horizont trapper AN45 Electric Fencer Instruction Manual

June 12, 2024
Horizont

**horizont trapper AN45 Electric Fencer

**

Operating manual of the

trapper AN45 / trapper AN80 / trapper AN120

In association with the installation and safety instructions for the SECURA ANIMAL or SECURA SECURITY electric fencers (www.horizont.com/securaanimal or www.horizont.com/securasecurity)

General Safety Instructions

Switch off the pasture fencer before coming into contact with it!

Operating manual information
The operating manual has some important instructions on handling the energizer. All technical details in the manual have been prepared and compiled with the greatest possible care. Even so, errors cannot be excluded. We wish to point out that we cannot assume any guarantee, legal responsibility or any liability for consequences attributable to possible lack of details. We would, at all times, welcome any notification of possible errors.
Safe working depends on the indicated safety and handling instructions being adhered to. Also to be adhered to are those local accident prevention provisions which are in force where the energizer is used as well as the general safety requirements.
The operating manual is to be studied carefully before any work begins!
As an integral part of the overall product it is to be securely kept right next to the energizer and for ease of consultation by the personnel.
Do hand over this manual should this product be sold or passed on to another party. For a better understanding of what is involved, some of the diagrams in this manual may not be true-to-scale and may deviate slightly from the actual constructional design.

Description and Construction of the Product

The energizer transmits voltage pulses to a connected pasture fence.

Caution! Only the optional additional parts prescribed by the manufacturer are to be used.

Installation

Installation:
The energizer can either be mounted on a wall or on a stable post. The earthing rod (longitudinal rod) must be driven as deeply as possible into the ground at a moist location and connected by a corrosion-resistant wire to the earthing terminal of the energizer.

Connect the fence cable to the terminal with the lightning symbols .
The energizer is only protected against moisture if it is properly installed.
Shield the energizer from direct solar irradiation. Do not operate the ener- gizer when it lies on the ground. Set the energizer up in a location where there is no fire hazard.

Earthing:
Good earthing of the fence is extremely important for trouble-free operation and optimum performance of the energizer; therefore it should be earthed at a preferably moist and overgrown location.
If the ground is dry and the fence is long, an additional earth conductor with intermediate earths (every 50 m) should be installed along the fence.

Installation with a 12V rechargeable battery:
Connect the 12V rechargeable battery (red + / black -), ensure clean pole terminals and correct polarity. The device will not start if the polarity is reversed.

CAUTION!
Only use rechargeable 12 V batteries; only charge rechargeable batteries with ventilation in well-ventilated rooms. Disconnect the rechargeable battery from the energizer during the charging process. The rechargeable battery should be recharged before and after every use as well as during longer periods of storage (every 2 months) and disconnected from the energizer.

The energizer has an AUTO-ON function which ensures that as soon as power is connected the energizer starts to operate.
Remaining capacity

The rechargeable battery must be recharged at the latest when discharged down to 80% (only 20% remaining left) to prevent a flat battery. The rechargeable battery indicator lights up.

Do note that temperature and measurement deviation may cause these figures to vary.können.

Installation with a 230V/110V mains adapter:
For the operation of 230V power supply only use the mains adapter 47PSU0008EU/UK, as specified on the intermediate plate in the device!
Connect the mains adapter with the energizer, as described in Fig. 4, via the mains connection (2) .

Installation with 230V/110V:
Insert the energizer’s mains plug into the power socket.
CAUTION!
The energizer has an AUTO-ON function. As such, the energizer starts following connection to the mains network.

Commissioning

Commissioning – Power supply units:
Device starts automatically once it is connected to the power supply After 1 second, you will hear a rhythmic even ticking of the pulses; the device is in operation.
The energizer transmits pulses to the fence and the LED display lights up.
The fact of the status LEDs not lighting up points to a defect in the power supply

Disassembly, Dismantling, Storage and Transport

Disassembly, Dismantling
Before starting disassembly:

  • Switch off energizer
  • Disconnect entire energy supply from the energizer.
  • Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally compatible manner.

Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety & environmental protection provisions in force.

Storage, Transport
Ensure that the energizer is both stored and transported only when switched off.

NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
Do note that temperature and measurement deviation may cause these figures to vary.

Faults and Repairs

WARNING!
Repairs may only be carried out by qualified persons.
Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations!

Spare parts

Spare parts

Pos-Nr.| trapper AN45 (10867)| trapper AN80 (10866)| trapper AN120 (10865)
---|---|---|---
1| 84040A| 84040A| 84040A
2| 88128| 88128| 88128
3| 6068521| 6068521| 6068521
4| 88128RT| 88128RT| 88128RT
5| 60704| 60705| 60719
6| 607091| 607091| 607091
7| 84041| 84041| 84041
8| 94581| 94581| 94581

Installation and connection

Installation and connection
Installation and connection

For 230V operation the energizer should be and the adapter must be installed in a room protected from moisture.

Technical data

Fig. 5
Technical data

| Joule IN| Joule OUT| max.Spannung| Stromverbrauch| Spannung 500 Ω
---|---|---|---|---|---
trapper AN45

(10867)

| ****

0,8 J

| ****

0,45 J

| ****

~ 7.900 V

| ****

50 mA

| ****

~ 3.300 V

trapper AN80

(10866)

| ****

1,2 J

| ****

0,8 J

| ****

~ 8.400 V

| ****

90 mA

| ****

~ 3.600 V

trapper AN120

(10865)

| ****

2,4 J

| ****

1,2 J

| ****

~ 8.600 V

| ****

145 mA

| ****

~ 4.000 V

Subject to technical alterations!

max. fence line length

Fig. 6
CEE:
max. fence line length

trapper AN120
Type 10865
attestation
APAVE 7961108-001-1/C
trapper AN80
Type 10866
attestation
APAVE 7961108-001-1/B
trapper AN45
Type 10867
attestation
APAVE 7961108-001-1/A

Total Weight

Total Weight

EU Declaration of conformity

EU Declaration of conformity

Instruction manual

Instruction manual

Website
Discover our website and find more products, highlights, campaigns, movies, tips and more.
We look forward to your visit!
www.horizont.com

Advisor electric fencing
By means of our electric fence advisor you can receive useful information about how to arrange a reliable electric fence system.
www.horizont.com/ACratgeberWeidezaun

Electric fencing catalogue
horizont offers a comprehensive range of electric fencing material. Please don´t hesitate to ask for a catalogue or have a look at our website to download it.
www.horizont.com/ACkataloge

CUSTOMER SUPPORT

horizont group gmbh
Animal Care
Homberger Weg 4-6
34497 KORBACH GERMANY
+49 (0) 56 31 / 5 65 – 1 00
+49 (0) 56 31 / 5 65 – 1 20
agrar@horizont.com
horizont.com

All data is made subject to sentences mistakes and literal mistakes, subject to product changes and falsity.
Reprint, even in extracts and use of the pictures only with written permission by horizont group gmbh.

horizont logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals