horizont N500 hotshock Electric Fence Instruction Manual
- June 13, 2024
- Horizont
Table of Contents
- horizont N500 hotshock Electric Fence
- Product Information
- Product Usage Instructions
- General Safety Instructions
- Description and Construction of the Product
- Installation
- Commissioning
- Disassembly, Dismantling, Storage and Transport
- Faults and Repairs
- Spare parts
- Installation and connection
- Technical data
- Total Weight
- Documents / Resources
horizont N500 hotshock Electric Fence
Product Information
The hotshock N500 (Type 10614) is an energizer designed for transmitting voltage pulses to a connected pasture fence. It is used in conjunction with the SECURA ANIMAL or SECURA SECURITY electric fencers. The energizer comes with general safety instructions and is protected against moisture when properly installed. It has an AUTO-ON function and features a CONTROL LED (LED1) that lights up green when working trouble-free.
Product Usage Instructions
- Switching Off: Before coming into contact with the energizer, always switch it off.
- Installation:
- Mount the energizer on a wall or stable post.
- Drive the earthing rod (longitudinal rod) as deeply as possible into a moist location.
- Connect the earthing rod to the earthing terminal ( ) of the energizer using a corrosion-resistant wire.
- Connect the fence cable to the terminal with the lightning symbols ( or ).
- Ensure proper installation for protection against moisture.
- Earthing: Proper earthing of the fence is crucial for trouble-free operation. Ideally, earth the fence at a moist and overgrown location. If the ground is dry and the fence is long, install additional earth conductors with intermediate earths (every 50 m) along the fence.
- Commissioning:
- Connect the energizer to the power supply.
- The device will start automatically and emit rhythmic ticking pulses after 1 second.
- The LED display will light up to indicate the device is in operation.
- If the status LEDs do not light up, there may be a defect in the power supply.
- Disassembly, Dismantling, Storage, and Transport:
- Before disassembly, switch off the energizer and disconnect the entire energy supply.
- Dispose of operating/auxiliary materials and clean sub-assemblies and parts according to local industrial safety & environmental protection provisions.
- Store and transport the energizer only when switched off.
- Rechargeable batteries should be stored in ventilated and dry rooms.
- Faults and Repairs: Repairs should only be carried out by qualified persons using spare parts prescribed by the manufacturer.
Please note that the information provided is subject to technical alterations. For more detailed instructions and information, refer to the original instruction manual of the hotshock N500.
Operating manual of the hotshock N500
In association with the installation and safety instructions for the SECURA
ANIMAL or SECURA SECURITY electric fencers
(www.horizont.com/securaanimal or
www.horizont.com/securasecurity)
General Safety Instructions
Switch off the pasture fencer before coming into contact with it!
Operating manual information
- The operating manual has some important instructions on handling the energizer. All technical details in the manual have been prepared and compiled with the greatest possible care. Even so, errors cannot be excluded. We wish to point out that we cannot assume any guarantee, legal responsibility or any liability for consequences attributable to possible lack of details. We would, at all times, welcome any notification of possible errors. Safe working depends on the indicated safety and handling instructions being adhered to. Also to be adhered to are those local accident prevention provisions which are in force where the energizer is used as well as the general safety requirements.
- The operating manual is to be studied carefully before any work begins!
- As an integral part of the overall product it is to be securely kept right next to the energizer and for ease of consultation by the personnel.
- Do hand over this manual should this product be sold or passed on to another party. For a better understanding of what is involved, some of the diagrams in this manual may not be true-to-scale and may deviate slightly from the actual construction-al design.
Description and Construction of the Product
The energizer transmits voltage pulses to a connected pasture fence.
Caution! Only the optional additional parts prescribed by the
manufacturer are to be used.
Installation
- The energizer can either be mounted on a wall or on a stable post. The earthing rod (longitudinal rod) must be driven as deeply as possible into the ground at a moist location and connected by a corrosion-resistant wire to the earthing terminal ( ) of the energizer.
- Connect the fence cable to the terminal with the lightning symbols
- The energizer is only protected against moisture if it is properly installed.
- Shield the energizer from direct solar irradiation. Do not operate the energiz-er when it lies on the ground. Set the energizer up in a location where there is no fire hazard.
- The energizer has two fence outputs: = maximum; = reduced. Both outputs can simultaneously operate separate fences.
- A short-circuit at the reduced fence output will hardly affect the maximum out-put, but a defect at the maximum output will additionally lower the reduced output.
- Only the reduced fence output is shown on the display (LED 4-9) given the connection of two fences.
Earthing:
- Good earthing of the fence is extremely important for trouble-free operation and optimum performance of the energizer; therefore it should be earthed at a preferably moist and overgrown location.
- If the ground is dry and the fence is long, an additional earth conductor with intermediate earths (every 50 m) should be installed along the fence.
Installation with 230V/110V:
- Insert the energizer’s mains plug into the power socket.
CAUTION!
- The energizer has an AUTO-ON function. As such, the energizer starts following connection to the mains network.
Commissioning
- Commissioning – Power supply units:
- Device starts automatically once it is connected to the power supply After 1 second, you will hear a rhythmic even ticking of the pulses; the device is in operation.
- The energizer transmits pulses to the fence and the LED display lights up. The fact of the status LEDs not lighting up points to a defect in the power supply
Disassembly, Dismantling, Storage and Transport
- Disassembly, Dismantling
- Before starting disassembly:
- Switch off energizer
- Disconnect entire energy supply from the energizer.
- Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compati-ble manner.
- Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety & environmental protection provisions in force.
Storage, Transport
- Ensure that the energizer is both stored and transported only when switched off.
NOTE!
- Ensure that rechargeable batteries are stored in ventilated and dry rooms.
Faults and Repairs
WARNING!
- Repairs may only be carried out by qualified persons.
- Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations Cycle sequence monitoring
- The energizer has a cycle sequence monitoring unit to stop any undue energy being supplied to the fence, cycle pulses fail-ing and to ensure that herding security is maintained. The effect of the cycle sequence rate falling to under 1 second or for no pulses to occur for more than 5 seconds is for LED3 to flash in red. This could be due to lightning strikes, continuous flash-overs at the fence and a defective energizer. The cycle sequence monitoring unit operates to attain a preferably high degree of security – and fully independently of pulse generation. For this reason the display may be incorrect under certain operating modes. Send the energizer in for repair if the cycle sequence monitoring indicates a fault either following an energizer restart or in the “Normal“ operating mode.
- The CONTROL LED (LED1) lights up green when the energizer is working trouble-free.
Table 14
Faults | Display | Corrective action |
---|---|---|
Herding voltage too low | Not all LEDs of the fence voltage indicator light up | |
green | Set the Normal mode |
Spare parts
Pos- Nr. | hotshock N500 |
---|---|
1 | 97683 |
2 | 91015 |
3 | 97929 |
4 | 98445 |
5 | 60159T |
6 | 89779 |
7 | 60523 |
8 | 88148 |
9 | 97690 |
10 | 84719 |
11 | 84741 |
12 | 83403 |
13 | 89976 |
14 | 94581 |
15 | 89474 |
16 | 89224 |
17 | 60224 |
18 | 83770 |
19 | 97999 |
20 | 98271 |
CEE: max. fence line length
Subject to technical alterations
Installation and connection
Technical data
Total Weight
Website
- Discover our website and find more products, highlights, campaigns, movies, tips and more.
- We look forward to your visit!
- Entdecken Sie unsere Website und finden Sie weitere
- Artikel, Highlights, Aktionen, Filme, Tipps uvm.
- Wir freuen uns auf Sie
Advisor electric fencing
- By means of our electric fence advisor you can receive useful information about how to arrange a reliable electric fence system.
Electric fencing catalogue
- horizont offers a comprehensive range of electric fencing material. Please don´t hesitate to ask for a catalogue or have a look at our website to download it.
- www.horizont.com/ACkataloge
- All data is made subject to sentences mistakes and literal mistakes, subject to product changes and falsity.
- Reprint, even in extracts and use of the pictures only with written permission by horizont group gmbh.
- horizont group gmbh
- Animal Care
- Homberger Weg 4-6
- 34497 KORBACH GERMANY
- +49 (0) 56 31 / 5 65 – 1 00
- +49 (0) 56 31 / 5 65 – 1 20
- agrar@horizont.com
- horizont.com
Documents / Resources
|
horizont N500 hotshock Electric
Fence
[pdf] Instruction Manual
N500 hotshock Electric Fence, N500, hotshock Electric Fence, Electric Fence,
Fence
---|---
References
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com
- Willkommen bei der horizont Gruppe | horizont.com