horizont Type 10864 Trapper N45 Instruction Manual

June 13, 2024
Horizont

horizont Type 10864 Trapper N45

horizont-Type-10864-Trapper-N45-product

Product Information

  • The trapper N45 is an energizer designed for transmitting voltage pulses to a connected pasture fence. It is compatible with the SECURA ANIMAL or SECURA SECURITY electric fencers.
  • The energizer should be installed in a location where there is no fire hazard and shielded from direct solar irradiation. It can be mounted on a wall or a stable post. Good earthing of the fence is crucial for trouble-free operation, and the energizer should be earthed at a preferably moist and overgrown location. Additional earth conductors should be installed along the fence if the ground is dry and the fence is long.
  • The energizer operates on a power supply unit and has an AUTO-ON function, starting automatically once it is connected to the mains network. It transmits pulses to the fence, and the LED display lights up to indicate its operation. If the status LEDs do not light up, there may be a defect in the power supply.
  • Maintenance of the energizer should be carried out regularly, considering temperature and measurement deviations that may affect its performance. When using a solar system, it is important to only carry out a battery or rechargeable battery test at the start of the day when no solar power is being supplied to the cover panel.
  • For disassembly, dismantling, storage, and transport, rechargeable batteries should be stored in ventilated and dry rooms.
  • Faults and repairs should only be handled by qualified persons, using spare parts prescribed by the manufacturer.

Product Usage Instructions

  1. Safety Precautions: Always switch off the pasture fencer before coming into contact with it.

  2. Installation:

    • Mount the energizer on a wall or stable post.
    • Drive the earthing rod (longitudinal rod) as deeply as possible into the ground at a moist location.
    • Connect the earthing rod to the earthing terminal of the energizer using a corrosion-resistant wire.
    • Connect the fence cable to the terminal with the lightning symbols.
    • Ensure the energizer is shielded from direct solar irradiation and not lying on the ground.
    • Place the energizer in a location without fire hazards.
  3. Commissioning: Insert the energizer’s mains plug into the power socket. The energizer will start automatically once connected to the power supply, indicated by a rhythmic ticking of pulses.

  4. Maintenance: Regularly check and maintain the energizer, considering temperature and measurement deviations that may affect its performance.

  5. Disassembly, Dismantling, Storage, and
    Transport:
    Store rechargeable batteries in ventilated and dry rooms during disassembly, dismantling, storage, and transport.

  6. Faults and Repairs: Only qualified persons should perform repairs using spare parts prescribed by the manufacturer.

Operating manual of the trapper N45
In association with the installation and safety instructions for the SECURA ANIMAL or SECURA SECURITY electric fencers ( www.horizont.com/securaanimal or www.horizont.com/securasecurity)

General Safety Instructions

Switch off the pasture fencer before coming into contact with it!

Operating manual information
  • The operating manual has some important instructions on handling the energizer. All technical details in the manual have been prepared and compiled with the greatest possible care. Even so, errors cannot be excluded. We wish to point out that we cannot assume any guarantee, legal responsibility or any liability for consequences attributable to possible lack of details. We would, at all times, welcome any notification of possible errors. Safe working depends on the indicated safety and handling instructions being adhered to. Also to be adhered to are those local accident prevention provisions which are in force where the energizer is used as well as the general safety requirements.
  • The operating manual is to be studied carefully before any work begins!
  • As an integral part of the overall product it is to be securely kept right next to the energizer and for ease of consultation by the personnel.
  • Do hand over this manual should this product be sold or passed on to another party. For a better understanding of what is involved, some of the diagrams in this manual may not be true-to-scale and may deviate slightly from the actual constructional design.

Description and Construction of the Product

  • The energizer transmits voltage pulses to a connected pasture fence.
  • Caution! Only the optional additional parts prescribed by the manufacturer are to be used.

Installation

  • The energizer can either be mounted on a wall or on a stable post. The earthing rod (longitudinal rod) must be driven as deeply as possible into the ground at a moist location and connected by a corrosion-resistant wire to the earthing terminal of the energizer.
  • Connect the fence cable to the terminal with the lightning symbols The energizer is only protected against moisture if it is properly installed. Shield the energizer from direct solar irradiation.
  • Do not operate the energizer when it lies on the ground. Set the energizer up in a location where there is no fire hazard.

Earthing:

  • Good earthing of the fence is extremely important for trouble-free operation and optimum performance of the energizer; therefore it should be earthed at a preferably moist and overgrown location.
  • If the ground is dry and the fence is long, an additional earth conductor with intermediate earths (every 50 m) should be installed along the fence.

Installation with 230V/110V:

  • Insert the energizer’s mains plug into the power socket.

CAUTION!

  • The energizer has an AUTO-ON function. As such, the energizer starts following connection to the mains network.
Commissioning
  • Commissioning – Power supply units:
  • Device starts automatically once it is connected to the power supply After 1 second, you will hear a rhythmic even ticking of the pulses; the device is in operation.

Energizer Operating Description

  • The energizer transmits pulses to the fence and the LED display lights up. The fact of the status LEDs not lighting up points to a defect in the power supply

Maintenance

  • Do note that temperature and measurement deviation may cause these figures to vary.

Caution!

  • When using a solar system
  • Only carry out a battery or rechargeable battery test at start of the day ( no solar power supplied – cover panel )

Disassembly, Dismantling, Storage and Transport

Disassembly, Dismantling

Before starting disassembly:

  • Switch off energizer
  • Disconnect entire energy supply from the energizer.
  • Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compatible manner.
  • Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety & environmental protection provisions in force.

Storage, Transport

  • Ensure that the energizer is both stored and transported only when switched off.

NOTE!

  • Ensure that rechargeable batteries are stored in ventilated and dry rooms.

Faults and Repairs

WARNING!

  • Repairs may only be carried out by qualified persons.
  • Only the spare parts prescribed by the manufacturer may be used.
  • Subject to technical alterations!

Spare parts

horizont-Type-10864-Trapper-N45-fig-2

Pos-Nr. trapper N45
1 84040
2 88128
4 88128RT
5 60625
6 607091
7 84041
8 94581

Installation and connection

horizont-
Type-10864-Trapper-N45-fig-3

Technical data

max. fence line length

Subject to technical alterations 0,74 kg

Total Weight

horizont-Type-10864-Trapper-N45-fig-6

Declaration of Conformity

horizont-
Type-10864-Trapper-N45-fig-7

Website

  • Discover our website and find more products, highlights, campaigns, movies, tips and more.
  • We look forward to your visit!
  • Entdecken Sie unsere Website und finden Sie weitere Artikel, Highlights, Aktionen, Filme, Tipps uvm.
  • Wir freuen uns auf Sie!
  • www.horizont.com
  • horizont group gmbh Animal Care
  • Homberger Weg 4-6
  • 34497 KORBACH GERMANY
  • + 49 (0) 56 31 / 5 65 – 1 00
  • + 49 (0) 56 31 / 5 65 – 1 20
  • [email protected]
  • horizont.com
  • All data is made subject to sentences mistakes and literal mistakes, subject to product changes and falsity.
  • Reprint, even in extracts and use of the pictures only with written permission by horizont group gmbh.
  • www.horizont.com/ACkataloge

Documents / Resources

| horizont Type 10864 Trapper N45 [pdf] Instruction Manual
Type 10864 Trapper N45, Type 10864, Trapper N45, N45
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Horizont User Manuals

Related Manuals