horizont LOGO APPLICATION NOTES
Fence tester
trapper
Fence Voltmeter 6 Light
Type 14494Chorizont 14494C Fence Tester Trapper 6
Light 87159C – 09/22

Application Notes

With this fence tester, the fence voltage at any point of the fence system or also the output voltage directly at the energiser can be measured.
The tester is operated without a battery.

Voltage measurement

For measurement, the device is switched between earth (earth stake) and fence (contact eye). Voltage values > 2.000 volts are to be rated as safe in accordance with VDE. The higher the voltage, the more secure your fence system works.

horizont 14494C Fence Tester Trapper 6 Light - FIGURE
1

Leads / voltage at the ground stake

In the case of leads, reverse currents generate a voltage at the ground pole. If there are voltages at the ground pole, discharges are present at the fence and must be removed. The grounding should be improved by adding ground piles.

horizont 14494C Fence Tester Trapper 6 Light - FIGURE
2

Faulty insulation

A defective insulation leads to current discharge over the iron pole. This can be determined with the help of the fence tester.

horizont 14494C Fence Tester Trapper 6 Light - FIGURE
3

Volt / Volts voltage
> 10.000 – 6.000 V very good
6.000 – 4.000 V good
4.000 – 2.000 V sufficient
Low kv too low

Subject to technical modifications!

EU Declaration of Conformity
Page 1
from 1
We
horizont group gmbh
Homberger Weg 4-6, D-34497 Korbach
declare under our sole responsibility that the products
Electric fencing units
Trademark : horizont
FENCE SCOUT II 14151/14151c
6-LEVEL TESTER 14494 / 14494c
WIRELESS TESTER 14495/ 14495c
DIGITAL VOLTMETER 14496 / 14496c
to which this deciaration relates, is in conformity with the following European Directives :
2001/98/EG/EC/CE – (General Product Safety Directive)
2014/30/EU/VE – (EMC Directive)
2011/66/EU/UVE – (Directive on the Restriction of Hazardous Substances in electonic equipment)
2012/19/EU/VE – (WEEE – Waste of Electrical and Electronic Equipment)
The products assessment concerning the “General product safety directive” is based on the following standards: EN 61326-1: 2013
The products assessment concerning Electromagnetic Compatibility (EMC Directive) is based on the following standards: EN 55011-1:2016
The products assessment concerning the “Waste of Electrical and Electronic Equipment” is based on the following standards: EN 50681:2012
Korbach, 16.04.2018
Place and date of issue:

Dieter Hake

horizont group gmbh
Animal Care
Homberger Weg 4-6
34497 Korbach
Germany
Telefon: +49 (0) 56 31 / 5 65 – 1 00
Telefax: +49 (0) 56 31 / 5 65 – 1 20
animalcare@horizont.com
www.horizont.com

Documents / Resources

| horizont 14494C Fence Tester Trapper 6 Light [pdf] Instruction Manual
14494C Fence Tester Trapper 6 Light, 14494C, Fence Tester Trapper 6 Light, Tester Trapper 6 Light, Trapper 6 Light, 6 Light, Light
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals