PROJECTA IG2-BT7 High Powered Management with Bluetooth Monitor Instruction Manual
- June 12, 2024
- Projecta
Table of Contents
INTELLI-GRID 12V 2000/3000W
HIGH POWERED MANAGEMENT
WITH BLUETOOTH MONITOR P/No
IG2-BT7, IG3-BT7
SYSTEM INTRODUCTION
The IG2/3-BT7 is a 2000W/3000W power solution for all your power, lighting and water requirements. This system monitors the status of the tyres and the level of the RV while also tracking the gas cylinders. It is connected to a color display with Bluetooth, so you can check and control the system from your phone.
SYSTEM COMPONENTS
- 7” Monitor with App
- 2KW/3KW Inverter/Charger with AC change over swtich
- MPPT Solar controller
- DC-DC Charger
- Controller Box
- Constant Output Module with 12 outputs
- Auxiliaries Controller with 9 outputs & Water Tank Measurement
- Lights Module with 6 outputs
- 200Ah/400Ah Lithium Battery
- Wireless Switch (Not supplied)
- 4 Water tank sensors (Not supplied)
PAB – FRONT: 950 x 370 x 160mm
PAB – BACK
KEY FEATURES
INVERTER & GRID POWER
2000/3000W inverter with 120/180Amp charging, grid power booster and AC
transfer switch.
AS/NZS 3001 ready
LITHIUM BATTERY
An advanced and powerful 200/400Ah lithium battery perfectly matched to the
Intelli-Grid system provides the ultimate power for off gird requirements
BLUETOOTH MONITOR
Bluetooth 7” Colour monitor showing SOC, full control of the RV, its water,
lighting and hardware
MULTIPLE CHARGING OPTIONS
30/60A DC-DC charging and 40A MPPT solar charging for charging from vehicle or
when sun is shining
SOLAR CHARGING WAKING UP
When this feature is set to enable, the system can wake up and be solar
charged automatically as long as the sun is shining even when the system is
OFF
LOW VOLTAGE PROTECTION
Multiple strategies for low voltage protection of service batteries to avoid
failure of lithium batteries by over-discharge
MONITORING THE 7” COLOUR DISPLAY INTRODUCTION
The above is the home page, the details are as follows:
-
Region 1: Area for time and date display.
-
Region 2: Indoor and Outdoor temperature display area.
-
Region 3: Area for showing battery information.
In this area, the user can see the battery power data and status. It contains the following points:
a) Check the batteries are charging or discharging.
b) Check the batteries voltage and current.
c) Check the batteries SOC value.
d) Check the time to go or time to full of batteries. -
Region 4: Area of shortcut keys.
a) PWR: All DC and AC outputs turned on/off with this key. Only the constant live output of IGCMD and the class C3 output of C12 are retained.
b) Inverter: Inverter charger ON/OFF switch.
c) HWS: Water heater ON/OFF switch.
d) Pump: Water pump ON/OFF switch. -
Region 5: Water tank level display area.
a) If the fresh water is lower than the warning value, the alarm is triggered.
b) If the gray or black water is greater than the warning value, the alarm is triggered. -
Region 6: Scene mode.
a) ECO mode: System will enter “ECO” Mode automatically after being started. When SOC drops to 15% (it is settable within 15% – 20%), the system shuts down the inverter outputs and the heavy loads, keeping ONLY the essential loads on.
i. Typically fridge, ceiling light and a spare output is ON. Only the constant live output of IGCMD are ON, such as Fridge and USB.
ii. Pump, spot FR&BK, bedroom light can be turned ON manually.
iii. One group of the C12 outputs (marked as C3) is ON.
When SOC is back to 15% (or other setting value) + 3% or there is AC grid charging, system exits ECO mode automatically. Customer can also exit the mode manually
b) Night mode: Designed for a silent environment for customers. It can be activated at the front page of 7” screen. When entering the mode,
i. The system will shut down the lights and the back lights of the screens.
ii. De-rate the charging current of inverter/charger to reduce the fan noise.
c) Light off: This mode is designed for turning off the all lights with one key. -
Region 7: Gas level display area.
-
Region 8: Charging source information display area.
In this area, the user can check the charging data as follows:
a) Inverter/Charger:
i. Display output voltage, power and load rate.
ii. The user can select the AC input source.
“Mains” means the source is grid, “Gen” means it is generator.
b) Vehicle charger: Checks the output current and power of vehicle charger.
c) Solar charger: Checks the output current and power of vehicle charger -
Region 9: Navigation area.
Note:
a) The icon will turn white when switched to the corresponding page.
b) When the alarm icon is red, it means that one or more alarms exist. After the alarm is removed, the icon turns to gray.
Load Control Page
The load control page displays all switchable outputs with their functions named. When the load is turned on, the load icon is white with a green dot in the upper right corner. If the load is turned off, the icon turns gray and the green dot disappears.
Sensor Page
6 .3.1 Leveling
Ensures your RV is level when parked. 6 .3.2 TPMS
Monitors tyre pressure to prevent premature wear with high / low warning
setting.6 .3.3 GAS sensor
Monitors the level of gas available within the gas cylinders.
Setting Page
The setting menu allows the user to make basic changes to the system, including:
-
Screen setting.
The user can set screen brightness level, time and date, sleep time, buzzer enable, temperature unit and language selection.
-
Rename.
In this page, the load and water tank can be renamed.
Further, the icon also can be changed when renaming the load.
-
System.
The user can engage the ‘Solar Automatic Wake Up Function’ as well as disengage the ‘Ground Relay’.
WARNING: Ground relay MUST be left on for correct RCD operation.
-
Firmware.
Displays all software revisions of available components.
-
QR code information.
After running the app, users can directly scan the QR code to log in without entering the user name and password.
System Updating
This system can be upgraded via a USB stick. First, copy the files that need
to be updated to a USB stick and place them all in a folder named IDM. Insert
the USB stick into the U disk port located on the back of 7” screen. The
upgrade dialogue box will pop up on the 7” screen as shown right.
The ‘Screen’ selection refers to updating the 7” display files while ‘Device’
refers to system components such as IGCMD, IGCOM, etc. After selecting the
correct update action, update each piece of software, one at a time. Power
must not be turned off or removed from the system during update process.
The latest software will be available at
www.projecta.com.au
Data Analysis
In Region 3 and Region 8 on the main display, double click the corresponding icon to enter the data analysis page. The screen can display the history data of multiple devices in the system.
-
Battery
-
Vehicle Charger
-
Solar
-
Inverter Charger
COMPONENT SPECIFICATIONS
INVCHR2 & INVCHR3
2000W/3000W 12V INVERTER/CHARGER
Perfect for powering the most demanding 240V appliances on the go this
inverter/charger is ideal for operating on or off the grid. An RCD is included
to ensure maximum safety for the unit and operator.
The inverter/charger is fitted with grid power boost which is great if the
shore power or generator is weak.
Grid power boost will supplement the shore power to ensure all your appliance
can run.
SPECIFICATIONS
PART NO INVCHR2| INVCHR3
240V CHARGING|
CHARGE TYPE| 5 Stage Automatic
INPUT| 240VAC, 50/60Hz, 32A(MAX)
OUTPUT| 12V, 120A| 12V, 180A
BATTERIES SUPPORTED| GEL, AGM, WET, Lithium
TEMPERATURE COMPENSATION| YES
INVERTER|
INPUT| 12V (10.5V~17V)
OUTPUT| 220/230/240 VAC
FREQUENCY| 50/60 Hz
OUTPUT POWER| 2000W (4000W peak)| 3000W (6000W peak)
GRID BOOST OUPUT| 24Amps, Mains Supply
+ 8.3Amps Inverter RCBO limited to 16Amps max.| 28Amps, Mains Supply +
12.5Amps Inverter RCBO limited to 16Amps max.
AC TRANSFER| <2m Sec
OPERATING TEMPERATURE| -20°C ~ 65°C
WEIGHT| 17KG| 21KG
IP RATING| IP20
SIGNAL TERMINAL INTRODUCTION
NO. | LABEL | DEFINITION |
---|---|---|
1 | Bat Sample | Battery temperature and voltage sample. |
2 | Remote | A dry contact input for remote on/off, often IGN was connected. |
3 | Com MON | RS485 port for external monitor such as INVCHRD-BT. |
4 | Com Sync | Communication with PROJECTA’s LB-HD series lithium battery, which |
is able to synchronize lithium battery’s charging and discharging strategy
5| Relay1| Dry contact output control 1(NO,C,NC)
(NO,C,NC)
6| Relay2| Dry contact output control 2(NO,C,NC)
(NO,C,NC)
7| S+| Slave charger for starter battery
SC540
5 STAGE MPPT SOLAR CHARGER CONTROLLER WITH 100V INPUT
Get the most out of your solar array using these Maximum Power Point Tracking
(MPPT) solar controllers increasing the charging output by up to 30% (compared
to PWM Solar controllers).
SPECIFICATIONS
PART NO| SC540
BATTERY VOLTAGE| 12/24/48V
MAXIMUM SOLAR VOLTAGE| 100V
STANDBY CURRENT| 1mA 12V
CHARGER TYPE| 5 Stage
INPUT| 100V
CONTROL TYPE| MPPT
BATTERIES SUPPORTED| GEL, AGM, WET, Lithium
TEMPERATURE COMPENSATION| Yes
COMMUNICATION| RS485
STORAGE TEMPERATURE| -40°C ~ 70°C
HUMIDITY| 5 – 95%
IP RATING| IP31
WEIGHT| 1.4KG
COOLING| Convection
LABEL DEFINITION
PV| +| Connection terminal for PV array Positive
–| Connection terminal for PV array Negative
BAT| +| Connection terminal for Battery Positive
–| Connection terminal for Battery Negative
EPO| EPO contacts, defined for remote on/off.
NC| Output dry contacts.
C
NO
RS485| Connection terminal for RS485 communication.
Temp. Sensor| Connection terminal for battery temperature sensor.
PIN DEFINITION OF TEMP SENSOR
PIN | DEFINITION |
---|---|
Pin 1 | Battery Positive |
Pin 2 | Battery Negative |
Pin 3 | Temperature sensor |
Pin 4 | Battery Negative |
PIN DEFINITION OF RS485 COMMUNICATION PORT
PIN | DEFINITION |
---|---|
Pin 1 | |
Pin 2 | |
Pin 3 | RS485_A |
Pin 4 | |
Pin 5 | |
Pin 6 | RS485_B |
Pin 7 | |
Pin 8 |
PMDCS30
DC-DC 12V CHARGER
Smart DC to DC chargers specifically designed for Intelli-RV and Intelli-
Grid.
SPECIFICATIONS
PART NO | PMDCS30 |
---|---|
CHARGER TYPE | 5 Stage |
ALTERNATOR INPUT VOLTAGE | 12–16V |
OUTPUT | 12V, <30A |
BATTERIES SUPPORTED | GEL, AGM, WET, Lithium |
STORAGE TEMPERATURE | -40°C ~ 70°C |
OPERATING TEMPERATURE | -40°C ~ 70°C |
IP RATING | IP20 |
WEIGHT | 1.0KG |
COOLING | Convection |
SMART ALTERNATOR | Turn on: 12.2V Turn off: 11.9V |
CONVENTIONAL | Turn on: 13.2V Turn off: 12.8V |
CONNECTORS AND TERMINALS
Connectors and terminals guide
No.| Print| PMDCS30| Remarks| Circuit colours and
labelling
---|---|---|---|---
1| Alternator| Connects to positive of Alternator| Connects to positive
battery post| Red + Label “Aux+”
BAT-| Connects to negative of Alternator| Connects to negative battery post|
Black – Label “Aux-”
2| AUX BAT| Connects to positive of auxiliary battery| | Red + Label “Vehicle
Batt+”
BAT-| Connects to negative and negative of auxiliary battery| | Black – Label
“Vehicle Batt-”
3| COM| For communication of RS485| Not Connected|
4| 1| Not used| Details of setting can be found as Chapter 4.6|
2| Set on for 30Amp, off for 15Amps
3| Used to set battery chemistry
4
5| BAT-| Connects to BTS’ black cable| For battery temperature sensing| RED
Ring Terminal connect to Battery +ve
Temp| Connects to BTS’ white cable
V-Sen| Connects to BTS’ red cable| For voltage sensing
Fuse specification
No.| Print| Specification| Colour| Quantity|
Protection for
---|---|---|---|---|---
6| Alternator| 30A/32VDC for PMDCS30| Amber| 2| Input from alternator
7| AUX BAT| 20A/32VDC| Yellow| 2| Output to charge auxiliary battery
IGCMD
INTELLI-GRID AUXILIARIES CONTROLLER
This is the input and output controller, with water sensors and switchable
devices being connected with built in fused outputs.
SPECIFICATIONS
PART NO| IGCMD
INPUT VOLTAGE| 9~32V
INPUT CURRENT| <60A
OUTPUTS| 2 x 15A Relay with Bypass, 7 x 15A Relay, 4 x Dry contact
INPUTS| 4 x Dry contact, 4 x conductive water measurement
COMMUNICATION| CAN bus, RS485, RF
OUTPUT
A5-1| A5-2| A5-3| A5-4| A5-5| A1-1
A1-2| GND| GND| GND| GND| A5-6
GND| GND| GND| GND| GND| A5-7
OUTPUTS| FUSE| OUTPUT LABEL| DEVICES
---|---|---|---
A5-6 (15A)| A5-6 (15A)| Spare 1|
A5-7 (15A)| A5-7 (15A)| Spare 2|
A5-1 (15A)| A5-1 (15A)| Spare 3|
A5-2 (15A)| A5-2 (15A)| Media| TV & Stereo &
A5-3 (15A)| A5-3 (15A)| Fans & 12V| Fan & USB, 12 Sockets
A5-4 (15A)| A5-4 (15A)| HWS| Hot water service
A5-5 (15A)| A5-5 (15A)| Heater| Diesel heater if fitted
A1-1 (15A) With optional Bypass fuse| A1-1 (15A)| PUMP 1| Pump 1
A1-2 (15A) With optional Bypass fuse| A1-2 (15A)| PUMP 2| Pump 2
Water Sensor 1| | Tap 1| Tank 1
Water Sensor 2| | Tap 2| Tank 2
Water Sensor 3
Water Sensor 4| | Waste| Tank 3
PMWLM6
6 CHANNEL OUTPUT MODULE
This 6 channel output module works with wireless switches and can also be
controlled via the 4”, 7” screen or phone app.
SPECIFICATIONS
PART NO| PMWLM6
INPUT VOLTAGE| 9~16V
MAXIMUM INPUT CURRENT| <60A
STANDBY CURRENT DRAW| 3mA
OUTPUTS| 6 x 15A Relay
WORKING TEMPERATURE| -40°C ~ 80°C
IP RATING| IP20
CONNECTORS AND TERMINALS
POWER INPUT TERMINAL DEFINITION
PIN NO| PIN DEFINITION| POLARITY| VOLTAGE RANGE|
RATED CURRENT
---|---|---|---|---
1| BAT+| BAT+| 9–16V| 30A
2| BAT+| BAT+| 9–16V| 30A
3| BAT-| BAT-| |
4| BAT-| BAT-| |
OUTPUT TERMINAL DEFINITION
OUTPUT
L1| L2| L3| L4| L5
GND| GND| GND| GND| L6
GND| GND| GND| GND| GND
PIN DIAGRAM
PIN NO| PIN DEFINITION| FUSE| CURRENT RANGE|
VOLTAGE RANGE
---|---|---|---|---
1| L1| L1 15A| 0–10A| 0-16V
2| GND| | 0–15A| 0-16V
3| GND| | 0–15A| 0-16V
4| L2| L2 15A| 0–15A| 0-16V
5| GND| | 0–15A| 0-16V
6| GND| | 0–15A| 0-16V
7| L3| L3 15A| 0–15A| 0-16V
8| GND| | 0–15A| 0-16V
9| GND| | 0–15A| 0-16V
10| L4| L4 15A| 0–15A| 0-16V
11| GND| | 0–15A| 0-16V
12| GND| | 0–15A| 0-16V
13| L5| L5 15A| 0–15A| 0-16V
14| L6| L6 15A| 0–15A| 0-16V
15| GND| | 0–15A| 0-16V
IGCOM12
12 WAY FUSED OUTPUT MODULE
Provides a constant 12V power to power loads like range hoods, fridges, memory
retentive circuits and other lighting.
IGCOM12 has built in low voltage disconnect and inhibit functions on selected
outputs.
SPECIFICATIONS
PART NO| IGCOM12
NOMINAL VOLTAGE| 12V
MAX INPUT CURRENT| 80A
OUTPUTS| 6 x 30A
6 x 15A
WEIGHT| 780g
WORKING TEMPERATURE| -40°C ~ 65°C
IP RATING| IP20
POWER INPUT TERMINAL DEFINITION
PIN NO| PIN DEFINITION| POLARITY| VOLTAGE RANGE|
RATED CURRENT
---|---|---|---|---
1| BAT+| BAT+| 9–16V| 40A
2| BAT+| BAT+| 9–16V| 40A
3| BAT-| BAT-| |
4| BAT-| BAT-| |
OUTPUT TERMINAL DEFINITION
OUTPUT
C3-1| C3-2A| C3-2B| C3-3A| C3-3B| C3-4
C2-4| C2-2A| C2-1A| OUT4A| OUT3A| OUT1
C2-3| C2-2B| C2-1B| OUT4B| OUT3B| OUT2
PIN DIAGRAM
PIN DIAGRAM
PIN NO| PIN DEFINITION| FUSE| CURRENT RANGE|
VOLTAGE RANGE| FUNCTION| EXAMPLE DEVICE
---|---|---|---|---|---|---
1| C2-1A| F1 30A| 0–15A| 9–16V| Inhibit and LVD| Slide out
2| C2-1B| F1 30A| 0–15A| 9–16V| Inhibit and LVD| Awning
3| C2-2A| F2 30A| 0–15A| 9–16V| Inhibit and LVD| Steps
4| C2-2B| F2 30A| 0–15A| 9–16V| Inhibit and LVD|
5| C2-3| F3 15A| 0–15A| 9–16V| Inhibit and LVD|
6| C2-4| F4 15A| 0–15A| 9–16V| Inhibit and LVD|
7| C3-1| F5 15A| 0–15A| 9–16V| Always On| Outside compressor fridge
8| C3-2A| F6 30A| 0–15A| 9–16V| Always On| Inside compressor fridge
9| C3-2B| F6 30A| 0–15A| 9–16V| Always On|
10| C3-3A| F7 30A| 0–15A| 9–16V| Always On| Range hood
11| C3-3B| F7 30A| 0–15A| 9–16V| Always On|
12| C3-4| F8 15A| 0–15A| 9–16V| Always On|
13| OUT1| F9 15A| 0–15A| 9–16V| Inhibit and LVD| See Note 1 below
14| OUT2| F10 15A| 0–15A| 9–16V| Inhibit and LVD
15| OUT3A| F11 30A| 0–15A| 9–16V| Inhibit and LVD
16| OUT3B| F11 30A| 0–15A| 9–16V| Inhibit and LVD
17| OUT4A| F12 30A| 0–15A| 9–16V| Inhibit and LVD
18| OUT4B| F12 30A| 0–15A| 9–16V| Inhibit and LVD
Note 1: This group can be configured by Dipswitch.
Dip 1 ON: Run Inhibit function & LVD
Dip 2 ON: Always on
Dip 1&2 OFF: Outputs off
The Dipswitch comes default as per the above table and shown right.
IGCOM
INTELLI-GRID CONTROLLER
This is the brains of the INTELLI-Grid system. Controlling communications to
external sensors and devices and shutting down power on non essential loads
when the battery power gets low.
SPECIFICATIONS
PART NO| IGCOM
INPUT| 12V
WORING CURRENT| 80mA
STANDBY CURRENT| 5mA
COMMUNICATION| CAN bus, RS485 Bluetooth
WORKING TEMPERATURE| -25°C ~ 60°C
STORAGE TEMPERATURE| -30°C ~ 85°C
WEIGHT| 200g
IP RATING| IP20
PMTPMS
TYRE PRESSURE MONITORING SYSTEM MODULE
The Tyre Pressure Monitoring System (TPMS) monitors the RVs tyre pressure
before and during the journey.
SPECIFICATIONS
PART NO | PMTPMS x 4 (one for each tyre) |
---|---|
PART NO | Receiver-PMTPMS-R |
INPUT | 6-24V |
WORING CURRENT | 30mA |
WORKING TEMPERATURE | -40°C ~ 85°C |
HUMIDITY | <95% |
RECEIVING FREQUENCY | 433.910Mhz |
WIRED COMMUNICATION | RS485 |
WEIGHT | 150g |
PART NO | Sender * 4 -PMTPMS-S |
WORING VOLTAGE | 2.2 ~ 3.6V |
BATTERY TYPE | CR1632 |
TRANSMITTED CURRENT | <5mA |
TRANSMITTED POWER | <5dbm |
TRANSMITTED FREQUENCY | 433.910Mhz |
PRESSURE RANGE | 14~ 130PSI |
ACCURACY | ± 1.45 PSI |
WORKING TEMPERATURE | -30°C ~ 70°C |
WEIGHT | 13.8g |
PMLVL
LEVELLING SENSOR
Level the RV with the levelling sensor which can be monitored via the phone
app.
Calibration
To calibrate the level sensor, the RV needs to be level in both forward and
back and side to side. Once level, go to the Setting Page, select Level Sensor
and press Calibrate. This will zero the sensor.
SPECIFICATIONS
PART NO| PMLVL
WORKING VOLTAGE| 9~16V
WORING CURRENT| 30mA
WORKING TEMPERATURE| -40°C ~ 85°C
IP RATING| IP20
ACCURACY| ±2°
INSTRUCTIONS ON HOW TO PAIR THE GAS SENSORS
Enable the GAS Feature.
Go to the Setting Page.. Find the Sensors Page and enable it. Paring the
Sensors.
Long press the “SYNC” button on the gas sensor until a value is displayed on
the GAS.
|
Repeat the process to pair second gas sensor.
IGD-BT7
7” COLOUR BLUETOOTH MONITOR
The 7” colour display, enables complete control of the RV or commercial
application. Its smart, intuitive design provides all the vital information at
the press of a button.
SPECIFICATIONS
PART NO| IGD-BT7
WORKING VOLTAGE| 12V
WORKING CURRENT| 350mA Screen ON, 200mA Screen OFF
RESOLUTION| 1024 x 600
COMMUNICATION| RS485.CAN.Bluetooth
WORKING TEMPERATURE| -30°C ~ 70°C
STORAGE TEMPERATURE| -30°C ~ 85°C
WEIGHT| 200g
IP RATING| IP 20
BATTERIES
LB200-HDJ
12V HIGH DISCHARGE 200AH LITHIUM BATTERY
LB200-HD boast impressive capabilities and are ideal for 4WDs and caravans
with high power demands.
SPECIFICATIONS
PART NO| LB200-HD
NOMINAL VOLTAGE| 12.8V
NOMINAL CAPACITY| 200Ah
NOMINAL ENERGY| 2560Wh
CHARGE VOLTAGE| 14.2V
DISCHARGE CUT-OFF VOLTAGE| 11.2V
STANDARD CHARGE CURRENT| 100 Amps
MAXIMUM CHARGE CURRENT| 200 Amps
MAXIMUM DISCHARGE CURRENT| 200 Amps
PEAK DISCHARGE CURRENT| 300 Amps (10Mins)
OPERATING TEMPERATURE| -20°C ~ 60°C
MAXIMUM NUMBER OF BATTERIES IN PARALLEL| 4
NUMBER OF DISCHARGE CYCLES| 3000
WEIGHT| 22KG
IP RATING| IP20
LB400-HDJ
12V HIGH DISCHARGE 400AH LITHIUM BATTERY
The LB400-HD boasts an astonishing 400Ah capacity and a market leading 300A
discharge capability making it ideal to partner with high current drawing
appliances such as 3000W inverters.
SPECIFICATIONS
PART NO| LB400-HD
NOMINAL VOLTAGE| 12.8V
NOMINAL CAPACITY| 400Ah
NOMINAL ENERGY| 5120Wh
CHARGE VOLTAGE| 14.2V
DISCHARGE CUT-OFF VOLTAGE| 11.2V
STANDARD CHARGE CURRENT| 100 Amps
MAXIMUM CHARGE CURRENT| 200 Amps
MAXIMUM DISCHARGE CURRENT| 200 Amps
PEAK DISCHARGE CURRENT| 300 Amps (10Mins)
OPERATING TEMPERATURE| -20°C ~ 60°C
MAXIMUM NUMBER OF BATTERIES IN PARALLEL| 4
NUMBER OF DISCHARGE CYCLES| 3000
WEIGHT| 42.5KG
IP RATING| IP20
PMWSW4
Wireless switches make it easy to install additional switches if required.
i.e. additional bedroom switch is easy as 2 screws for installation.
For programming please contact our customer service.
SPECIFICATIONS
PART NO| PMWSW4
RATED VOLTAGE| 5V
BATTERY TYPE| 2 x CR2032
COMMUNICATION| RF 433Mhz
EFFECTIVE RANGE| Outdoor 30m, Indoor 15m
IP RATING| IP20
WORKING TEMPERATURE| -20°C ~ 60°C
MOUNTING| Surface
WEIGHT| 40g
WATER TANK PROBE
For Intelli-Grid system, a maximum of 4 probes can be monitored.
Note: Always check the probe required for the water tank before pruchase.
There are 2 probe styles. PMWS200
- Side installation
- Suitable for water tank
- Depth >200mm
PMWS400
- Side installation
- Suitable for water tank
- Depth <400mm
STRUCTURE AND INSTALLATION
Monitor
Inverter
Note: Please install the inverter in a well ventilated area so that it works at maximum efficiency.
Water Probe
PMWS400 WATER TANK PROBE PMWS200 WATER TANK PROBE
INTELLI-GRID-BT7
WARRANTY STATEMENT
Applicable only to product sold in Australia
Brown & Watson International Pty Ltd of 1500 Ferntree Gully Road, Knoxfield,
Vic., telephone (03) 9730 6000, fax (03) 9730 6050, warrants that all products
described in its current catalogue (save and except for all bulbs and lenses
whether made of glass or some other substance) will under normal use and
service be free of failures in material and workmanship for a period of two
(2) years (unless this period has been extended as indicated elsewhere) from
the date of the original purchase by the consumer as marked on the invoice.
This warranty does not cover ordinary wear and tear, abuse, alteration of
products or damage caused by the consumer. Projecta solar panels are covered
by a 1 year warranty for materials and workmanship and a 20 year warranty for
at least 80% power output.
To make a warranty claim the consumer must deliver the product at their cost
to the original place of purchase or to any other place which may be nominated
by either BWI or the retailer from where the product was bought in order that
a warranty assessment may be performed. The consumer must also deliver the
original invoice evidencing the date and place of purchase together with an
explanation in writing as to the nature of the claim.
In the event that the claim is determined to be for a minor failure of the
product then BWI reserves the right to repair or replace it at its discretion.
In the event that a major failure is determined the consumer will be entitled
to a replacement or a refund as well as compensation for any other reasonably
foreseeable loss or damage.
This warranty is in addition to any other rights or remedies that the consumer
may have under State or Federal legislation.
IMPORTANT NOTE
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and compensation for any other reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a major failure.
Distributed by
AUSTRALIA
Brown & Watson International Pty. Ltd.
Knoxfield Victoria 3180
Phone: (03) 9730 6000
Fax: (03) 9730 6050
National Toll Free: 1800 113 443
NEW ZEALAND OFFICE
Griffiths Equipment Ltd.
19 Bell Avenue,
Mount Wellington,
Auckland 1060, New Zealand
Phone: (09) 525 4575 IS537
Issue 1: 17/03/2023
Documents / Resources
|
PROJECTA IG2-BT7 High Powered Management with Bluetooth
Monitor
[pdf] Instruction Manual
IG2-BT7 High Powered Management with Bluetooth Monitor, IG2-BT7, High Powered
Management with Bluetooth Monitor, Powered Management with Bluetooth Monitor,
Management with Bluetooth Monitor, Bluetooth Monitor, Monitor
---|---