profi-pumpe PSM01123VK FLOW Automatic Controller Instruction Manual

June 12, 2024
profi-Pumpe

profi-pumpe PSM01123VK FLOW Automatic Controller

profi-pumpe-PSM01123VK-FLOW-Automatic-Controller-
product

Product Information

The Flow Switch 6-2-1 is an automatic controller designed for use with non- abrasive clear water without deposits and dirt. It contains opto-electronic components that may malfunction if exposed to water containing iron or iron oxide. The unit has two operating modes: Quick-Stop and Normal-Stop. It also features an integrated non-return valve and must be installed vertically in the direction of flow for reliable operation.

Product Usage Instructions

  1. Before using the device, read the user manual for safety instructions and warnings.
  2. Ensure that the flow switch is installed by a qualified professional.
  3. Install the unit at any point between the pump outlet and the first outlet of the pump and consumer.
  4. Make sure the direction of the arrow on the side of the unit corresponds to the direction of flow in the pipe.
  5. Seal all water-carrying pipes and connections with sealing thread or adhesive. Do not use hemp or other sealants that can impair the function of the non-return valve.
  6. Ensure that the connections on the suction and pressure sides are completely tight.
  7. If using a pump with a maximum pressure of more than 10 bar, install a pressure reducer at the installation point of the switchgear.
  8. Switching between operating mode 1 (Quick-Stop) and mode 2 (Normal-Stop) is done by pressing the Start key for longer than 6 seconds. The Mode LED will light up in green for mode 1 and red for mode 2. Note that switching is only possible when water is flowing through the unit.
  9. If heavy condensation is expected or there is a risk of ice formation due to low ambient temperatures, it is recommended to protect the control unit and the pump accordingly.
  10. Ensure that the data on the type plate correspond to the intended operating conditions before operating the unit. If in doubt, do not operate the unit.
  11. Report any transport damage to the shipping company and the manufacturer in writing without delay.

SAFETY INSTRUCTION AND WARNINGS

  • Please read the user manual before using the device
  • Warning sign
  • Pull power plug
  • Warning of electrical voltage

  INTRODUCTION

We would like to congratulate you on the purchase of our flow switch. We appreciate your trust. That‘s why functional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper use of the 6-2-1 Failure to follow the instructions and safety precautions can result in injury or property damage.
Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www.profi-pumpe.de under „downloads“. This shall always prevail.

IN GENERAL

  • The flow monitor 6-2-1 is a control unit for the automatic operation of electric pumps that generate a delivery pressure of at least 2.5 bar. The flow monitor 6-2-1 switches the pump „ON“ and „OFF“ according to demand. The flow monitor 6-2-1 switches the pump off when there is no water in the line and thus protects it from damage due to dry running. The control unit can automatically restart the pump via an integrated timer to check whether there is water again (only for the versions with automatic reset). A pressure gauge ensures control of the switch-on pressure and the system pressure. In addition, possible leaks can be detected in good time by means of the manometer.
  • The flow monitor 6-2-1 is to be used exclusively for non-abrasive clear water without deposits and other dirt. If this is not the case, an effective pre-filter with a mesh size of no more than 0.2 mm must be installed upstream of the unit. The unit contains opto-electronic components that may malfunction if exposed to water containing iron or iron oxide.
  • It is not advisable to install the unit in wells or in localities where heavy condensation could occur. This will cause damage within a short time due to voltage flashover in the unit. If there is a risk of ice forming due to low ambient temperatures, it is recommended to protect the 6-2-1 control unit and the pump accordingly.

IMPORTANT!

  • The flow monitor 6-2-1 has 2 different operating modes. Switching from operating mode 1 (Quick-Stop) to 2 (Normal-Stop) is done by pressing the “Start“ key for a longer time (>6sec). In operating mode 1, the “Mode“ LED lights up in “green“, in operating mode 2, the “Mode“ LED lights up in red. Switching is only possible when water is flowing through the unit.

  • The switchgear has an integrated non-return valve. The flow monitor 6-2-1 must be installed vertically in the direction of flow, so that the check valve can work reliably. Another
    non-return valve between the pump and the flow switch 6-2-1 can lead to malfunctions and is not permitted.

  • After unpacking, make sure that the data on the type plate correspond to the intended
    operating conditions. In case of doubt, do not operate the unit. In case of damage caused by non-observance of the operating conditions, the claim to legal warranty is void. Transport damage must be reported to the shipping company and to us in writing without delay.

INSTALLATION

The installation must be performed by a qualified professional.

profi-pumpe-PSM01123VK-FLOW-Automatic-Controller-
\(1\)

  • The unit can be installed at any point between the pump outlet and the first outlet of the pump and the first consumer. The direction of the arrow on the side between the two connections must correspond to the direction of flow of the liquid in the pipe. All water-carrying pipes and connections may only be sealed with sealing thread, better with
    adhesive. The use of hemp or other sealants, the residues of which can come loose on the inside and impair the
    function of the non-return valve, is prohibited.

  • Make sure that the connections on the suction and pressure sides are completely tight. If a pump with a maximum
    pressure of more than 10 bar is used at the installation point of the switchgear, a pressure reducer must be installed at the inlet of the unit. The pump control unit is only to be used for pumps that generate a minimum pressure of 2.5 bar at the point of installation of the unit.

  • The electrical connection of the unwired version is to be made according to the electrical diagram (see Fig. 4). If a consumer with a power of more than 1.1 kW is used and the room temperature is higher than 25°C, the wiring must be cables with a heat resistance of not less than 99°C must be used for the wiring. For wiring, use only the pliers designed for this purpose. Make sure that the earth cable is connected in a functionally safe way. In the case of the factory prewired version with plug and socket, it is sufficient to the mains plug of the pump to the socket of the 6-2-1 and connect the mains plug of the 6-2-1 to a mains socket of the mains supply.

  • The centrifugal pump and the suction pipe must be filled with water
    manually. In the case of deep well pumps, wait until the air has escaped from the pump. Before connecting the flow monitor
    6-2-1, check the function of the pump. Once you are satisfied that the pump is functioning properly, you can proceed with the installation of the pump control 6-2-1. When voltage is applied, the LEDs “Mode“ (“green“ for mode 1 or “red“ for mode 2) and “Status“ light up in “yellow“. Press the “Start“ button to start the pump for the first time. The pressure line fills with water. After the residual air is displaced from the water pipes, pressure builds up. When starting up for the first time, it may be necessary to repeat the procedure several times in succession and to start the pump by pressing the “Start“ button. Once the pressure has built up and no more water is being pumped, the pump switches off automatically. If mode 1 (mode LED in green) is selected, the pump is switched off approx. 3 seconds after the shut-off pressure is reached and the yellow “Status“ LED goes out. If mode 2 (mode LED in red) is selected, the pump is switched off approx. 8 sec after the shut-off
    pressure is reached and the yellow “Status“ LED goes out.

Switching from operating mode 1 (Quick-Stop) to 2 (Normal-Stop) is done by pressing the “Start“ key for a longer time (>6sec).

  • There must be no pressure drop when the tapping points are closed (water tap). If a consumer is opened, the pump must start automatically. The pressure at which the unit starts is usually preset; this switch-on pressure of 1.5 bar is optimal for most applications. It can be changed by a specialist. When setting the cut-in pressure, the highest water tapping point must be taken into account, as this determines the static pre-pressure through the water column. The highest water extraction point must not be greater than X m (specific data as shown in Fig. dure 2). For specific installation see figure 1. To set the cut-in pressure, please proceed as follows: When the pump has switched off automatically, the pressure gauge shows a certain value and this value does not change, carefully and slowly open a consumer (water tap). The pressure display on the manometer slowly moves towards “0“. When the water pressure reaches 1.5 bar, the pump switches on and the original pressure value is reached again. Now carefully turn the screw “START PRESSURE SETTING“ a little clockwise to the right with a screwdriver. Now carefully and slowly open the tapping point (water tap) again and observe the manometer display. The pump will now switch on automatically at a higher water pressure. If the switch-on pressure is to be reduced, turn the adjusting screw counterclockwise (to the left). By repeatedly turning the screw “START PRESSURE SETTING“, you can now set the desired switch-on pressure. Proceed in the same way if you want to set the cut-off pressure. Now, however, observe the shut-off pressure and turn the “SHUT-OFF PRESSURE SETTING“ screw until the desired shut-off pressure is reached.

Warning: no additional check valve should be installed between the pump and the 6-2-1, as it sometimes causes problems.

profi-pumpe-PSM01123VK-FLOW-Automatic-Controller-
\(2\)

Starting pressure (bar)

| Height difference (Xmax.) between the highest water tapping point and the installation point of the pressure switch|

Minimum delivery head / Minimum pump pressure

---|---|---
0.8| 8 m| Greater than 20 m / 2 bar
1.2| 12 m| Greater than 22 m / 2,2 bar
1.5| 15 m| Greater than 25 m / 2,5 bar
2.2| 22 m| Greater than 32m / 3,2 bar

profi-pumpe-PSM01123VK-FLOW-Automatic-Controller-
\(3\)

  • Connect to single-phase 220V, the maximum power of 1.1 kW pump wiring diagram.
  • Due to the pump controller connected to a 220V single-phase, the power is greater than 1.1 kW water pump of the circuit diagram. Contactor coil specification for AC 220V control capacity should not be less than 4 kW.
  • Due to the contactor controllers connected to a 380V three-phase, power is greater than 1.1 kW water pump of the wiring diagram. Contactor coil specification for AC 220V control capacity should not be less 4 kW.

OPERATION

Regular pump operation:
Fill the centrifugal pump and the suction pipe with water. In the case of deep well pumps, wait until the air has escaped from the pump. The pump is started for the first time by pressing the “Start“ flow monitor (DW) 6-2-1 key. The pressure line fills with water. If no more water is delivered, the pump is switched off.

  • The consumer is open: The pump remains switched on, water flows.
  • The consumer is closed: The pump builds up the water pressure in the line and switches off depending on the set operating mode “Mode“.
    For proper operation, the max. pressure of the pump must be at least 0.6 bar above the set switch-on pressure. The switch-on pressure is usually preset at the factory to 1.5 bar, an optimum value for most applications. Make sure that the distance between the cut-in and cut-off pressures is not too small. Otherwise, this may cause the pump to cycle and possibly damage it.

Mode 1-“Quick-Stop“:
When the switch-off pressure set on the DW is reached, the DW switches off after approx. 3 sec. The yellow “Status“ LED goes out. When the consumer draws off water and thus the pressure in the line and DW drops, the DW switches the pump on when the switch-on pressure is reached. The DW will always try to maintain pressure in the consumer-side line. The cut-off pressure in mode 1 can be set almost to the max. pump pressure. However, it should be approx. 0.3-0.5bar lower than the maximum pump pressure. E.g. if the max. pump pressure is 4bar, the cut-off pressure can be set to approx. 3.5-3.7bar.

Mode 1-“Normal“:
After the DW detects that the water is no longer flowing, the pump stops operating after approx. 8 sec. and the yellow LED goes off. The shut-off pressure in mode 2 is set significantly lower than the max. pump pressure. It should be approx. 0.5-0.8bar lower than the maximum pump pressure. E.g. if the max. pump pressure is 4bar, the cut-off pressure can be set to approx. 3.2-3.5bar.
Mode 2 is always preferable to mode 1 as the unit will operate more safely under all conditions.

Dry run protection:
The dry run protection function protects the pump from running dry without cooling. The flow monitor (DW) registers when no water is flowing through the unit. This can happen if no water is available “suction side“ or if air is drawn “suction side“ due to a pipe leak. When this problem is detected, the “Status“ LED flashes in yellow. This indicates a fault and the DW switches off the pump. Since there is a fault, it must first be eliminated and then the pump restarted by pressing the “Start“ button on the DW.

The 6-2-1 control is able to detect pump faults, leakages and pump failures as well as pump cycling. If the “Status“ LED flashes, this is an indication that there is a problem in the pipe or with the pump. The DW can also detect when the water pressure in the piping system decreases or increases. If no water is being pumped in the system or there is another problem, the “Status“ LED flashes. The DW 6-2-1 switches on automatically when water is present in the piping system again. Alternatively, the user can click on “Restart“ to switch on the control.

protection function against frequent switching on / cycling of the pump
If the water pump is switched on and then switched off almost immediately afterwards, this is registered and evaluated by the 6-2-1 control. If the stop/start time interval is less than 15 seconds, the cycle counting starts. After 30 cycles (start/stop), the pump is switched off and only switched on again automatically after 30 minutes. The corresponding “MODE“ LED flashes. The main purpose of this function is to prevent damage caused by improper use, which can lead to overheating of the pump.

RECOGNISING AND REPAIRING OF MISTAKES

Problem Possible cause Solution
The pump perma- nently switches “on“ and “off“ (Pump clocked) The
system has leaks. Internal check valve may leak Vent system

Check system to dripping pipes / faucets / valves.
Check non-return valve in the unit for leaks


The pump will not start

|

  • No mains voltage present
  • Too much difference in height between the device and a customer (faucets)
  • The pump is defective
  • Malfunction of the device

| ****

  • Check the electrical connections
  • Reduce height difference
  • Contact a qualified technician
  • Contact the merchant

The pump will not stop

|

  • The system has greater lea- kages
  • Malfunction of the device
  • Internal check valve is dirty

|

  • Check the system
  • contact the dealer
  • Pump + Rinse machine (see 6)

The “Status“

red light flashing

|

  • Water shortage
  • Damage of the pump
  • The pump inlet divulge
  • Set stop pressure is greater than the maximum head of the pump

|

  • Water shortage
  • Damage of the pump
  • The pump inlet divulge
  • Set stop pressure is greater than
  • the maximum head of the pump

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
  • To avoid shocks and fire risks, read and follow closely the following instructions:
    • Always unplug the device from the mains before carrying out any work on it.
    • Be sure that the electric line connecting the device to the mains and the extension leads have a cross-section suitable for pump power and be sure that the electrical connections are far away from any water source
    • When Flow guard is used for swimming pools, ponds and fountains if is necessary to use an automatic RCD with IDn = 3OmA protection.

Warning: when the pump stops the pipes are under pressure consequently we recommend opening a faucet to discharge the system before carrying out any work.

  • The electrical connections are always to be carried out by an authorized professional.
  • The 6-2-1 may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
  • Cleaning and maintenance must not be carried out by children without supervision.
  • The pump must not be used or operated under any circumstances when there are
    people in the same water.

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
  • To reject every responsibility for the damages which originate from the improper use of the device.

SERVICING

It may happen occasionally that dirt is retained in the internal check valve and this is no longer seals 100%. The first remedy should be always trying to flush the check valve free. For this pur-pose, eg. As the Garden side faucet on full blast, so that the pump at full rated power promotes about 30 minutes water. Is then the timing is not clear, the unit must be replaced. Prior to installati-on of the new device, the pump is in, free to flush any case, as previously described. Opening the device on non-return valve is prohibited and always results in the loss of any existing warranty. In addition, persons could be dangerous when Operating a clocking pump occur, so that the pump may be operated under any circumstances continue. Until the device replacement, the pump must be taken out of service. For abrasive materials such as sand, shortening the Maintenance period and the device lifetime.
The following checks should be carried out regularly:

  • functional test (min. every 3 months)
  • integrity of the power cord
  • Clean the guide lines (eg no buckling)
  • Clean the media (no sand, no sludge)

GUARANTEE REGULATIONS / STATUTORY WARRANTY

For all manufacturing and material defects, the statutory warranty applies. In these cases, we assume the exchange or appliance repairs. Shipping costs are borne by us only to the extent legally is prescribed.
In the event of a warranty claim, please register the case via our service platform http://www.profi-pumpe.de/service.php
Then we will inform you how to proceed with case by case basis.
Returns please sufficient postage. Unfortunately prepaid returns will not be accepted, because they are filtered out before delivery. Our service we provide in Germany. The warranty does not cover:

  • Improper installation (proper installation, unauthorized persons)
  • Material wear (eg. seals) or dirt in the unit
  • Unjustified interventions or changes in the device
  • Damages by selffault
  • Improper servicing and improper use
  • Moreover, we give no damage compensation for secondary damages!

NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE 79535656.
This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electri-cal devices. This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!

EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely Durchflusswächter 6-2-1 Automatic- Controller as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised direc-tives and the EU standard for safety. This declaration of conformity applies insofar as no modifi-cations are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.

The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
Low Voltage Directive (2014/35/EU)
EC Electromagnetic compatibility directive (2014/30/EU)

The following harmonized standards:
EN 60730-1:2016, EN 60730-2-6:2016, EN 55014-1:2017, EN 55014-2:2015,
EN 61000-3-2:2014, EN 61000-3-3:2013

Signed for and on behalf of:
Amur S.à r.l.
Remich, 17.02.2023
i.V. Dipl. Phys. Peter Neumüller Technical Manager

profi-pumpe-PSM01123VK-FLOW-Automatic-Controller-