Features

  • Universal AC input / Full range
  • Adjustable output voltage and current level
  • Protections: Short circuit / Over current / Over voltage/ Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Fully isolated plastic case with terminal block style of I/O
  • Built-in active PFC function, comply with BS EN/EN61000-3-2 class C (Pin≥25W)
  • Class II power unit, no FG
  • Class 2 power unit
  • 100% full load burn-in test
  • High reliability
  • Suitable for LED lighting and moving sign applications (Note.2)
  • Compliance to worldwide safety regulations for lighting
  • 2 years warranty

MEAN-WELL-PLC-30-9-Single-Output-LED-Power-Supply-With-PFC-
FIG-9

User’s Manual

MEAN-WELL-PLC-30-9-Single-Output-LED-Power-Supply-With-PFC-
FIG-8

SPECIFICATION

MODEL| PLC-30-9| PLC-30-12| PLC-30-15| PLC-30-20| PLC-30-24| PLC-30-27| PLC-30-36| PLC-30-48
---|---|---|---|---|---|---|---|---

OUTPUT

| DC VOLTAGE| 9V| 12V| 15V| 20V| 24V| 27V| 36V| 48V
CONSTANT CURRENT REGION Note.6| 6.3 ~ 9V| 8.4 ~ 12V| 10.5 ~ 15V| 14 ~ 20V| 16.8 ~ 24V| 18.9 ~ 27V| 25.2 ~ 36V| 33.6 ~ 48V
RATED CURRENT| 3.3A| 2.5A| 2A| 1.5A| 1.25A| 1.12A| 0.84A| 0.63A
CURRENT RANGE| 0 ~ 3.3A| 0 ~ 2.5A| 0 ~ 2A| 0 ~ 1.5A| 0 ~ 1.25A| 0 ~ 1.12A| 0 ~ 0.84A| 0 ~ 0.63A
RATED POWER| 29.7W| 30W| 30W| 30W| 30W| 30.24W| 30.24W| 30.24W
RIPPLE & NOISE (max.) **Note.2| 2.6Vp-p| 2Vp-p| 2.6Vp-p| 2.6Vp-p| 2.4Vp-p| 2.3Vp-p| 3.6Vp-p| 3.7Vp-p
VOLTAGE ADJ. RANGE Note.5| 8.55 ~ 9.9V| 11.4 ~ 13.2V| 14.5 ~ 16.5V| 19 ~ 22V| 22.8 ~ 26.4V| 25.65 ~ 29.7V| 34.2 ~ 39.6V| 45.6 ~ 52.8V
CURRENT ADJ. RANGE Note.5| 2.475 ~ 3.399A| 1.875 ~ 2.575A| 1.5 ~ 2.06A| 1.125 ~ 1.545A| 0.938 ~ 1.288A| 0.84 ~ 1.1536A| 0.63 ~ 0.865A| 0.473 ~ 0.649A
VOLTAGE TOLERANCE Note.3| ±10%
LINE REGULATION| ±3.0%
LOAD REGULATION| ±5.0%
SETUP TIME**| 500ms / 230VAC  3000ms / 115VAC at full load

INPUT

| VOLTAGE RANGE Note.4| 90 ~ 264VAC             127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/115VAC, PF>0.9/230VAC at full load (Please refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION| THD< 20% when output loading≧70% at 115VAC/230VAC input
EFFICIENCY (Typ.)| 80%| 82.5%| 83.5%| 84%| 84%| 84.5%| 85%| 85.5%
AC CURRENT (Typ.)| 0.4A/115VAC  0.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 35A(twidth=25μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.5mA / 240VAC

PROTECTION

| OVER CURRENT| 100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE| 10 ~ 14V| 14 ~ 17V| 17 ~ 22V| 23 ~ 26V| 27 ~ 34V| 31 ~ 35V| 40 ~ 50V| 53 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover

ENVIRONMENT

| WORKING TEMP.| -30 ~ +50℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.06%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

| SAFETY STANDARDS| UL1310, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, GB19510.14,GB19510.1, CAN/CSA C22.2 No. 223-M91(except for 48V),

EAC TP TC 004 approved

WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55015, GB17743, GB17625.1,BS EN/EN61000-3-2 Class C (Pin≧25W), Class D (>70% load) ;

BS EN/EN61000-3-3,EAC TP TC 020

EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61547, light industry level, criteria A,EAC TP TC 020

OTHERS

| MTBF| 625.5Khrs min.  MIL-HDBK-217F (25℃)
DIMENSION| 1604630mm (LWH)
PACKING| 0.2Kg; 70pcs/15Kg/0.96CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.

  3. Tolerance : includes set up tolerance, line regulation and load regulation.

  4. Derating may be needed under low input voltage. Please check the static characteristics for more details.

  5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.

  6. Please refer to “DRIVING METHODS OF LED MODULE”.

  7. The power supply is considered as a component that will be operated in combination with final equipment. Since MC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify MC Directive on the complete installation again.

  8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.

  9. To fulfill requirements of the latest Er regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.

  10. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft.

  11. PLC-30-9 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be
    use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling, traffic control or airfield lamps).

  12. Product Liability Disclaimer: For detailed information, please refer to httos://www.meanwell.com/serviceDisclaimer.aspx File Name:PLC-30-SPEC 2021-12-

Mechanical Specification

MEAN-WELL-PLC-30-9-Single-Output-LED-Power-Supply-With-PFC-
FIG-1

Block Diagram

MEAN-WELL-PLC-30-9-Single-Output-LED-Power-Supply-With-PFC-
FIG-2

Derating Curve

MEAN-WELL-PLC-30-9-Single-Output-LED-Power-Supply-With-PFC-
FIG-3

Static Characteristics

Power Factor Characteristic

MEAN-WELL-PLC-30-9-Single-Output-LED-Power-Supply-With-PFC-
FIG-5

EFFICIENCY VS LOAD (48V Model)

  • PLC-30 series possess superior working efficiency that up to 85.5% can be reached in field applications.

DRIVING METHODS OF LED MODULE

This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.

  • In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.