VIVO STAND-V001OU Pneumatic Arm Single Monitor Desk Mount With USB Instruction Manual

June 13, 2024
Vivo

VIVO STAND-V001OU Pneumatic Arm Single Monitor Desk Mount With USB

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-
PRODUCT

Product Information

Product Name Pneumatic Arm Single Monitor Desk Mount with USB
Model Number STAND-V001OU
Manufacturer VIVO
Website https://vivo-us.com/products/stand-v001ou
Contact Information Email: help@vivo-us.com

Phone: 309-278-5303
Live Chat: www.vivo-us.com
Weight Capacity| 4.4-19.8lbs (2-9kg)

Product Usage Instructions
Step 1 – Clamp Installation

  1. Remove the USB Cover (C1) from the Base (C).
  2. Adjust the hand bolt completely down on the Lower Clamp (D).
  3. Install the Upper Clamp (E) to the Base (C) using M6x8mm Screws (S-A) and the 5mm Allen Wrench (T-A).
  4. Reinstall the USB Cover (C1) onto the Base (C) using the ST3x8mm Screws (S-D) and the Phillips end of the 5mm Allen Wrench (T-A).
  5. Attach the Lower Clamp (D) to the top two holes on the Upper Clamp (E) using M6x10mm Screws (S-B) and the 4mm Allen Wrench (T-B). Secure the clamp assembly to the desktop.

Step 1 – Grommet

If your desktop does not have a preexisting grommet hole, use a 10mm drill bit to create one by drilling completely through the desktop.

  1. Secure the plastic shroud to the Base (C) using ST3x8mm Screws (S-D) and the Phillips end of the 5mm Allen Wrench (T-A).
  2. Disassemble the Lower Clamp (D) using the Phillips end of the 5mm Allen Wrench (T-A) and separate the Hand Bolt (D1).
  3. Place the Grommet Plate (F) on the Hand Bolt (D1) and secure the Base (C) to the desktop.

Step 2
Place the Lower Arm (A) onto the Base (C), then place the Upper Arm (B) onto the Lower Arm (A). Tighten the set screws using the flathead end of the 4mm Allen Wrench (T-B).

Step 3
Attach the VESA Plate (G) to the Upper Arm (B) using the M8x30mm Screw (S-C) and the 5mm Allen Wrench (T-A).

Step 4

  1. Install two Screws (M-A or M-B) and M5 Washers (M-C) using the Phillips end of the 5mm Allen Wrench (T-A) to the top VESA holes on the monitor, leaving at least 3mm of clearance between the screw and monitor.
  2. Slide the monitor onto the VESA Plate (G), making sure the screws sit within the slots.
  3. Tighten the top two screws and install the remaining Screws (M-A or M-B) and 5mm Washers (M-E) using the Phillips end of the 5mm Allen Wrench (T-A).

Scan the QR code with your mobile device or follow the link for helpful videos and specifications related to this product.

Instruction Manual
https://vivo-us.com/products/stand-v001ou

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(2\)

GET IN TOUCH
Monday-Friday from 7:00 am-7:00 pm CST

WARNING!
If you do not understand these directions, or if you have any doubts about the safety of the installation, please call a qualified technician. Check carefully to make sure there are no missing or defective parts. Improper installation may cause damage or serious injury. Do not use this product for any purpose that is not explicitly specified in this manual. Do not exceed weight capacity. We cannot be liable for damage or injury caused by improper mounting, incorrect assembly or inappropriate use.

TIPOVER WARNING

SERIOUS OR FATAL CRUSHING INJURIES CAN OCCUR FROM TIPOVER. TO HELP PREVENT TIPOVER: NEVER ALLOW CHILDREN TO CLIMB, STAND, HANG, OR PLAY ON ANY PART OF THE MONITOR OR STAND. USE TIPOVER RESTRAINT OR ANCHOR STAND TO WALL THE USE OF TIPOVER RESTRAINTS MAY ONLY REDUCE, BUT NOT ELIMINATE RISK OF TIPOVER.
WARNING: CHOKING HAZARD
SMALL PARTS – NOT FOR CHILDREN UNDER 3 YEARS. ADULT SUPERVISION IS REQUIRED.

PACKAGE CONTENTS

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(3\)

DO NOT EXCEED WEIGHT CAPACITY
Failure to do so may result in serious injury

ASSEMBLY STEPS

STEP 1 – Clamp Installation
Remove USB Cover (C1) from Base (C). Adjust the hand bolt completely down on the Lower Clamp (D).

  • 4”-1.90” (10-50mm) DESKTOPS 1.8”-3.1” (45-80mm) DESKTOPS
  • Install Upper Clamp (E) to Base (C) using
  • M6x8mm Screws (S-A) and 5mm Allen Wrench (T-A).
  • Install Upper Clamp (E) to Base (C) using
  • M6x8mm Screws (S-A) and 5mm Allen Wrench (T-A)VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG- \(6\)
  • Reinstall USB Cover (C1) onto Base (C) using
  • ST3x8mm Screws (S-D) and the Phillips end of 5mm Allen Wrench (T-A).VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG- \(7\)
  • Reinstall USB Cover (C1) onto Base (C) using 3x8mm Screws (S-D) and the Phillips end of 5mm Allen Wrench (T-A).

Attach the Lower Clamp (D) to the top two holes on the Upper Clamp (E) using M6x10mm Screws (S-B) and 4mm Allen Wrench (T-B).

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(8\)

Secure clamp assembly to the desktop. Attach Lower Clamp (D) to the bottom two holes on Upper Clamp (E) using M6x10mm Screws (S-B) and 4mm Allen Wrench (S-B). Secure clamp assembly to the desktop.

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(9\)

STEP 1 – Grommet
If the desktop does not have a preexisting grommet hole, use a ⅜” (10mm) drill bit to create one by drilling completely through the desktop.

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(10\)

Secure the plastic shroud to Base (C) using ST3x8mm Screws (S-D) and the Phillips end of 5mm Allen Wrench (T-A). Disassemble the Lower Clamp (D) using the Phillips end on a 5mm Allen Wrench (T-A) and separate the Hand Bolt (D1). Place Grommet Plate (F) on Hand Bold (D1) and secure Base (C)

desktop

Secure the plastic shroud to Base (C) using ST3x8mm Screws (S-D) and the Phillips end of 5mm Allen Wrench (T-A). Disassemble the Lower Clamp (D) using the Phillips end on 5mm Allen Wrench (T-A) and separate the Hand Bolt (D1). Place Grommet Plate (F) on Hand Bold (D1) and secure Base (C) to the desktop Place Lower Arm (A) onto Base (C), then place Upper Arm (B) onto Lower Arm (A). Tighten set screws using the flathead end on 4mm Allen Wrench (T-B).

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(10\)

STEP 3
Attach VESA Plate (G) to Upper Arm (B) using M8x30mm Screw (S-C) and 5mm Allen Wrench (T-A).

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(12\)

STEP 4
Install two Screws (M-A or M-B) and M5 Washers (M-C) using the Phillips end of a 5mm Allen Wrench (T-A) to the top VESA holes on the monitor leaving at least 3mm of clearance between the screw and monitor. Slide the monitor onto VESA Plate (G) making sure the screws sit within the slots.

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(12\)Install two Screws (M-A or M-B) and M5 Washers (M-C) using the Phillips end of 5mm Allen Wrench (T-A) to the top VESA holes on the monitor leaving at least 3mm of clearance between the screw and monitor. Slide the monitor onto VESA Plate (G) making sure the screws sit within the slots. Cable Management Remove plastic covers from Arms (A, B) using Phillips screwdriver end of 5mm Allen Wrench (T-A).

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(14\)Run cables from the monitor through the bottom of Arms (A, B), then reattach plastic covers.

Adjust as Desired

Remove plastic covers from Arms (A, B) using Phillips screwdriver end of 5mm Allen Wrench (T-A). Run cables from the monitor through the bottom of the Arms (A, B), then reattach plastic covers.
Use a 5mm Allen Wrench (T-A) to adjust the tilt.

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(17\)

Tension Adjustment
WARNING
The monitor must be installed on the mount before making tension adjustments to the gas spring arm.
While holding the arm in the horizontal position, adjust the gas spring tension using the 5mm Allen Wrench (T-A).

VIVO-STAND-V001OU-Pneumatic-Arm-Single-Monitor-Desk-Mount-With-USB-FIG-
\(18\)

CAUTION
To avoid damage to the monitor or mount, always ensure the arm is in a horizontal position before making adjustments. An additional person may be required to assist in some cases.

WARNING
The monitor must be installed on the mount before making tension adjustments to the gas spring arm.

Love your new VIVO setup and want to share?
Tag us in your photo! LAST UPDATED: 05/18/2023

REV3
Open Monday – Friday 7:00 am – 7:00 pm CST, our dedicated support team can offer immediate assistance with rapid response times. If any parts are received damaged or defective, please contact us. We are happy to replace parts to ensure you have a fully functioning product.

AVG. RESPONSE TIME (within office hrs): 1HR 8M

  • 23% within < 15m
  • 61% within < 1hr
  • 83% within < 2hr
  • 92% within < 3hr

FOR MORE VIVO PRODUCTS, CHECK OUT OUR WEBSITE AT: www.vivo-us.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Vivo User Manuals

Related Manuals