MEAN WELL PLC-30-9 Single Output LED Power Supply With PFC Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
- MEAN WELL PLC-30-9 Single Output LED Power Supply With PFC
- Features
- SPECIFICATION
- Mechanical Specification
- Block Diagram
- Derating Curve
- Static Characteristics
- Power Factor Characteristic
- EFFICIENCY VS LOAD (48V Model)
- DRIVING METHODS OF LED MODULE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL PLC-30-9 Single Output LED Power Supply With PFC
Features
- Universal AC input / Full range
- Adjustable output voltage and current level
- Protections: Short circuit / Over current / Over voltage/ Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- Fully isolated plastic case with terminal block style of I/O
- Built-in active PFC function, comply with BS EN/EN61000-3-2 class C (Pin≥25W)
- Class II power unit, no FG
- Class 2 power unit
- 100% full load burn-in test
- High reliability
- Suitable for LED lighting and moving sign applications (Note.2)
- Compliance to worldwide safety regulations for lighting
- 2 years warranty
User’s Manual
SPECIFICATION
MODEL| PLC-30-9| PLC-30-12| PLC-30-15| PLC-30-20|
PLC-30-24| PLC-30-27| PLC-30-36| PLC-30-48
---|---|---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 9V| 12V| 15V| 20V| 24V| 27V| 36V| 48V
CONSTANT CURRENT REGION Note.6| 6.3 ~ 9V| 8.4 ~ 12V| 10.5 ~
15V| 14 ~ 20V| 16.8 ~ 24V| 18.9 ~ 27V| 25.2 ~ 36V| 33.6 ~ 48V
RATED CURRENT| 3.3A| 2.5A| 2A| 1.5A| 1.25A| 1.12A| 0.84A| 0.63A
CURRENT RANGE| 0 ~ 3.3A| 0 ~ 2.5A| 0 ~ 2A| 0 ~ 1.5A| 0 ~ 1.25A| 0 ~
1.12A| 0 ~ 0.84A| 0 ~ 0.63A
RATED POWER| 29.7W| 30W| 30W| 30W| 30W| 30.24W| 30.24W| 30.24W
RIPPLE & NOISE (max.) **Note.2| 2.6Vp-p| 2Vp-p| 2.6Vp-p| 2.6Vp-p|
2.4Vp-p| 2.3Vp-p| 3.6Vp-p| 3.7Vp-p
VOLTAGE ADJ. RANGE Note.5| 8.55 ~ 9.9V| 11.4 ~ 13.2V| 14.5 ~ 16.5V|
19 ~ 22V| 22.8 ~ 26.4V| 25.65 ~ 29.7V| 34.2 ~ 39.6V| 45.6 ~ 52.8V
CURRENT ADJ. RANGE Note.5| 2.475 ~ 3.399A| 1.875 ~ 2.575A| 1.5 ~
2.06A| 1.125 ~ 1.545A| 0.938 ~ 1.288A| 0.84 ~ 1.1536A| 0.63 ~ 0.865A| 0.473 ~
0.649A
VOLTAGE TOLERANCE Note.3| ±10%
LINE REGULATION| ±3.0%
LOAD REGULATION| ±5.0%
SETUP TIME**| 500ms / 230VAC 3000ms / 115VAC at full load
INPUT
| VOLTAGE RANGE Note.4| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/115VAC, PF>0.9/230VAC at full load (Please
refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION| THD< 20% when output loading≧70% at
115VAC/230VAC input
EFFICIENCY (Typ.)| 80%| 82.5%| 83.5%| 84%| 84%| 84.5%| 85%| 85.5%
AC CURRENT (Typ.)| 0.4A/115VAC 0.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 35A(twidth=25μs measured at 50% Ipeak)
at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 64 units (circuit breaker of
type B) / 64 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.5mA / 240VAC
PROTECTION
| OVER CURRENT| 100 ~ 110%
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition
is removed.
OVER VOLTAGE| 10 ~ 14V| 14 ~ 17V| 17 ~ 22V| 23 ~ 26V| 27 ~ 34V| 31 ~
35V| 40 ~ 50V| 53 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
ENVIRONMENT
| WORKING TEMP.| -30 ~ +50℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.06%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC
| SAFETY STANDARDS| UL1310, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, GB19510.14,GB19510.1, CAN/CSA C22.2 No. 223-M91(except for 48V),
EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55015, GB17743, GB17625.1,BS
EN/EN61000-3-2 Class C (Pin≧25W), Class D (>70% load) ;
BS EN/EN61000-3-3,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61547, light industry level, criteria A,EAC TP TC 020
OTHERS
| MTBF| 625.5Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 1604630mm (LWH)
PACKING| 0.2Kg; 70pcs/15Kg/0.96CUFT
NOTE
-
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
-
Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
-
Tolerance : includes set up tolerance, line regulation and load regulation.
-
Derating may be needed under low input voltage. Please check the static characteristics for more details.
-
Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
-
Please refer to “DRIVING METHODS OF LED MODULE”.
-
The power supply is considered as a component that will be operated in combination with final equipment. Since MC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify MC Directive on the complete installation again.
-
Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
-
To fulfill requirements of the latest Er regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
-
The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft.
-
PLC-30-9 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be
use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling, traffic control or airfield lamps). -
Product Liability Disclaimer: For detailed information, please refer to httos://www.meanwell.com/serviceDisclaimer.aspx File Name:PLC-30-SPEC 2021-12-
Mechanical Specification
Block Diagram
Derating Curve
Static Characteristics
Power Factor Characteristic
EFFICIENCY VS LOAD (48V Model)
- PLC-30 series possess superior working efficiency that up to 85.5% can be reached in field applications.
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
- In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.
- Should there be any compatibility issues, please contact MEAN WELL.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>