWER | 301.6W | 301.6W | 301.6W |
CONSTANT CURRENT REGION | 116-232V | 58-116V | 29- 58V |
FULL POWER CURRENT RANGE | 1300-2170mA | 2600-4330mA | 5200-8670mA |
OPEN CIRCUIT VOLTAGE (max.) | 240V | 120V | 62V |
CURRENT ADJ. RANGE | 650-2170mA | 1300-4330mA | 2600-8670mA |
CURRENT RIPPLE | 5.0% max. @rated current | ||
CURRENT TOLERANCE | ±5% | ||
SET UP TIME | 500ms/230VAC, 500ms/115VAC |
INPUT
| VOLTAGE RANGE Note.2| 90- 305VAC 127VDC-431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 – 63Hz
POWER FACTOR (Typ.)| PF 0.97 / 115VAC, PF 0.95 / 230VAC, PF 0.92 /
277VAC at full load (Please refer to “Power Factor Characteristic” section)
TOTAL HARMONIC DISTORTION| THO< 10% (@load 50% at 115VAC/230VAC ,@load
75% at 277VAC) Please refer to “TOTAL HARMONIC DISTORTION (THO)” section
EFFICIENCY (Typ.)| 94.5%| 93.5%| 92.5%
AC CURRENT (Typ.)| 3A/ 115VAC 1.6A/ 230VAC 1.3A/ 277VAC
INRUSH CURRENT(Typ.)| COLD START 45A (t width=1300µs measured at 50%
Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER| ****
2 unit(circuit breaker of type B) / 4 units(circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA/ 277VAC
NO LOAD/ STANDBY POWER CONSUMPTION| Standby power consumption <0.5W for
AB/ ADA-Type Blank/A-Type please refer to Note. 5
PROTECTION| SHORT CIRCUIT| Constant current limiting, recovers
automatically after fault condition is removed
OVER VOLTAGE| 241 -275V| 121 -145V| 61 – 78V
Shut down output voltage, re-power on to recovery
OVER TEMPERATURE| Tcase>BO”C ±5″C,derate power automatically by 6°/JC
max.
ENVIRONMENT| WORKING TEMP.| Tcase=-40 – +80’C(Please refer to
“OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+80″C
WORKING HUMIDITY| 20 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +B0″C , 1O – 95% RH non-condensing
TEMP. COEFFICIENT| ± 0.03%/°C (0 – 60°C)
VIBRATION| 10-500Hz, 5G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| UL8750(type”HL”), CSA C22.2 No.
250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS
EN/EN62384; EAC TP TC 004;GB19510.1 , GB19510.14; IP67 approved
DALI STANDARDS| Compliance to IEC62386-101, 102,207 for ADA Type only
WITHSTAND VOLTAGE| I/P-0/P 3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-0 /P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25″C/
70% RH
EMC EMISSION| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@
load 50%); BS EN/EN61000-3-3,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line
4KV), EAC TPTC 020
OTHERS
| MTBF| 561.2K hrs min. Telcordia SR-332(Bellcore); 154.9K hrs min.
MIL-HDBK-217F (25″C)
LIFETIME Note.4| 50000 hrs min.
DIMENSION| rp 191.5mm ’69mm
PACKING| 2.2Kg;Bpcs/19 .8Kg/2.09CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25°C of ambient temperature.
- De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- This series meets the typical life expectancy of >50,000 hours of operation when Tease, particularly tc point (or TMP, per DLC), is about 75″C or less.
- To fulfill requirements of the latest ErP regulation for lighting fixture, this LED drive can only be used behind a switch without permanently connected to the mains.
- Please refer to the warranty statement on MEAN WELL’s website at http: / /www.meanwell.com
- The ambient temperature derating of 3.5°C/ 1000m with fanless models and of 5°C /1000m with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
BLOCK DIAGRAM
PFC KH fosc : 45~50 z
PWM KH fosc : 60~130 z
DRIVING METHODS OF LED MODULE
※ I V Operating Area –
-
HBGC-300-L
-
HBGC-300-M
-
HBGC-300-H
DIMMING OPERATION
※ 3 in 1 dimming function (for AB-Type)
-
Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:
0 ~ 10VDC, or 10V PWM signal or resistance. -
Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
-
Dimming source current from power supply: 100 A (typ.)
Applying additive 0 ~ 10VDC
Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
Applying additive resistance:
Note :
- Min. dimming level is about 8% and the output current is not defined when 0%< out<8%. I
- The output current could drop down to 0% when dimming input is about 0k or 0Vdc, or 10V PWM signal with 0% duty cycle.
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
※ Tcase at 65℃
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
HBGC-300 series possess superior working efficiency that up to 94.5% can be reached in field applications.
※ HBGC-300-L Model, Tcase at 65℃
LIFE TIME
MECHANICAL SPECIFICATION
- : Max. Case Temperature.(case temperature measured point)
- Ta: Ambient Temperature measured point
- : Max. Case Temperature.(case temperature measured point)
- Ta: Ambient Temperature measured point
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>