MEAN WELL HRPG-1000N3 Ultra High Peak Power Supply Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
MEAN WELL HRPG-1000N3 Ultra High Peak Power Supply
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 94%
- Withstand 300VAC surge input for 5 seconds
- Up to 320% peak power capability
- Protections: Short circuit / Overload / Over voltage /
Over temperature
- Built-in cooling fan ON-OFF control
- Current sharing up to 4000W (3+1)
- Built-in DC OK signal
- Built-in remote ON-OFF control
- Standby 5V@0.3A
- Built-in remote sense function
- No load power consumption<0.85W (Note.6)
- 5 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Aging equipment
- RF application
- For inductive and capacitive load
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
HRPG-1000N3 series is a 1000W single output AC/DC with ultra-hight peak power supply. This series operates for 90~264 VAC input voltage and offers models with different rated voltage ranging between 12 and 48 V that can satisfy the demands for all kinds of industrial equipments. Each model is cooled by the built-in fan with speed control, working for the temperature up to 70°C. Moreover, HRPG-1000N3 has various built-in functions such as auxiliary power, remote sense and remote on -off control, offering vast design flexibility for industrial application.It can provide 320% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Model Encoding / Order Information
SPECIFICATION
MODEL|  HRPG-1000N3-12|  HRPG-1000N3-24|  HRPG-1000N3-36|
HRPG-1000N3-48
---|---|---|---|---  
OUTPUT
|  DC VOLTAGE|  12V| 24V| 36V| 48V
RATED CURRENT|  80A| 42A| 28A| 21A
CURRENT RANGE|  0 ~ 80A| 0 ~ 42A| 0 ~ 28A| 0 ~ 21A
RATED POWER|  960W| 1008W| 1008W| 1008W
RIPPLE & NOISE (max.) **Note.2|  150mVp-p| 200mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE|  11 ~ 14V| 22 ~ 28V| 32 ~ 38V| 46 ~ 56V
VOLTAGE TOLERANCE Note.3|  ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION|  ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION|  ±2.0%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME|  1000ms, 50ms/230VAC             2000ms, 50ms/115VAC at
full load
HOLD UP TIME (Typ.)**|  16ms/230VAC             16ms/115VAC at full load  
INPUT
|  VOLTAGE RANGE|  90 ~ 264VAC(300VAC for 5 sec.)             127 ~ 370VDC
FREQUENCY RANGE|  47 ~ 63Hz
POWER FACTOR (Typ.)|  PF>0.95/230VAC              PF>0.99/115VAC at full
load
EFFICIENCY (Typ.)|  91.5%| 93%| 93%| 94%
AC CURRENT (Typ.)|  8.5A/115VAC          5A/230VAC
INRUSH CURRENT (Typ.)|  25A/115VAC             40A/230VAC
LEAKAGE CURRENT|  <1.2mA / 240VAC  
PROTECTION
| ****
OVERLOAD **Note.4**
|  Output power >105% rated for more than 5 seconds then shut down o/p
voltage, re-power on to recover
Output power >350% rated then shut down o/p voltage, re-power on to recover  
OVER VOLTAGE
|  14.5 ~ 16.5V| 29 ~ 33V| 39 ~ 46V| 58 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE|  Shut down o/p voltage, recovers automatically after
temperature goes down  
FUNCTION
|  CURRENT SHARING|  Up to 4000W or (3+1) units. Please refer to the
function manual.
REMOTE ON-OFF CONTROL|  Power ON : short; Power OFF : open. Please refer
to the function manual.
REMOTE SENSE|  Compensate voltage drop on the load wiring up to 0.5V.
Please refer to the function manual.
DC-OK SIGNAL|  The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn
off = 0 ~ 1V. Please refer to the function manual.
5V STANDBY|  5VSB : 5V@0.3A ; tolerance±5%, ripple :
50mVp-p(max.)
FAN CONTROL|  Fan on/off by NTC(RT50) or 30% load min.  
ENVIRONMENT
|  WORKING TEMP.|  -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY|  20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY|  -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT|  ±0.03%/℃ (0 ~ 50℃)
VIBRATION|  10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes  
SAFETY & EMC
|  SAFETY STANDARDS|  UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS
EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE|  I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE|  I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH  
EMC EMISSION
|  Parameter|  Standard|  Test Level / Note
Conducted| BS EN/EN55032 (CISPR32)| Class B
Radiated| BS EN/EN55032 (CISPR32)| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–  
EMC IMMUNITY
|  BS EN/EN55035, BS EN/EN61000-6-2
Parameter|  Standard|  Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| Level 4, 2KV/Line-Line 4KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
|  MTBF|  989.2K hrs min.        Telcordia SR-332 (Bellcore) ;
130.6K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION|  21810561.5mm  (LWH)
PACKING|  1.46Kg;8pcs/12.8Kg/1.58CUFT  
NOTE
- 
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 C of ambient temperature. 
- 
Ripple & noise are measured at 20MHz of bandwidth by using a 12* twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor. 
- 
Tolerance: includes set up tolerance, line regulation and load regulation. 
- 
After protection, restart the device at an interval of about 30 seconds. 
- 
Derating may be needed under low input voltages. Please check the derating curve for more details. 
- 
Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to an increase of the set-up time. 
- 
No load power consumption 0.85W when RC+ & RC- (CN100 pin3,4) open. 
- 
The power supply is considered a component that will be installed into a final equipment. All the MC tests are been executed by mounting the unit on a 360mm *700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it stil meets MC directives. For guidance on how to 
 perform these MC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
- 
The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft) - roduct Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
 
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Function Manual
- Peak Power  
For example (24V model) :
Function Description of CN100
| Pin No. | Function | Description | 
|---|---|---|
| 1 | AUXG | Auxiliary voltage output ground. | 
| 2 | AUX | Auxiliary voltage output, 4.75~5.25V, referenced to pin 1(AUXG). The | 
maximum load current is 0.3A. This output is not controlled by the “remote
ON/OFF control”.
3| RC+| Turns the output on and off by electrical or dry contact between pin 4
(RC-), Short: Power ON, Open: Power OFF.
4| RC-| Remote control ground.
5| CS| Current sharing signal. When units are connected in parallel, the CS
pins of the units should be connected to allow current balance between units.
6,8| GND| This pin connects to the negative terminal(-V). Return for DC-OK
signal output.
7| DC-OK| DC-OK signal is a TTL level signal, referenced to pin8(DC-OK GND).
High when PSU turns on.
9| +S| Positive sensing. The +S signal should be connected to the positive
terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
10| -S| Negative sensing. The -S signal should be connected to the negative
terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.  
Function Manual
- 
Remote Sense 
 The remote sensing compensates voltage drop on the load wiring up to 0.5V.
- 
DC-OK Signal 
 DC-OK signal is a TTL level signal. High when PSU turns on.Between DC-OK(pin7) and GND(pin6,8)| Output Status
 ---|---
 3.3 ~ 5.6V| ON
 0 ~ 1V| OFF
- 
Remote ON-OFF Control 
 The PSU can be turned ON/OFF by using the
 “Remote Control” function.Between RC+(pin3) and RC-(pin4)| Output Status
 ---|---
 SW ON (Short)| ON
 SW OFF (Open)| OFF
- 
Current Sharing 
 HRPG-1000N3 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited belo- The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
- Difference of output voltages among parallel units should be less than 0.2V.
- The total output current must not exceed the value determined by the following equation:
- Maximum output current at parallel operation= (Rated current per unit) (Number of unit) X0.9
- When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit) (Number of unit) the current shared among units may not be fully balanced. 
 
Mechanical Specification

AC Input Terminal Pin No.
Assignment
| Pin No. | Assignment | 
|---|---|
| 1 | AC/L | 
| 2 | AC/N | 
| 3 | FG | 
DC Output Terminal Pin No.
Assignment
| Pin No. | Assignment | 
|---|---|
| 1~3 | +V | 
| 4~6 | -V | 
Connector Pin No. Assignment(CN100) : HRS DF11-10DP-2DS or equivalent
| Pin No. | Assignment | Pin No. | Assignment | Mating Housing | Terminal | 
|---|---|---|---|---|---|
| 1 | AUXG | 6,8 | GND | 
HRS DF11-10DS
or equivalent
|
HRS DF11-**SC
or equivalent
2| AUX| 7| DC-OK
3| RC+| 9| +S
4| RC-| 10| -S
5| CS| |  
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>