horizont AN45 12 V 230 V Electric Fence Trapper Animal Care Instruction Manual
- June 13, 2024
- Horizont
Table of Contents
- General Safety Instructions
- Description and Construction of the Product
- Installation
- Commissioning
- Disassembly, Dismantling, Storage and Transport
- Faults and Repairs
- Spare parts
- Montage und Anschluss
- Technical data
- EU Declaration of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Instruction manual
Electric Fencer
trapper AN45
Type 10867
trapper AN80
Type 10866
trapper AN120
Type 10865
Operating manual of the
trapper AN45 / trapper AN80 / trapper AN120
**** In association with the installation and safety instructions for the
SECURA ANIMAL or SECURA SECURITY electric fencers (www.horizont.com/securaanimal or www.horizont.com/securasecurity)
General Safety Instructions
Switch off the pasture fencer before coming into contact with it!
Operating manual information
The operating manual has some important instructions on handling the
energizer. All technical details in the manual have been prepared and compiled
with the greatest possible care. Even so, errors cannot be excluded. We wish
to point out that we cannot assume any guarantee, legal responsibility or any
liability for consequences attributable to possible lack of details. We would,
at all times, welcome any notification of possible errors. Safe working
depends on the indicated safety and handling instructions being adhered to.
Also to be adhered to are those local accident prevention provisions which are
in force where the energizer is used as well as the general safety
requirements.
The operating manual is to be studied carefully before any work begins!
As an integral part of the overall product it is to be securely kept right
next to the energizer and for ease of consultation by the personnel.
Do hand over this manual should this product be sold or passed on to another
party. For a better understanding of what is involved, some of the diagrams in
this manual may not be true-to-scale and may deviate slightly from the actual
constructional design.
Description and Construction of the Product
The energizer transmits voltage pulses to a connected pasture fence.
Caution! Only the optional additional parts prescribed by the manufacturer are to be used.
Installation
Installation:
The energizer can either be mounted on a wall or on a stable post. The
earthing rod (longitudinal rod) must be driven as deeply as possible into the
ground at a moist location and connected by a corrosion-resistant wire to the
earthing terminal ( ) of the energizer.
Connect the fence cable to the terminal with the lightning symbols ( ) .
The energizer is only protected against moisture if it is properly installed.
Shield the energizer from direct solar irradiation. Do not operate the
energizer when it lies on the ground. Set the energizer up in a location where
there is no fire hazard.
Earthing:
Good earthing of the fence is extremely important for trouble-free operation
and optimum performance of the energizer; therefore it should be earthed at a
preferably moist and overgrown location.
If the ground is dry and the fence is long, an additional earth conductor with
intermediate earths (every 50 m) should be installed along the fence.
IInstallation with a 12V rechargeable battery:
Connect the 12V rechargeable battery (red + / black -), ensure clean pole
terminals and correct polarity. The device will not start if the polarity is
reversed.
CAUTION!
Only use rechargeable 12 V batteries; only charge rechargeable batteries with
ventilation in well-ventilated rooms Disconnect the rechargeable battery from
the energizer during the charging process. The rechargeable battery should be
recharged before and after every use as well as during longer periods of
storage (every 2 months) and disconnected from the energizer. The energizer
has an AUTO-ON function which ensures that as soon as power is connected the
energizer starts to operate.
Installation with a 230V/110V mains adapter:
**For the operation of 230V power supply only use the mains adapter
47PSU0008EU/UK, as specified on the intermediate plate in the device! Connect
the mains adapter with the energizer, as described in Fig. 4, via the mains
connection12.
Installation with 230V/110V:
Insert the energizer’s mains plug into the power socket.
CAUTION!** The energizer has an AUTO-ON function. As such, the energizer
starts following connection to the mains network.
Commissioning
Commissioning – Power supply units:
Device starts automatically once it is connected to the power supply After 1
second, you will hear a rhythmic even ticking of the pulses; the device is in
operation.
The energizer transmits pulses to the fence and the LED display lights up.
The fact of the status LEDs not lighting up points to a defect in the power
supply
Disassembly, Dismantling, Storage and Transport
Disassembly, Dismantling Before starting disassembly:
- Switch off energizer
- Disconnect entire energy supply from the energizer.
- Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compatible manner.
Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety & environmental protection provisions in force.
Storage, Transport
Ensure that the energizer is both stored and transported only when switched
off.
NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
Faults and Repairs
WARNING!
Repairs may only be carried out by qualified persons.
Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations!
Spare parts
Pos-Nr.| trapper AN45 (10867)| trapper AN80 (10866)| trapper
AN120 (10865)
---|---|---|---
1| 84040A| 84040A| 84040A
2| 88128| 88128| 88128
3| 6068521| 6068521| 6068521
4| 88128RT| 88128RT| 88128RT
5| 60704| 60705| 60719
6| 607091| 607091| 607091
7| 84041| 84041| 84041
8| 94581| 94581| 94581
Montage und Anschluss
For 230V operation the energizer should be and the adapter must be installed in a room protected from moisture.
Technical data
| Joule IN| Joule OUT| max.Spannung| Stromverbrauch|
Spannung500 Ω
---|---|---|---|---|---
trapper AN45 (10867)| 0,8 J| 0,45 J| – 7.900 V| 50 mA| – 3.300 V
trapper AN80 (10866)| 1,2 J| 0,8 J| – 8.400 V| 90 mA| – 3.600 V
trapper AN120 (10865)| 2,4 J| 1,2 J| – 8.600 V| 145 mA| – 4.000 V
Subject to technical alterations!
CEE:
max. fence line length
trapper AN120
Type 10865
attestation
APAVE 7961108-001-1/C
trapper AN80
Type 10866
attestation
APAVE 7961108-001-1/B
trapper AN45
Type 10867
attestation
APAVE 7961108-001-1/A
0,74 kg
Total Weight
EU Declaration of Conformity
Seite: 1
von: 1
Wir horizont group gmbh
Homberger Weg 4-6, D-34497 Korbach
declare under our sole responsibility that the products/
. Electric fencing units
Trademark
turbomax B27
ranges B29
ranger BES:
(rapper B12
trapper B22
(rapper ABI2
turbomax 41430
ranger M270
ranges N420
holshock NSOO
farmer N100
farmer N200
‘wapper N15
‘wapper N45| Type 10285
Type 10565
Type 10841
Type 10616
Type 10620
Type 14497
Type 10748
Type 10808
Type 10742
Type 10814
Type 10632
Type 10996
Type 104271
Type 10864| turhomax ANBCO
ranger ANSED
ranger AN@9D
ranger AN4SOHIMPS.
tanger AN2000
ranger AN3000
ranger AN4800
tanger AN4BD0HIMPS
holshock A90
hotshock A300
farmer ANTOO
farmer AN200
farmer AN3OO
farmer AN1000
farmer AN100Qsolar| Type 10749
Type 10997
Type 10857
Type 10857HIMPS
Type 10854
Type 10992
Type 10093
Type 10993HIMPS
Type 10638
Type 10613
Type 10896
Type 10897
Type 10882
Type 10865
‘Type 10856| (rapper AN4S
(rapper ANSO
trapper AN120
hotehock ABN37
tasmer ABN30
farmer ASSO
trapper AS25
trapper ASSO| Type 10867
Type 10866
Type 10865
Type 10892
Type 10691
Type 14485
Type 14982
Type 14983
---|---|---|---|---|---
to which this declaration relates, is in conformity with the following
European Directives : ;
2001/95/EG/EC/CE = (General Product Safety Directive)
2014/30/EU/VE (EMC Directive) (directive CEM)
2011/65/EU/VE (Directive on the Restriction of Hazardous Substances in
electonic equipment)
2012/19/EU/UE (WEEE – Waste of Electrical: and Electronic Equipment)
The products assessment concerning the “General product safety directive” Is
based on the following standards:
EN 60695-1:2012 + AC:2014
EN 60336-2-76:2005 + A1:2006 + A11:2008 + A12:2010 + A2:2015
The products assessment concerning Electromagnetic Compatibility (EMC
Directive) is based on the following standards:
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:2015
The products assessment concerning the “Waste of Electrical and Electronic
Equipment* is based on the following standards
Korbach, 04.11.2019
Ort and Datum der Ausstellung:
Place and date of issue:
Lieu et date de (‘exposition:
Website
Discover our website and find more products, highlights, campaigns, movies,
tips and more.
We look forward to your visit!
www.horizont.com
Advisor electric fencing
Ratgeber „Weidezaun“ |
By means of our electric fence advisor you can receive useful information
about how to arrange a reliable electric fence system.
www.horizont.com/ACratgeberWeidezaun
Electric fencing catalogue
Weidezaun-Katalog |
horizont offers a comprehensive range of electric fencing material. Please
don´t hesitate to ask for a catalogue or have a look at our website to
download it.
www.horizont.com/ACkataloge
All data is made subject to sentences mistakes and literal mistakes, subject
to product changes and falsity.
Reprint, even in extracts and use of the pictures only with written permission
by horizont group gmbh.
horizont group gmbh
Animal Care
Homberger Weg 4-6
34497 KORBACH GERMANY
+49 (0) 56 31 / 5 65 – 1 00
+49 (0) 56 31 / 5 65 – 1 20
agrar@horizont.com
horizont.com
References
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com