Push lightly on the snap lock with a finger or screwdriver (if mounted on the wall) to slide the backplate of the thermostat.
It is possible to connect a floor sensor to the thermostat (floor sensor not
incl.). Push gently on the terminals while you put the cable into the
terminal. The sensor must be drawn in a tube and the tip placed directly
beneath the top floor cover, in the middle between the floor-heating pipes.
Mount backplate on the wall (screws not incl.) thermostat slides onto the back
plate.
If you want to use the thermostat as a free-standing, the supplied foot can be
mounted in the back plate before it’s mounted again.
The thermostat can be connected to all Controllers in the Softline series.
Pairing/registering is made the same way on all Controllers using the same
buttons. On the pictures the panel of the Softline Controller, the master is
shown.
Pairing/registering the thermostat to a zone (channel). All connections must
be made to the Controller (pump, actuators and optionally potential free
relay) before start-up. Please see the controller manual for details.
Attention! Do not press the buttons on the front of the thermostat whilst
pushing the pairing button on the rear (see picture 11).
Roth gulvvarmesystem
Once the thermostat is connected to the Zone/Channel, the overview shows –
Temperatures on the thermostat (setpoint 22,0°C, actual 25,0°C), battery
(99%), signal strength (100% – must be at least 10%), and mode of operation
(CON = continuously). For more info on the display, see the controller manual.
Repeat registration for other thermostats, by choosing one of the other zones
(2 to 8) until the required number of thermostats are connected.
Attention! If a thermostat is paired to the wrong zone, do not delete the
thermostat. Pair the thermostat to the correct/new zone and the old pairing
will be deleted.
If the thermostat has a floor sensor connected, this must also be
paired/registered as shown below (picture 21, must be two quick
presses).
In the overview, you can see both the thermostat (setpoint 22,0°C, actual
25,0°C) and the actual floor temperature (21,0°C). Repeat this for all other
zones/channels (2 to 8) with a floor sensor.
The operation/setting of the floor sensor is carried out on the display of the
Controller. Floor sensor operation can be set up as either ”Floor protection”
(standard) or ”Comfort” (min. Floor temp.).
A set sensor as ”Floor protection”. Choose operation mode and choose ”Floor
protection”.
Set max. floor temperature to protect your floor Confirm with ”Menu”.
Set sensor as ”Comfort”.
Choose operation mode and choose ”Comfort”.
Set min. floor temperature for your comfort level. Confirm with ”Menu”. Min.
temperature is set as described above.
Attention! Using the floor sensor as ”Floor protection”, the sensor will
stop heating if the temperature goes above the set max. temperature. Below
this temperature the room sensor has priority. Using the floor sensor in
”Comfort” mode, the room sensor will have priority between min. and max.
setting. Outside this min/max setting the floor sensor has priority.
| In sleep mode, the current temperature is displayed. To set/change
temperature press < > buttons. Confirm by pressing or waiting 5 sec.
---|---
| You can switch between the temperature display and relative humidity display
by briefly pressing the button.
| You can choose between three modes on the thermostat. After changing the
setpoint with < / >
the actual setting is flashing: “Con” means setpoint is due constantly.
| “5H” means that the desired setpoint will be valid for the next 5 hours,
after this the thermostat
will return to it’s normal mode.
|
“OFF” means that it follows the mode preset on the Controller. The chosen mode
can also be
seen on the Controller display. Changing the mode ”Con”, ”5h” and ”OFF” is
done using the buttons < / > when the mode is flashing.
| Enables you to view battery levels. Select “Bat”, the display flashes.
Confirm within 5 sec. after which the battery level is displayed in percentage
%.
| Enables you to lock the buttons. Select “Yes” by using one of the buttons <
, confirm by pressing or waiting 5 seconds. When the lock is active, the keys are locked automatically after 10 seconds of inactivity. To unlock, press and hold the buttons < > for 10 sec. The keys are accessible when the display returns to show the current temperature. The key lock is activated until you inactivate it in the menu.
|
Enables you to return the room thermostat to the factory setting. Select “dEF” and the display flashes and shows the selected value. Select/confirm (Yes) with < > buttons within 5 sec. Confirm by pressing or wait 5 sec. and the factory settings has be restored.
| Enables you to view the sensor calibration value. After selecting ”Cal” the
screen flashes for 3 sec.
and the value is displayed. Value can be changed on the Controller, please see
user manual.
| Enables you to return from the MENU manually. After selecting ”rEt” the
screen flashes for 5 sec. and returns to view of the current temperature.
ROTH UK Ltd
1a Berkeley Business Park
Wainwright Road
Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mail enquiries@roth-uk.com
technical@roth-uk.com
orders@roth-uk.com
accounts@roth-uk.com
roth-uk.com
References
- borger.dk - din indgang til det offentlige
- Frontpage | Norge.no
- Hej! Welcome to sweden.se – the official website of Sweden
- UK.COM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>