MEAN WELL AD-155A 155W Single Output with Battery Charging UPS Function Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
MEAN WELL AD-155A 155W Single Output with Battery Charging UPS Function
Features
- Universal AC input/ Full range
- Protections: Short circuit I Overload; Over voltage
- Battery low and battery polarity protection
- Cooling by free air convection
- 100% full load burn-in test
- Fixed switching frequency at PFC 67KHz. PWM 134KHz
- Optional DIN Rail Attachment
SPECIFICATION
MODEL | AD155-A | AD155-B | AD1 55-C |
---|---|---|---|
OUTPUT | OUTPUTNUMBER | CH1 | CH2 |
DC VOLTAGE | 13.8V | 13.3V | 27.6V |
RATED CURRENT | 10.5A | 0.5A | 5A |
0-0.5A
| 2.7A
0- 2.7A
| 0.2A
0 – 0.5A
CURRENTRANGE| 0 – 11.5A| 0 – 0.5A| 0-55A
RATED POWER| 151.55W| 151.55W| 156.55W
RIPPLE& NOISE(max.)
Note.,| 15-0tm/p-p| —| 150mVp-p| —-| 240mVp-p| —
VOLTAGEADJ. RANGE| CH1: 12- 14.5V| CH1 : 24 -29V| CH1 : 48-58V
VOLTAGETOLERANCE
Note.3LINEREGULATION| ±2.0%
±0.5%
| — —
— —
| ±1.0%
±0.5%
| – —
——
| ±1.0%
±0-.5%
| —
—-
LOAD REGULATION| ±o.5%| – –| ±0.5%| — —| ±o.5%| —
SETU,PRISE TIME| 1OOOms, 90ms/230VAC 2000ms, 90ms/115VACat full load
HOLD UP TIME (Typ,)| 24ms/230VAC 2oms115VACat ru11 l o ad
INPUT| VOLTAGE RANGE
FREQUENCYRANGE| 88 – 264VAC 124- 370VDC
47 – 63Hz
POWER FACTOR
( Typ.)| PF>0.92at lull load
EFFICIENCY(Typ)| 80%| | 84%
ACCURRENT(Typ.)| 2.5A/115VAC 1.5A/230VAC|
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT| COLD START 23A1115VAC 45A/’230VAC
<1mA/24 0VAC
|
PROTFCTION| OVERLODA| CH1:105- 135% CH2:0.51 -0.9Arated output power| |
Protection Type : AC Charging Mode : Constant current limiting, recover
automatically after fault condition is removed UPS Mode :
Protected by Internal fuse
OVERVOLTAGE
BATTERYLOW| CH1:1 .87- 18.G3V| CH1:31.74- 37.26V| CH1G: 2.1- 72.9Y
Protection Type : Shut down O/P voltage, e re-power on to recover
10VJ:0.8 V f1 9.5V(+1.5V-1,V) 39V±2V
ENVIRONMENT| WORKINGTEMP.| -10 – +60ºC (Refer lo “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEM.P, HUMIDITY| -20- +85-ºC, 10 – 95%RH
TEMP. COEFFICIETN| ±o 03%FC (0 – 50ºC)|
VIBRATION| 10- 500Hz. 2G10mni .11cycle,60min.each along X. Y. Z axes
SAFETY & EMC (Note4)| SAFETY STANDARDS| UL62368-1, TW esENIEN62368-1A, SINZS
62368.1, EAC TPTC 004 approved
WITHSTANDVOLTAGE| IIP-OIP:3KVAC 1/P-F G:1.SKYAC 0/P-FG:O.SKYAC
ISOLATION RESISTANCE| IIP-0/ P, I/P-FG, 0/P-FG:1OOM Ohms/ 500VDCI 25″C/ 70%RH
EMCEMISSION
EMCIMMUNITY| Compliance to BSEN/EN5S032 (CISPR32)Class
B,BSEN/EN61000-3-2,-3,EAC TP TC 020
Compliance to BS EN/EN6100-4-2.3.4.5.6.8.11. esENIENS5024. light industry
level. criteria A EAC TP TC020
OTHERS| MTBF| 183.3Khr min. MIL-HDBK-217F /25’CI
DIM ENSION| 199•110•50,nm (L-w-H)
PACKING| 0,88Kg; 11pi CS/15Kg/0.9oCUFI
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
Mechanical Specification
Terminal Pin No. Assignment
Pi n No .
1| Assignment
AC/L| Pin No .
5| Assignment
BAT+
---|---|---|---
2| AGIN| 6| BAT. -/COM
3| FG| 7| DC OUTPUTCOM
4| NC| 8| DCOUTPUT+V
CN1 Pin No. Assignment :JST B2B-XH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | RESET SW | JST XHP or equivalent | JST SXH-001T-P0.6 or equivalent |
2
Block Diagram
Derating Curve
Output Derating VS Input Voltage (A)
OPTIONAL DIN RAIL MOUNTING KIT
SIMPLY ADD THE SUFFIX “/DRL” TO THE END OF THE MODEL NUMBER. I.E.