PROJECTA INVCHRD-BT Inverter Charger Battery Monitor Instruction Manual

June 12, 2024
Projecta

PROJECTA LOGO INVERTER CHARGER BATTERY MONITORPROJECTA INVCHRD BT Inverter
Charger Battery Monitor P/No INVCHRD-BT

WARNINGS – IMPORTANT PLEASE READ

  • Do not disassemble the monitor. Take to a qualified person if the unit requires repairing.

PRODUCT OVERVIEW

PROJECTA INVCHRD BT Inverter Charger Battery Monitor -
OVERVIEW

NO DEFINITION DESCRIPTION
1 Solar To indicate solar charger is charging
2 Invert To indicate inverters is working
3 Bypass To indicate Grid or generator is presenting
4 Charge To indicate battery is charging
5 Overload alarm To indicate when inverter is overloaded
6 Battery low voltage alarm To indicate when inverter reach under-voltage
7 Over temperature alarm To indicate when inverter is over-temperature
8 Load percentage To indicate the percentage of actual load power against

rated power of inverter installed
9| Inverter ON/OFF switch| To turn Inverter ON or OFF
10| Scroll up / Back| LCD displaying value
11| LCD screen|
12| Scroll down / confirm button| To scroll down to next item. Or as function of confirmation of your selection and configuration. With long press for 3 secs.
13| Mute button| To mute or unmute the alarm
14| Battery SOC| To indicate battery state of charge

DISPLAY INFORMATION IN VALUE INFORMATION AREA

V Battery Voltage
A Battery Current
I Battery SOC

FEATURES

  • Device allows users to remotely monitor and control Projecta Inverter Chargers

  • Displays battery voltage, current, inverter load percentage, AC input/output voltage, frequency and power

  • Battery status can be monitored via smart phone or tablet if connected.

  • Inbuilt intelligent battery monitoring technology

  • Will show battery information where a Projecta HD sereies battery is connected to the system.

INSTALLATION

Step 1: Cut holes on mounting surface following the cut-out dimension of solid line area in the below diagram
Step 2: Place the INVCHRD-BT in position properly and fix the INVCHRD-BT by 4pcs M3*12 screws

PROJECTA INVCHRD BT Inverter Charger Battery Monitor -
INSTALLATION

CONNECTION

  • Use the cable with RJ45 terminal to connect the INVCHRD-BT to the ComMON terminal of the inverter charger  in Fig.1.
  • Use the cable with RJ45 terminal to connect the INVCHRD-BT to the ComMON terminal of the inverter charger and connect the ComSync or ComSyncIn terminal of the inverter charger to the CAN/RS485 terminal of the HD Series lithium battery in Fig.2.

PROJECTA INVCHRD BT Inverter Charger Battery Monitor -
CONNECTION

APP
INVCHRD-BT Support APP can be downloaded on the Google Play Store for Android Devices and the AppStore for Apple Devices.
DETAIL LED DISPLAY INFORMATION OF BATTERY SOC

Battery Status| SOC| LED 1| LED 2| LED 3| LED 4| LED 5
---|---|---|---|---|---|---
Charging| SOC=100%| Illuminate| Illuminate| Illuminate| Illuminate| Illuminate
80%≤SOC < 100%| Illuminate| Illuminate| Illuminate| Illuminate| Flash
60%≤SOC < 80%| Illuminate| Illuminate| Illuminate| Flash| Off
40%≤SOC < 60%| Illuminate| Illuminate| Flash| Off| Off
20%≤SOC < 40%| Illuminate| Flash| Off| Off| Off
0%≤SOC < 20%| Flash| Off| Off| Off| Off
Discharge| 80%≤SOC ≤ 100%| Illuminate| Illuminate| Illuminate| Illuminate| Illuminate
60%≤SOC < 80%| Illuminate| Illuminate| Illuminate| Illuminate| Off
40%≤SOC < 60%| Illuminate| Illuminate| Illuminate| Off| Off
20%≤SOC < 40%| Illuminate| Illuminate| Off| Off| Off
0%≤SOC < 20%| Illuminate| Off| Off| Off| Off
SOC=0| Off| Off| Off| Off| Off

DISPLAY INFORMATION VALUE AREA

Display Information Item
Battery V
A Battery current
AC Output kW
Hz AC output frequency
V AC output voltage
A AC output current
AC Input kW
Hz AC Input frequency
V AC Input voltage
A AC Input current
Solar kW
V PV voltage

Note: Solar is for the INVCHR3-48V with built in MPPT

CONFIGURATION ITEMS AND SETTING VALUES

Display Information Configuration Item Default Setting and Setting Step
Battery V Absorption Voltage, ON
V Float Voltage, Flashing Step: 0.1V, Default: 13.6V
A Max Charge Current Step: 1A, Default: 30A
AC Output V Output Voltage
Hz Output Frequency Default: 50/60Hz
AC Input A AC Input Rating
Buzzer Alarms Buzzer ON or OFF
Enable SOC Display SOC lights and battery background lights are all flash

ON: Enable SOC display
OFF: Disable SOC display
Default: ON
Enable Screen Off Function| Power lights and battery back-ground lights are all flash| ON: Enable the Screen Off Function
OFF: Disable the Screen Off Function
Default: OFF

NOTE: Once the Screen Off function is enabled, the screen will automatically go off if there is no key operation for three minutes. If the inverter status changes or an alarm occurs, it will be restarted keep the screen on for three minutes.

CONFIGURATION

Step 1. To enter into the configuration: Press scroll down/confirm button for 2 seconds.

PROJECTA INVCHRD BT Inverter Charger Battery Monitor - CONFIGURATION
1

Step 2. Then you can use scroll up or scroll down button to choose the parameter you want to change.

PROJECTA INVCHRD BT Inverter Charger Battery Monitor - CONFIGURATION
2

Step 3. Long press the scroll down/confirm button for 2 seconds to trigger on the configuration, the number/icon will flash.

PROJECTA INVCHRD BT Inverter Charger Battery Monitor - CONFIGURATION
3

Step 4. Use scroll up or scroll down button to change the value.

PROJECTA INVCHRD BT Inverter Charger Battery Monitor - CONFIGURATION
4

Step 5. Afterwards, long press the scroll down/ confirm button for 2 seconds to confirm the configuration. The two bars (load ratio and battery soc) will flash indicating the configuration is in process.

PROJECTA INVCHRD BT Inverter Charger Battery Monitor - CONFIGURATION
5

Step 6. After you have done all configuration you need, please press scroll up/return button for 2 seconds to exist configuration.

PROJECTA INVCHRD BT Inverter Charger Battery Monitor - CONFIGURATION
6

ERROR CODES

The INVCHRD-BT to Projecta’s Inverter Chargers
INVERTER ERROR CODES

CODE DISPLAY DESCRIPTION
101 U_Bus_OV Battery Over-Voltage
102 U_Bus_LV Battery Under-Voltage
103 U_Bus_HW_Pro DC Bus Hardware Under-Voltage
104 PSU_Fault Auxiliary Power Error
105 T_HS_OT Heat Sink Over-Temperature
106 T_TX_OT Transformer Over-Temperature
107 Sam_HD_Fault Sampling Fault
108 EEPROM_Fail EEPROM Fault
109 Output_ShortCut Output Short Circuit
110 Output_OverLoad Output Over-Load
111 CoolSys_Err Fan Error
112 U_BAT_Low_Deep Battery Deep Discharge
113 U_INV_LV Inverter Output Under-Voltage
114 Instant_OC_Soft Inverter Output Instant
115 EPO Emergency Stop
116 Rly_Err Relay Error

MPPT CHARGER CONTROLLER ERROR CODES

CODE DISPLAY DESCRIPTION
301 U_Bus_OV DC Bus Over-Voltage
303 U_Bus_OV HD Battery Over-Voltage(Hardware)
304 Buck_ShortCut Buck Short Circuit
305 I_Buck1_OC Buck1 Over-Current
306 I_Buck2_OC Buck2 Over-Current
307 T_Board_OT Control Board Over-Temperature
308 T_HS_OT Heat Sink Over-Temperature
309 PSU_LV Auxiliary Power Under-Voltage
310 PSU_LV_HD Auxiliary Power Under-Voltage(Hardware)
311 Sam_HD_Fault Sampling Fault
312 EEPROM_Fail EEPROM Fault

Note: Solar is for the INVCHR3-48V with built in MPPT
BMS ERROR CODES

CODE DISPLAY DESCRIPTION
ERR400 Module_OV Lithium battery is over voltage protection
ERR401 Module_UV Lithium battery is under voltage protection
ERR402 Module_OT Lithium battery’s temperature is too high
ERR403 Module_UT Lithium battery’s temperature is too low
ERR404 Discharge_OC Lithium battery’s discharge current is over current.
ERR405 Charge_OC Lithium battery’s charge current is over current.
ERR406 Module_INT_Err Lithium battery module fault

WARNING CODES

INVERTER WARNING CODES

CODE DISPLAY DESCRIPTION
1 U_BAT_OV Battey Over-Voltage Warning
2 U_BAT_LV Battery Under-Voltage
3 U_BAT_LV_Fault Battery Under-Voltage Protection
4 OverLoad Over-Load
5 NTC_HS_Fault Heat sink NTC Failed
6 NTC_TZ_Fault Transformer NTC Failed
7 T_BAT_OT Battery Over-Temperature
8 Fan_Fault Fan Error
9 ParConnect_Err Parallel Connection Error
10 ParComm_Err Parallel CAN Communication Error
11 Par_ID_Conflict Parallel ID Conflict
12 Par_ParaSet_Conflict Parallel Parameter Setting Conflict
13 Par_SyncTimeOut_Err Parallel Synchronization Timeout
14 ModeSet_Mismatch Working Mode Setting Mismatched
15 Par_OutputCircuit_Err Parallel Output Circuit Error
20 ACin_OV AC Input Over-Voltage
22 ACin_OF AC Input Over-Frequency
23 ACin_LF AC Input Under-Frequency
24 ACin_PhaseErr AC Input Phase Error
25 U_Neu_2_GND_Err AC Input Voltage Between Neutral and Ground Error

MPPT CHARGER CONTROLLER WARNING CODES

CODE DISPLAY DESCRIPTION
203 CUR_Limit MPPT Current Limit Warning
205 NTC_HS_Fault Heat Sink NTC Failed
207 Fan_Fault Fan Error

Note: Solar is for the INVCHR3-48V with built in MPPT
BMS WARNING CODES

CODE DISPLAY DESCRIPTION
50 Module_HV Lithium battery is over voltage
51 Module_LV Lithium battery is under voltage
52 Module_HT Lithium battery’s temperature is too high
53 Module_LT Lithium battery’s temperature is too low
54 Discharge_HC Lithium battery’s over current discharge.
55 Charge_HC Lithium battery’s charge current too high.
56 INT_Comm Fail Communication error with lithium batteries.
57 EXT_Comm Fail Communication error with inverter charger.
58 SOC_Low Lithium battery’s SOC is too low

SPECIFICATIONS

DISPLAY DESCRIPTION
Input Voltage 6.5~16Vdc
Communication RS485
Cable Length 5 metres
IP Rating IP20
Working Temperature -20~65°C
Suits Inverters INVCHR2, INVCHR3 & INVCHR3-48V
Suits Batteries in system LB100-HD, LB200HD, LB400-HD, LB50-48VHD, LB100-48HD

WARRANTY STATEMENT

Applicable only to product sold in Australia
Brown & Watson International Pty Ltd of 1500 Ferntree Gully Road, Knoxfield, Vic., telephone (03) 9730 6000, fax (03) 9730 6050, warrants that all products described in its current catalogue (save and except for all bulbs and lenses whether made of glass or some other substance) will under normal use and service be free of failures in material and workmanship for a period of two (2) year (unless this period has been extended as indicated elsewhere) from the date of the original purchase by the consumer as marked on the invoice. This warranty does not cover ordinary wear and tear, abuse, alteration of products or damage caused by the consumer.
To make a warranty claim the consumer must deliver the product at their cost to the original place of purchase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a warranty assessment may be performed. The consumer must also deliver the original invoice evidencing the date and place of purchase together with an explanation in writing as to the nature of the claim.
In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or replace it at its discretion. In the event that a major failure is determined the consumer will be entitled to a replacement or a refund as well as compensation for any other reasonably foreseeable loss or damage.
This warranty is in addition to any other rights or remedies that the consumer may have under State or Federal legislation.
IMPORTANT NOTE
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Distributed by
AUSTRALIA
Brown & Watson International Pty. Ltd.
Knoxfield Victoria 3180
Phone: (03) 9730 6000
Fax: (03) 9730 6050
National Toll Free: 1800 113 443
NEW ZEALAND OFFICE
Griffiths Equipment Ltd.
19 Bell Avenue,
Mount Wellington,
Auckland 1060, New Zealand
Phone: (09) 525 4575 Fax: (09) 579 1192
IS515
Issue 1: 16/11/2022