horizont trapper AB15 Electric Fencer Instruction Manual

June 13, 2024
Horizont

horizont trapper AB15 Electric Fencer

Operating manual of the electric fence controller

„trapper AB15 – 10931“

In association with the installation and safety instructions for the SECURA ANIMAL or SECURA SECURITY electric fencers (www.horizont.com/securaanimal or www.horizont.com/securasecurity)

General Safety Instructions

Switch off the pasture fencer before coming into contact with it!
Operating manual information
The operating manual has some important instructions on handling the energizer. All technical details in the manual have been prepared and compiled with the greatest possible care. Even so, errors cannot be excluded. We wish to point out that we cannot assume any guarantee, legal responsibility or any liability for consequences attributable to possible lack of details. We would, at all times, welcome any notification of possible errors. Safe working depends on the indicated safety and handling instructions being adhered to. Also to be adhered to are those local accident prevention provisions which are in force where the energizer is used as well as the general safety requirements.
The operating manual is to be studied carefully before any work begins!
As an integral part of the overall product it is to be securely kept right next to the energizer and for ease of consultation by the personnel.
Do hand over this manual should this product be sold or passed on to another party. For a better understanding of what is involved, some of the diagrams in this manual may not be true-to-scale and may deviate slightly from the actual constructional design.

Description and Construction of the Product

The energizer transmits voltage pulses to a connected pasture fence.
Switching the energizer on and off (and changing between various operating modes) is undertaken by a push switch 1 .

Caution! Only the optional additional parts prescribed by the manufacturer are to be used.

Installation

Set up the energizer at a preferably moist location. The earthing rod supplied must be driven as deeply as possible into the ground at a moist location and connected by a high-voltage resistant connecting cable to the black earthing terminal ( ) of the energizer. Connect the high-voltage resistant fence cable to the red terminal with the lightning symbols . The energizer is only protected against moisture if it is properly installed. Shield the energizer from direct solar irradiation. Set the energizer up in a location where there is no fire hazard.

Solar panel installation ( <=20W):

Fasten the optional solar panel with the retaining plate at the energizer. The energizer has an incorporated solar charge regulator (when the energizer is switched on). Feed the cable into the housing through the cable inlet on the back of the energizer and connect in the housing lid. Make sure that the polarity is correct. Trouble-free solar operation is only possible in connection with a 9 V battery or a 12 V rechargeable battery! Align the energizer with the solar panel to face south. Use the lateral knurled nuts to determine and fix the alignment and angle position of the solar panel.
Align the device with the solar panel to face south. Operation with the solar panel means you cannot operate it with a mains adapter. The device has an incorporated solar charge regulator (when the device is switched on).

Earthing:

Good earthing of the fence is extremely important for trouble-free operation and optimum performance of the energizer; therefore it should be earthed at a preferably moist and overgrown location.
If the ground is dry and the fence is long, an additional earth conductor with intermediate earths (every 50 m) should be installed along the fence.
Installation with a 9V dry battery:
(use only alkaline batteries) Open the housing and insert the 9 volt dry battery. Connect the energizer to the 9V dry battery (red + / black -), ensure clean pole terminals and correct polarity. The energizer will not start if the polarity is reversed.
Installation with a 12V rechargeable battery: Connect the 12V rechargeable battery (red + / black -), ensure clean pole terminals and correct polarity. The device will not start if the polarity is reversed.

CAUTION!

**** Only use rechargeable 12 V batteries; only charge rechargeable batteries with ventilation in well-ventilated rooms. Disconnect the rechargeable battery from the energizer during the charging process. The rechargeable battery should be recharged before and after every use as well as during longer periods of storage (every 2 months) and disconnected from the energizer.
The energizer has an AUTO-ON function which ensures that as soon as power is connected the energizer starts to operate.

Commissioning

Switch on energizer with the push button 1 . After 1 second, you will hear a rhythmic even ticking of the pulses; the energizer is in operation. The energizer transmits pulses to the fence and the LED display lights up. The fact of the status LEDs not lighting up points to a defect in the power supply.

Checking the earthing

Provoke a short-circuit by driving a metal rod into the ground against the pasture fence wire (not plastic) about 50 m away from the pasture fencer.
The pasture fencer should now result in the lighting up of only a maximum 1 LED (moist ground) or of a maximum 2 LEDs (dry ground) (Fig. 5 LED 9 and 8). If this is not the case, then raise the number and / or length of the earth- ing posts.

Optimal Solar Alignment and Setting

The correct placement of the pasture fencer and the solar panel is crucial for the best possible operation of the energizer.

  1. Position the pasture fencer so that the panel points south. This positioning enables the panel to absorb a maximum amount of sunlight even during the few light winter days When placing the energizer, consider the position of the sun throughout the day and avoid a location which could cover the energizer with shade from trees, bushes or high grass.
  2. Determine the correct angle of inclination for the solar panel.
    The position of the sun above the horizon changes during the seasons. As a general recommendation, an angle of 50 degrees is optimal for long-term use in most parts of Europe. Nevertheless, the angle can be adjusted conditional upon the season to optimize the output of the solar panel for recharging the rechargeable battery (see Fig. below). The steeper the angle of inclination, the greater the cleaning effect during rain or snow.

Recommended setting angle of the panel South Europe / North Africa (South C

Empfohlener Anstellwinkel des Panels Nord- & Mitteleuropa (einschließlich A & CH)

It may be the case that in winter (except for southern Europe) there are not enough hours of sunshine to fully charge the rechargeable battery.
Regularly remove any deposits and dirt from the solar panel
This includes removing cut grass, dust (specifically along gravel paths), leaves and snow, since these can reduce the performance of the module for recharging the rechargeable battery.
Only check the rechargeable battery indicator in solar operation at dawn (without sunlight).

WARNING:
Do not leave the switched off pasture fencer in the sun with a rechargeable battery and a solar panel for a longer period. Why? This could damage the rechargeable battery.

Energizer Operating Description

Solar operation:
The solar panel produces electricity as soon as it is exposed to usable sunlight. The pasture fencer constantly requires electricity – by day as well as by night. The electricity generated in this way by the panel is stored in a rechargeable 12V battery, which means the energizer can operate without sunlight or can be supplied directly by a. 9V battery. The solar panel may not always have a sufficiently large output to fully recharge a rechargeable battery – especially in dark, grey and misty months (e.g. October to February).
For temperatures around 0 degrees centigrade or below, we recommend the use of a large 9 V alkaline battery instead of a 12 V rechargeable battery.
The energizer is operated primarily from the solar panel. If the solar panel does not have sufficient output, the energizer switches automatically to the connected 9 volt battery or to the 12 volt rechargeable battery.
Rechargeable battery indicator:
The rechargeable battery indicator provides information about the rechargeable battery or battery voltage. The solar display lights up constantly in green when the solar panel charging voltage is greater than the voltage of the rechargeable battery/ battery. Whilst the solar panel charges the 12V rechargeable battery, it does not charge the 9 volt battery.

Maintenance

Table 12 (9V battery)

| Flashing light| green| | Battery good
---|---|---|---|---
| Flashing light| red/green| | Replace battery
| Flashing light| red| | Battery fully depleted 9V battery – immediately replace

Replace the battery at the latest when 95% discharged (only 5% charge capacity left). The battery indicator (LED2) lights up:

Table 13 (12V rechargeable battery)

| Flashing light| green| | Rechargeable battery good
---|---|---|---|---
| Flashing light| red/ green| | Charge the battery
| Flashing light| red| | Rechargeable battery absolutely depleted

The rechargeable battery must be recharged at the latest when discharged down to 20% (only 80% charge capacity left) to prevent a flat battery. The rechargeable battery indicator (LED2) lights up:
Do note that temperature and measurement deviation may cause these figures to vary.

Caution!
When using a solar system Only carry out a battery or rechargeable battery test at start of the day ( no solar power supplied – cover panel )

Disassembly, Dismantling, Storage and Transport

Disassembly, Dismantling

Before starting disassembly:
●Switch off energizer
●Disconnect entire energy supply from the energizer.
● Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compatible manner.
Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety & environmental protection provisions in force.

Storage, Transport
Ensure that the energizer is both stored and transported only when switched off.

NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.

Faults and Repairs

WARNING!
Repairs may only be carried out by qualified persons.
Only the spare parts prescribed by the manufacturer may be used.

Subject to technical alterations!
The CONTROL LED (LED1) lights up green when the energizer is working trouble- free. If the LED lights red, there is a fault.

Table 14

Faults Display Corrective action
Battery under 15% capacity LED flashes alternately red/green Change

batteries
Battery under 5% capacity| LED flashes red| Change batteries
Rechargeable battery under 40% capacity| LED flashes alternately red/green| Charge the battery
Rechargeable battery under 20% capacity| LED flashes red| Charge the battery

OVERVIEW



Technical data

Input: 0,18 Joule

weight without batterie

max. fence line length

Declaration of Conformity

Warning: Do not connect to mains-operated equipment including battery chargers!

Instruction manual

Website
Discover our website and find more products, highlights, campaigns, movies, tips and more. We look forward to your visit!

www.horizont.com

Advisor electric fencing

By means of our electric fence advisor you can receive useful information about how to arrange a reliable electric fence
system.www.horizont.com/ACratgeberWeidezaun

Electric fencing catalogue

horizont offers a comprehensive range of electric fencing material. Please don´t hesitate to ask for a catalogue or have a look at our website to download it.

  www.horizont.com/ACkataloge

All data is made subject to sentences mistakes and literal mistakes, subject to product changes and falsity.
Reprint, even in extracts and use of the pictures only with written permission by horizont group gmbh.

Customer Support

horizont group gmbh
Animal Care
Homberger Weg 4-6
34497 KORBACH GERMANY
+49 (0) 56 31 / 5 65 – 1 00
+49 (0) 56 31 / 5 65 – 1 20
[email protected]
horizont.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Horizont User Manuals

Related Manuals