Danger!
When using the equipment, a few safety precautions must be observed to avoid injuries and damage. Please read the complete operating instructions and safety regulations with due care. Keep this manual in a safe place, so that the information is available at all times. If you give the equipment to any other person, hand over these operating instructions and safety regulations as well. We cannot accept any liability for damage or accidents which arise due to a failure to follow these instructions and the safety instructions.

Explanation of the symbols used (see Fig. 3)

  1. Danger! – Read the operating instructions to reduce the risk of injury.
  2. Caution! Wear ear-muff s. The impact of noise can cause damage to hearing.
  3. Beware of electrical voltage!
  4. Beware of hot parts!
  5. Warning! The unit will start up automatically without warning if the pressure drops below cut-in pressure!
  6. PS: Max. operating pressure
    Tax : Max. operating temperature
    Tin : Min. operating temperature
    V: Tank capacity

Safety regulations

The corresponding safety information can be found in the enclosed booklet. Danger! Read all safety regulations and instructions. Any errors made in following the safety regulations and instructions may result in an electric shock, fi re and/or serious injury. Keep all safety regulations and instructions in a safe place for future use.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they  have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

Layout and items supplied

2.1 Layout (Fig. 1-3)

  1. Housing cover
  2. Pressure tank
  3. Hook for cable store
  4. Foot
  5. Quick-lock coupling (regulated compressed air)
  6. Pressure gauge (for reading the set pressure)
  7. Pressure regulator
  8. ON/OFF switch
  9. Transport handle
  10. Safety valve
  11. Drainage screw for condensation water
  12. Storage compartment for 8-piece adapter set
  13. Storage hook for tire pressure gauge

2.2 Items supplied
Please check that the article is complete as specifi ed in the scope of delivery. If parts are missing, please contact our service center or the sales outlet where you made your purchase at the latest within 5 working days after purchasing the product and upon presentation of a valid bill of purchase. Also, refer to the warranty table in the service information at the end of the operating instructions.

  • Open the packaging and take out the equipment with care.
  • Remove the packaging material and any packaging and/or transportation braces (if available).
  • Check to see if all items are supplied.
  • Inspect the equipment and accessories for transport damage.
  • If possible, please keep the packaging until the end of the guarantee period.

Danger!
The equipment and packaging material are not toys. Do not let children play with plastic bags, foils or small parts. There is a danger of swallowing or suffocating!

  • Original operating instructions
  • Safety information

Proper use

The compressor is designed for generating compressed air for tools operated by compressed air.
The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.
Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes.

Technical data

Mains connection: ………………220-240 V ~ 50 Hz
Motor rating kW: …………………………………….. 1.2
Compressor speed min-1: ……………………… 3800
Operating pressure bar: …………………………….. 8
Pressure vessel capacity (in liters): ……………… 6
Theoretical suction rate l/min.: ………………… 190
Output (compressed air) at 7 bar: …. 55 liters/min
Output (compressed air) at 4 bar: …. 77 liters/min
Sound power level Lain dB: ……………………… 97
Uncertainty KWA………………………………… 0.65 dB
Sound pressure level Plaint dB: …………………. 77
Uncertainty KpA…………………………………. 0.65 dB
Protection type: ……………………………………. IP20
Weight of the unit in kg: ………………….approx. 8.8

Danger!
Noise
The noise emission values were measured in accordance with EN ISO 3744.

Before starting the equipment

Warning!
Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.

  • Examine the machine for signs of transit damage. Report any damage immediately to the company which delivered the compressor.
  • The compressor should be set up near the working consumer.
  • Avoid long air lines and long supply lines (extensions).
  • Make sure the intake air is dry and dust-free.
  • Do not set up the compressor in damp or wet rooms.
  • The compressor may only be used in suitable rooms (with good ventilation and an ambient temperature from +5°C to +40°C). There must be no dust, acids, vapors,  explosive gases or inflammable gases in the room.
  • The compressor is designed to be used in dry rooms. It is prohibited to use the compressor in areas where work is conducted with sprayed water.
  • The equipment must be set up where it can stand securely.
  • Use flexible hoses in order to prevent transmitting unacceptable loads to the pipeline system at the connection between the compressor system and the pipeline system.
  • It is essential to use separators, traps and drains which process the liquids produced by the compressor before the compressor system is put into operation.
  • Supply hoses at pressures above 7 bar should be equipped with a safety cable (e.g. a wire rope).

Assembly and starting

Important!
You must fully assemble the equipment before using it for the fi rest time.

6.1 Mains connection

  • Long supply cables, extensions, cable reels etc. cause a drop in voltage and can impede motor start-up.
  • At low temperatures below +5°C, sluggishness may make starting difficult or impossible.

6.2 ON/OFF switch (Fig. 1)
To switch on the equipment, set the On/Off switch (8) to position 1.
To switch off the equipment, move the On/Off switch (8) to position 0 .

6.3 Setting the pressure (Fig. 1)

  • You can adjust the pressure on the pressure gauge (6) using the pressure regulator (7).
  •  The set pressure can be drawn from the quick-lock coupling (5).

6.4 Setting the pressure switch
The pressure switch is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar

Replacing the power cable

Danger!
If the power cable for this equipment is damaged, it must be replaced by the manufacturer or its after-sales service or similarly trained personnel to avoid danger.

Cleaning, maintenance and ordering of spare parts

Danger!
Pull the power plug before doing any cleaning and maintenance work on the appliance.
Warning!
Wait until the compressor has completely cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying out any cleaning and maintenance work.
Danger!
After use, always switch off the equipment immediately and pull out the power plug.

8.1 Cleaning

  • Keep the safety devices free of dirt and dust as far as possible. Wipe the equipment with a clean cloth or blow it with compressed air at low pressure.

  • We recommend that you clean the appliance immediately after you use it.

  • Clean the appliance regularly with a damp cloth and some soft soap. Do not use cleaning agents or solvents; these may be aggressive to the plastic parts in the appliance.
    Ensure that no water can get into the interior of the appliance.

  • You must disconnect the hose and any spraying tools from the compressor before cleaning. Do not clean the compressor with water, solvents or the like.

8.2 Condensed water (Fig. 1)
Important! To ensure a long service life of the pressure vessel (2), drain off the condensed water by opening the drain screw (11) each time after using.
Check the pressure vessel for signs of rust and damage each time before using. Do not use the compressor with a damaged or rusty pressure vessel. If you discover any  damage, please contact the customer service workshop.

8.3 Safety valve (10)
The safety valve has been set for the highest permitted pressure of the pressure vessel. It is prohibited to adjust the safety valve or remove its seal. Actuate the safety valve from time to time to ensure that it works when required. To do so, open the screw cap of the valve while the tank is under pressure. Once the screw cap has been fully opened you must pull it to let air escape through the valve. Then screw the cap fully back in place.

8.4 Storage
Warning!
Pull the mains plug out of the socket and ventilate the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is secured in such a way that it cannot be started up again by any unauthorized person.
Warning!
Store the compressor only in a dry location which is not accessible to unauthorized persons.
Always store upright, never tilted!

8.5 Transport

  • Transport the equipment only by carrying it by the transport handle.
  • Protect the equipment against unexpected knocks and vibrations.

8.6 Ordering replacement parts:
Please quote the following data when ordering replacement parts:

  • Type of machine
  • Article number of the machine
  • Identification number of the machine
  • Replacement part number of the part required
    For our latest prices and information please go to www.Einhell- Service.com

Disposal and recycling

The equipment is supplied in packaging to prevent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and plastic. Never place defective equipment in your household refuse. The equipment should be taken to a suitable collection center for proper disposal. If you do not know the whereabouts of such a collection point, you should ask in your local council offices.

Possible causes of failure

Problem Cause Solution
The compressor does not start. 1.No supply voltage.

2.Insufficient supply voltage.
3.Outside temperature is too low.
4.Motor is overheated.| 1.Check the supply voltage, the pow-er plug and the socket-outlet.
2.Make sure that the extension cable is not too long. Use an extension cable with large enough wires.
3.Never operate with an outside temperature of below +5° C.
4.Allow the motor to cool down. If necessary, remedy the cause of the overheating.
The compressor starts but there is no pressure.| 1.The non-return valve leaks.
2.The seals are damaged.
3.The drain plug for condensation water leaks.| 1.Have a service center replace the non-return valve.
2.Check the seals and have any damaged seals replaced by a service center.
3.Tighten the screw by hand. Check the seal on the screw and replace if necessary.
The compressor starts, pressure is shown on the pres.- sure gauge, but the tools do not start.| 1.The hose connections have a leak.
2.A quick-lock coupling has a leak.
3.Insufficient pressure set on the pressure regulator.| 1.Check the compressed air hose and tools and replace if necessary.
2.Check the quick-lock coupling and replace if necessary.
3.Increase the set pressure with the pressure regulator.

**** For EU countries only
Never place any electric power tools in your household refuse.
To comply with European Directive 2012/19/EC concerning old electric and electronic equipment and its implementation in national laws, old electric power tools have to  be separated from other waste and disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request:
As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment must make sure that the equipment is properly disposed of if he no  longer wants to keep the equipment.
The old equipment can be returned to a suitable collection point that will dispose of the equipment in accordance with the national recycling and waste disposal regulations.  This does not apply to any accessories or aids without electrical components supplied with the old equipment.
Please note that batteries and lamps (e.g. light bulbs) must be removed from the tool before it is disposed of.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of  the Eichel Germany AG.
Subject to technical changes

Service information

We have competent service partners in all countries named on the guarantee cretic cate whose contact details can also be found on the guarantee certain cate. These partners  will help you with all service requests such as repairs, spare and wearing part orders or the purchase of consumables.
Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required for use as consumables.

Category Example
Wear parts* V-belt, air fi liter
Consumables*
Missing parts

* Not necessarily included in the scope of delivery!
In the effect of defects or faults, please register the problem on the internet at www.Einhell-Service.com.
Please ensure that you provide a precise description of the problem and answer the following questions in all cases:

  • Did the equipment work at all or was it defective from the beginning?
  • Did you notice anything (symptom or defect) prior to the failure?
  • What malfunction does the equipment have in your opinion (main symptom)?
    Describe this malfunction.

Warranty certificate

Dear Customer,
All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our  service department at the address shown on this guarantee card. You can also contact us by telephone using the service number shown.
Please note the following terms under which guarantee claims can be made:

  1. These guarantee terms apply to consumers only, i.e. natural persons intending to use this product neither for their commercial activities nor for any other self-employed activities. These warranty terms regulate additional warranty services, which the manufacturer mentioned below promises to buyers of its new products in addition to their statutory rights of guarantee. Your statutory guarantee claims are not affected by this guarantee. Our guarantee is free of charge to you.
  2. The warranty services cover only defects due to material or manufacturing faults on a product which you have bought from the manufacturer mentioned below and are limited to either the recti cation of said defects on the product or the replacement of the product, whichever we prefer. Please note that our devices are not designed for use in commercial, trade or professional applications. A guarantee contract will not be created if the device has been used by commercial, trade or industrial business or has been exposed to similar stresses during the guarantee period.
  3. The following are not covered by our guarantee: – Damage to the device caused by a failure to follow the assembly instructions or due to incorrect installation, a failure to follow the operating instructions (for example connecting it to an incorrect mains voltage or current type) or a failure to follow the maintenance and safety instructions or by exposing the device to abnormal environmental conditions or by lack of care and maintenance. – Damage to the device caused by abuse or incorrect use (for example overloading the device or the use or unapproved tools or accessories), ingress of foreign bodies into the device (such as sand, stones or dust, transport damage), the use of force or damage caused by external forces (for example by dropping it). – Damage to the device or parts of the device caused by normal or natural wear or tear or by normal use of the device.
  4. The guarantee is valid for a period of 24 months starting from the purchase date of the device. Guarantee claims should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed or parts fitted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fitted. This also applies if an on-site service is used.
  5. To make a claim under the guarantee, please register the defective device at: www.Einhell-Service.com. Please keep your bill of purchase or other proof of purchase for the new device. Devices that are returned without proof of purchase or without a rating plate shall not be covered by the guarantee, because appropriate identic cation will not be possible. If the defect is covered by our guarantee, then the item in question will either be repaired immediately and returned to you or we will send you a new replacement.

Of course, we are also happy offer a chargeable repair service for any defects which are not covered by the scope of this guarantee or for units which are no longer covered.  To take advantage of this service, please send the device to our service address.
Also refer to the restrictions of this warranty concerning wear parts, consumables and missing parts as set out in the service information in these operating instructions.
Declaration of conformity: We declare conformity in accordance with the EU directive and standards for article

*Compressor TC-AC 190/6/8 OF (Eichel)**

X 2014/29/EU
2005/32/EC2009/125/EC
(EU)2015/1188
2014/35/EU
2006/28/EC
X 2014/30/EU
2014/32/EU
2014/53/EU
X 2014/68/EU
(EU)2016/426
Noticed Body:
(EU)2016/425
X 2011/65/EU
(EU)2015/863
X 2006/42/EC
Annex IV
Notified Body:
Reg. No.:
X 2000/14/EC2005/88/EC
Annex V
X Annex VI
Noise: measured LWA
= 96 dB (A); guaranteed LWA
= 97 dB (A)
P = 1,2 kW; L/Ø = cm
Notified Body: INTERTEK DEUTSCHLAND GMBH (NB 0905)
2012/46/EU
(EU)2016/1628 Emission No.:
Standard references: EN 1012-1; EN 60204-1; EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3
Enshell Germany AG · Wiesenweg 22 · D-94405 Landau/Iskar
Landau/Iskar, den 10.05.2022

First CE: 18
Art.-No.: 40.206.55
I.-No.: 21012
Subject to change without notice
Archive-File/Record: NAPR027264
Documents registrar: Luca Peer
Wiesenweg 22, D-94405 Landau/Iskar Declaration of conformity

Declaration of conformity

We, Eichel UK Ltd
Champions Business Park, First Floor Unit 10, Arrowed Brook Rd, Upton, Worrall CH49 0AB, United Kingdom declare the conformity to UK standards and legislation was assessed for:
Air Compressor TC-AC 190/6/8 OF (Eichel)

UK legislation
Simple Pressure Vessels (Safety) Regulation
Electrical Equipment (Safety) Regulation
Radio Equipment Regulation Personal
Protective Equipment Regulation
The Ecodesign for Energy-Related Products and Energy Information Regulation
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulation
Noise Emission in the Environment by Equipment for use Outdoors Regulation
Electromagnetic Compatibility Regulation
Measuring Instruments Regulation
Pressure Equipment (Safety) Regulation
Annex V
X Annex VI
Noise: measured LWA = 96 dB (A); guaranteed LWA = 97 dB (A) P = 1,2 kW; L/Ø = cm
UK Approved Body: AnPCertifi cation Limited
Supply of Machinery (Safety) Regulation
Annex IV
UK Approved Body:
UKTE Cretic cate No.:
Standards: BS 1012-1; BS 620204-1; BS 55014-1; BS 55014-2; BS 61000-3-2; BS 61000-3-3
Worrall, 2022.05.10

Article Number: 40.206.55 I.-No.: 21012
Subject to change without notice
Archive-File/Record: NAPR027264
Documents registrar: Luca Peer
Wiesenweg 22, 94405 Landau/Iskar, Germany

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Einhell User Manuals

Related Manuals