PROJECTA INVCHR2 Intelli-Grid 12v Inverter Charger User Guide
- June 12, 2024
- Projecta
Table of Contents
PROJECTA INVCHR2 Intelli-Grid 12v Inverter Charger
Product Information
The INTELLI-GRID 12V Inverter Charger, with model numbers INVCHR2 and INVCHR3, is a versatile device that combines the functions of an inverter and a battery charger. It is designed to provide reliable power backup and charging capabilities for various applications.
General Safety Instructions
Before using the Inverter Charger, please read and follow the safety instructions provided in the user manual to ensure safe and proper operation.
Structure
The Inverter Charger features a compact and sturdy design with the following components:
- Front: The front panel of the device includes LED indicators that provide information about its different functions.
- Control Panel: Located on the front panel, the control panel allows users to adjust settings and monitor the device’s operation.
- Remote Control and Monitor: A remote control and monitor unit (MCK) is included for convenient operation from a distance.
- Connection Compartment: The connection compartment houses various terminals and ports for connectivity.
- Signal Terminal: The signal terminal provides connections for battery monitoring, remote control, external monitoring, communication with lithium batteries, and output control.
Product Usage Instructions
Safety Precautions
- Before using the Inverter Charger, please read and follow the safety instructions provided in the user manual to ensure safe operation and prevent any potential hazards.
Installation
Follow the steps below to install the Inverter Charger:
- Choose a suitable location for installation, considering factors such as ventilation, accessibility, and mounting options.
- Ensure that the input power source and batteries are properly connected to the Inverter Charger according to the provided guidelines.
- Connect any external monitoring devices or remote control units if required, using the appropriate ports and terminals.
- Securely mount the Inverter Charger in the chosen location using the provided mounting hardware.
- Double-check all connections and ensure that they are secure and properly insulated.
Operation
Once the Inverter Charger is installed, follow these instructions to operate it:
Inverter Mode
To use the Inverter Charger in inverter mode:
- Ensure that the input power source is disconnected or turned off.
- Turn on the Inverter Charger using the control panel or the remote control unit.
- The “Invert” LED indicator will illuminate, indicating that the unit is inverting and providing power from the battery.
- Connect your desired AC load to the output of the Inverter Charger.
- Monitor the operation and adjust settings as needed using the control panel or remote control.
Grid Boost Mode
To use the Grid Boost feature of the Inverter Charger:
- Ensure that both the input power source (grid mains or generator) and the battery are connected to the Inverter Charger.
- Turn on the Inverter Charger using the control panel or remote control unit.
- The “AC In” LED indicator will flash, indicating that the unit is detecting input power.
- The Inverter Charger will automatically boost the power from the input source using the battery power, providing additional power capacity.
- Connect your desired AC load to the output of the Inverter Charger.
- Monitor the operation and adjust settings as needed using the control panel or remote control.
Battery Charging
To use the Inverter Charger for battery charging:
- Ensure that the input power source (grid mains or generator) is connected to the Inverter Charger.
- Turn on the Inverter Charger using the control panel or remotecontrol unit.
- The “Charge” LED indicator will illuminate, indicating that the unit is in bulk or absorption charging mode.
- Connect the lead acid battery to the designated terminals,following the provided guidelines.
- The built-in charger will automatically initiate the charging process, following a multi-stage sophisticated charging algorithm.
- Monitor the charging progress and adjust settings as needed using the control panel or remote control.
For detailed instructions on specific features, settings, and troubleshooting, please refer to the user manual provided with the Inverter Charger.
WARNING
- • High Voltages inside
- The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capability, or lack of experience and knowledge, unless they have been given supervision of instruction.
- Children being supervised not to play with the appliance.
- This device can only charge 12V batteries:-
- INVCHR2 can charge
- 12V Lead acid batteries from 100~2400Ah
- 12V Lithium batteries from 100~1200Ah
- INVCHR3 can charge
- 12V Lead acid batteries from 100~3600Ah
- 12V Lithium batteries from 100~1800Ah
- When charging Lead Acid batteries or vented batteries, the batteries must be placed in well-ventilated area when charging.
CAUTION: THE DC FUSE MUST HAVE BEEN TURNED OFF BEFORE SERVICING.
General Safety Instruction
Safety instruction
As dangerous voltages and high temperature exist within the Inverter Charger, only qualified and authorized maintenance personnel are permitted to open and repair it. Please make sure Inverter Charger is turned off before opening and repairing it.
This manual contains information concerning the installation and operation of
the Inverter Charger.
All relevant parts of the manual should be read prior to commencing the
installation.
Please follow all local laws and regulations. Any mis-use of the product
according to the manual will not be covered by warranty.
General precaution
- DO NOT expose to dust, rain, snow or liquids of any type, the inverter is designed for indoor use. DO NOT block off ventilation, otherwise the Inverter Charger could overheat.
- To avoid fire and electric shock, make sure all cables selected are the right gauge and all connections are tight. Smaller diameter and damaged cables are dangerous and could risk fire.
- Please do not put any flammable goods near to inverter.
- NEVER place unit directly above lead acid batteries, gases from a battery will corrode and damage Inverter Charger.
- DO NOT place battery on top of Inverter Charger.
Precaution regarding battery operation
- If battery acid makes contact with your skin use plenty of water wash the acid off. If acid goes on your clothes remove these clothes. If irritation to the skin occurs see medical advice.
- Lead Acid batteries may generate flammable gas during charging. NEVER smoke or allow a spark or flame in vicinity of battery.
- DO NOT place metal tools on the battery, a spark may occur and a short circuit might lead to explosion.
- REMOVE all personal metal items such as rings, bracelets, necklaces, and watches while working with batteries. Batteries can cause short-circuit current high enough to make metal melt, and could cause severe burns.
Instruction
Brief Instruction
General Description
- INVCHR2 and INVCHR3 are 2-in-1 inverter chargers designed for high power management applications such as RV, utility vehicles, marine and emergency.
- With the rapid charging capability of Projecta’s lithium batteries, the Inverter Chargers can provide high current charging from a mains source and are capable of starting and powering the most demanding appliances, such as air conditioning, water pumps, washing machine, freezer, compressor, power tools and induction cooktops.
- The inverter charger is fitted with an AC transfer switch which manages the AC power automatically switching between mains power and inverter power.
- With their Grid Boost feature, INVCHR2 and INVCHR3 can work with a limited AC source such as a generator or restricted AC mains to provide an additional boost using DC power.
Structure
Front
Control panel
Table 2-1 LED directive funtion
LED | Function |
---|---|
Invert | It will illuminate when unit is inverting. |
AC In | It will flash when unit detect any input, mains or generator. |
Charge
| It will flash when unit is in float charging.
It will illuminate when unit is in bulk or absorption charging.
Warning| It will flash when unit has warning.
Fault| It will flash when unit has error.
Bluetooth LCD monitor (P/No. INVCHR-BT)
Allows users to remotely monitor and control Projecta Inverter Chargers. Displays battery voltage, current, inverter load percentage, AC input/output voltage, frequency and power. Battery status can also be monitored via smart phone or tablet if connected with Bluetooth.
- Remotely switch on/off inverter.
- Will show battery information when a Projecta HD series lithium battery is connected to the system.
- The APP can be downloaded from the APP store or Google play under PROJECTA Inverter Charger (INVCHR2/3)
Connection compartment
Table 2-2 Signal terminal introduction
No. | Silk-screen | Definition |
---|---|---|
1 | Bat Sample | Battery temperature and voltage sample. |
2 | Remote | A dry contact input for remote on/off |
3 | Com MON | RS485 port for external monitor such as INVCHR-BT |
4 | Com Sync | Communication with Projecta’s HD series lithium batteries for |
advanced monitoring
5| Relay1 (NO,C.NC)| Dry contact output control 1(NO,C,NC)
6| Relay2 (NO,C.NC)| Dry contact output control 2(NO,C,NC)
7| S+| Slave Charger for Starter Battery
Dimension
Inverter Charger Functions
Grid Boost is a useful feature when limited grid supply is available or working with a generator. The Inverter Charger will disconnect the mains AC power providing power from the inverter and battery or boost this power using AC mains and the inverter / battery power. With this feature, you can avoid tripping a shore power circuit breaker or reduce generator capacity by up to 50%.
Powerful and Reliable Inverter
High performance pure sine wave
- INVCHR2 and INVCHR3 are pure sine wave inverters generating a near perfect waveform.
High surge power capability
- Providing outstanding surge power capabilities you can easily run heavy inductive loads like fridges, coffee makers, microwaves, power tools, air conditioning and induction cooktops.
Battery low voltage protect
- Inverter Charger provides configurable battery low voltage protection.
Professional Battery Charger for lead acid battery
- Multi stage sophisticated charging algorithm for lead acid battery
Fitted with multistage charging algorithm (bulk-absorption-float-recycle), the built-in charger of Inverter Charger is designed to charge the battery quickly. Microprocessor controlled charging algorithm with variable absorption charging timer will guarantee optimal charging for batteries of different discharged state.
Float charging and recycle charging program guarantee your battery is getting proper maintenance in case of long standby periods providing less aging.
Battery Sample Cable (Temperature and voltage)
Battery temperature is a key factor in correct charging for lead acid batteries. The charging formula must be adjusted (automatically and in real time) according to the actual battery temperature to ensure that the battery is fully charged but not overcharged or undercharged. All charging voltages recommended by battery manufacture are in fact ONLY applied at 20°C-25°C and the temperature probe ensures optimal charging..
The Bat sample cable (battery temperature and voltage sensor) supplied with Inverter Charger measures the temperature of battery and automatically makes adjustments at real time to properly charge your batteries at compensation rate of – 4mV/°C/cell. In case of Bat sample cable is not present, Inverter Charger will use 25°C as default setting. This feature is especially recommended for sealed batteries and/or when important fluctuations of battery temperature are expected.
Different battery chemistries
Inverter Charger offers premium charging algorithm for commonly encountered lead acid battery chemicals include AGM, GEL, Wet, lead-carbon and Lithium battery, of which you can set through the LCD/LED interface.
Lithium Battery Compatible
Projecta Inverter Chargers support universal LFP charging profile and offered pre-defined LFP charging profile for Projecta HD series lithium batteries.
Built in BMS pre-defined LFP charging and communication for LBXXX-HD series batteries
According to cell temperature and real time SOC, BMS will send commands to
battery charger asking for optimum charging voltage and current. This
synchronization will prevent overheating or overcharging especially at the end
of charging, to extend the life of the battery.
Instead of using voltage as protection, SOC value is used to avoid permanently
damaging of lithium batteries due to being left discharged for long time.
AC Transfer Switch
In case of poor AC mains power (due to poor voltage/ frequency or waveform characteristic, the Inverter Charger will switch to inverter and battery power. In case of AC mains failure or exceeding the maximum AC input current set by the user, the Inverter Charger will initiate a quick switch to inverter, which will guarantee continuous power. When stable AC power is resumed, the inverter charger will switch back to AC mains power after a 5 second delay. Due to its ultra quick transfer design, as quick as 0ms. The Inverter Charger could be used as a UPS.
Ground Relay
The neutral output of Inverter Charger is automatically connected to earth upon no external AC sources are available. Once external AC sources present, the ground relay will open. The Ground relay is required for the RCD to function correctly.
Protections and Safeguards
The Inverter Charger is equipped with a series of complete hardware and software protection functions to ensure its stable and reliable operation.
Overload protection
When overload protection is trigger on, it will restart automatically after 60s. And after three consecutive overload shutdown protections, the equipment will not restart automatically. At this time, the user needs to manually restart.
Over temperature protection
When the internal temperature is too high, Inverter Charger will enter into the over-temperature protection. After the internal temperature returns to normal, it can automatically resume normal operation.
Short circuit protection
- The equipment will automatically shut down when the AC output is shorted and needs to be manually activated.
Battery over temperature protection
- During charging, the equipment will continuously monitor the battery temperature. When the battery temperature is too high, the equipment will automatically reduce the charging current.
- When the battery is hot the charger will automatically turn off to protect the battery.
Battery low voltage protection
- To prevent the permanent damage caused by the over discharge of battery, the equipment will automatically cut off the output according to the low voltage protection point set by the user.
RCD (RCBO)
- The Inverter Charger is fitted with an RCD (Safety Switch) to ensure maximum protection for our customers.
- The RCD is also fitted with an over current feature to protect wiring. If the RCD trips it will need to be manually reset.
Communication
Dry contact input
- Inverter Charger is equipped with a dry contact input for remote on/off,
Dry contact output
Inverter Charger is equipped with two NO/NC relay type dry contact output. The following is the default setting:
- Relay1: The relay is closed when the battery is under voltage.
- Relay2: The relay is closed when a fault or overload occurs.
RS485
Equipped with a RS485 interface.
Installation and Wiring
Warning: Keep away from fire, avoid direct sunlight and rain; do not store near flammable, explosive or corrosive gases or liquids. Don’t install in a working environment where metal dust can get into the inverter charger.
- Please install the equipment in a location of dry, clean, cool with good ventilation.
- Operating temperature: -20~65°C
- Storage temperature: -40~70°C
- Cooling: Force fan
- Relative humidity in operation: 95% without condensation.
Operation
Check before Operation
Please check before Operation according to the following.
- Inverter is installed correctly and steady.
- Reasonable cable layout to meet customer requirements.
- Make sure the grounding is reliable.
- Make sure the ground wire is properly connected, firm and reliable.
- Double check the battery breaker is OFF.
- Make sure the cables are properly connected, firm and reliable.
- Ensure there is plenty of space around the inverter charger and the area is clean and tidy.
Power ON Test
- Make sure the battery voltage is within the permissible range before turning ON the breaker.
Note: there are three ways the inverter / charger can work
- Default (test mode)
- Fitted with Remote P/n: INVCHRD-BT.
- Without remote or INTELLI-Grid connected.
Default Test Mode
Please follow the following instruction step by step.
- Step 1: Turn on the circuit breaker between the battery and the inverter.
- Step 2: Press the On/Off button to turn on the inverter entering into self diagnostic.
- Step 3: Press the On/Off button again to turn on the inverter.
- Step 4: Observe the LED light to make sure the inverter is running normally. (refer toTable 2-2 LED directive function)
Power OFF
After the inverter power is turned OFF, there is still residual power and heat in the chassis, which may lead to electric shock.
- Method 1: Press the On/Off button about 2secs to turn off the output of inverter. Afterwards, you can press and hold the On/Off for 5secs, after hearing consecutive beep, you can permanently shut down the inverter.
- Method 2: Press and hold the On/Off for 5secs, after hearing consecutive beep, you can permanently shut down the inverter straight away.
Remote connected (P/n: INVCHRD-BT)
- STEP 1: Turn on the circuit breaker between the battery and inverter.
- STEP 2: Turn on the switch on the Remote (P/n: INVCHRD-BT). The inverter should now be working.
- STEP 3: Turn the switch off to turn the inverter off.
Inverter Charger Previously used with Remote or INTELLI-Grid system with no remote connected
- STEP 1: Wire in with a latching switch to the remote connections inside the wiring compartment.
- STEP 2: Turn on the switch, this will turn the inverter on.
- STEP 3: Turn the switch off to turn the inverter off.
Configuration
Settings may only be changed by a qualified person. Read the instructions thoroughly before implementing changes. During setting of the charger, the AC input must be removed.
Default Setting
System | Rate AC Voltage | 230VAC |
---|---|---|
Rate AC Frequency | 50Hz |
Battery
| Battery Type| AGM
Battery AGH| 200AH
Max Charge Current| 100% of the Max charge current
Absorption Voltage| 14.4
Float Voltage| 13.5
Undervoltage Protect Recover| 13.0
Undervoltage Warning| 11
Undervoltage Protect| 10.5
Deep Undervoltage Protect| 9.9
AC Input| Power Assist Cur| 16
---|---|---
Model | INVCHR2 | INVCHR3 |
---|---|---|
Power Assist | YES | |
AC input | Input Voltage Range: 175~265 VAC, Input Frequency: 45~65Hz | |
AC input Current | 32A (transfer switch) |
Inverter
Nominal battery voltage| 12VDC
Input voltage range| 10.5~17VDC
Output| Voltage: 220/230/240 VAC ± 2%, Frequency: 50/60 Hz ± 0.1%
Harmonic distortion| <2%|
Power factor| 1.0|
Cont. output power 25°C| 2000W| 3000W
Output power (30min) at 25°C| 2150W| 3200W
Peak Power| 4000W| 6000W
Cont. output power at 40°C| 1800W| 2700W
Maximum efficiency| 93%
Zero load power| 12W| 16W
RCD safety switch| 16A/30mA
Charger
Charge voltage “absorption”| 14.4VDC
Charge voltage “float”| 13.8VDC
Battery types| AGM / GEL / OPZV / Lead-Carbon / Li-ion / Flooded
Battery charge current| 120A| 180A
Temperature compensation| YES
Slave charger| 3A
General Data
AC Output Current| 32A (Limited by the 16Amp RCD 16A)
Transfer time| <2ms(<15ms when WeakGrid Mode)
Remote on-off| Yes
Programmable relay| 2x
Protection| a) output short circuit, b) overload, c) battery voltage over
voltage
d) battery voltage under voltage, e)over temperature, f) Fan block
g) input voltage out of range, h) input voltage ripple too high
General purpose com. Port| RS485
Operating Temperature range| -20 to +65˚C
Storage temperature range| -40 to +70˚C
Relative humidity in operation| 95% without condensation
Altitude| 2000m
Mechanica Data
Dimensions| 513x275x145mm
Net Weight| 18.3kg| 21kg
Cooling| Forced fan
Protection Index| IP20
Standards
Electrical Safety Certified| Yes
EMC| EN61000-6-1,EN61000-6-2,EN61000-6-3, EN61000-3-11,EN61000-3-12
WARRANTY STATEMENT
Brown & Watson International Pty Ltd (“BWI”) of 1500 Ferntree Gully Road, Knoxfield, Vic., telephone (03) 9730 6000, fax (03) 9730 6050, warrants that all products described in its current catalogue will under normal use and service be free of failures in material and workmanship for a period of three (3) years from the date of the original purchase by the customer as marked on the invoice. This warranty does not cover ordinary wear and tear, abuse, alteration of products or damage caused by the purchaser.
To make a warranty claim the consumer must deliver the product at their cost to the original place of purchase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that the warranty assessment may be performed. The consumer must also deliver the original invoiceevidencing the date and place of purchase together with an explanation in writing as to the nature of the claim.
In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or replace it at its discretion. In the event that a major failure is determined the consumer will be entitled to a replacement or a refund as well as compensation for any other reasonably foreseeable loss or damage. This warranty is in addition to any other rights or remedies that the consumer may have under State or Federal legislation.
IMPORTANT NOTE
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Contact
Distributed by
- AUSTRALIA
Brown & Watson International Pty. Ltd.
- Knoxfield Victoria 3180
- Phone: (03) 9730 6000
- Fax: (03) 9730 6050
National Toll Free: 1800 113 443
NEW ZEALAND OFFICE
Griffiths Equipment Ltd
- 19 Bell Avenue, Mount Wellington, Auckland 1060, New Zealand
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>