OPERATING INSTRUCTIONS
AM-86X65 ANALOGUE PANEL METER
- ITEM NO.: 103069 100 μA/DC
- ITEM NO.: 103070 100 mA/DC
- ITEM NO.: 103071 1 mA/DC
INTENDED USE
The analogue panel meters are designed for installation in switch cabinets or display panels and are only suitable for DC measurements. The installation occurs directly without external components; appropriate pre-resistors are already integrated in the circuit. Only in integrated status they may be put into operation. The suitable regulations are to be observed. The fixed measuring instruments are available with different measurement ranges. The scale needle can be adjusted precisely with the front screw. For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product for purposes other than those described above, the product may be damaged. In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc. Read the instructions carefully and keep them. Make this product available to third parties only together with its operating instructions. This product complies with the statutory national and European requirements. All company names and product names are trademarks of their respective owners. All rights reserved.
DELIVERY CONTENT
- Meter
- Mounting material
- Operating instructions
LATEST PRODUCT INFORMATION
Download the latest product information at www.conrad.com/downloads or scan
the QR code shown. Follow the instructions on the website.
SAFETY INSTRUCTIONS
Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.
Persons / Product
- The device must not be used in damp interiors or outdoors in the open air.
- The fixed measuring instrument must not be used for medical purposes.
- Be especially cautious in dealing with voltage >35 V/DC. Already at this voltage you can get a life-threatening electric shock when touching electric lines.
- De-energise the electric system before installing the measuring instrument.
- The device is not a toy. Keep it out of the reach of children and pets.
- Do not leave packaging material lying around carelessly. These may become dangerous playing material for children.
- Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity, moisture, flammable gases, vapours and solvents.
- Do not place the product under any mechanical stress.
- If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
- Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.
- Also observe the safety and operating instructions of any other devices which are connected to the product.
Miscellaneous
- Consult an expert when in doubt about operation, safety or connection of the device.
- Maintenance, modifications and repairs are to be performed exclusively by an expert or at a qualified shop.
If you are not sure about the correct connection or use, or if questions arise which are not covered by these operating instructions, please do not hesitate to contact our technical support or another qualified specialist.
EXPLANATIONS OF SYMBOLS
At the scale’s face different symbols are attached, that have the following significance:
INSTALLATION
Assembly and installation may only be carried out by a specialist, who is familiar with the relevant regulations and the ensuing risks. Mount the measuring instrument with the assembly material included in a pre-assembled rectangular front panel opening. Carefully attach the fixed measuring instrument. You can get the corresponding dimensions (in mm) from the following sketch.
CONNECTION
In order to ensure a correct start of operation, you should read these operating instructions including the safety instructions thoroughly and attentively before using the device. Do not connect when the wires are live. Connection of the panel meter has to be done in series connection. Connect the panel meter to the screwtype terminals on the back.
DISPOSAL
This symbol must appear on any electrical and electronic equipment placed on the EU market. This symbol indicates that this device should not be disposed of as unsorted municipal waste at the end of its service life. Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose of it separately from unsorted municipal waste. Spent batteries and accumulators, which are not enclosed by the WEEE, as well as lamps that can be removed from the WEEE in a non-destructive manner, must be removed by end users from the WEEE in a non-destructive manner before it is handed over to a collection point. Distributors of electrical and electronic equipment are legally obliged to provide free take-back of waste. Conrad provides the following return options free of charge (more details on our website):
- in our Conrad offices
- at the Conrad collection points
- at the collection points of public waste management authorities or the collection points set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of. It should be noted that different obligations about the return or recycling of WEEE may apply in countries outside of Germany.
TECHNICAL DATA
Item no.: | 103069 | 103070 | 103071 |
---|
Measurement range
(full-scale deflection):
| 100 µA/DC| 100 mA/DC| 1 mA/DC
Internal resistance:| approx. 2.6 kΩ| approx. 7 Ω| approx. 290 Ω
- Movement……………………………………….Moving coil
- Accuracy class…………………………………2.0
- Installation-Ø…………………………………..45 mm
- Operating conditions…………………………-25 to +55 °C, 20 – 95 % RH (non-condensing)
- Storage conditions……………………………-40 to +70 °C, 20 – 95 % RH (non-condensing)
- Weight……………………………………………approx. 65 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represents the technical status at the time of printing.