Syvecs LTD R35GTR AWD Controller Owner’s Manual
- June 9, 2024
- Syvecs LTD
Table of Contents
Syvecs LTD R35GTR AWD Controller Owner’s Manual
Contents
1 x Syvecs AWD ECU
1 x USB Cable
1 x BurnOut Switch (Optional)
1 x 20k Rotary Potentiometer (Optional
Installation
First you need to locate the 4WD Ecu on the R35GTR, this is found on the right hand side on the Vehicle under the appropriate seat – LHD Drive cars this is passenger seat, RHD drive cars this is the driver’s seat.
Removing the seat is done by unclipping the 4 plastic bolt covers in each
corner of the seat and then using a 14mm socket turning the bolts
anticlockwise.
Carefully then tilt the seat backwards and unplug the 3 electrical connection.
After this remove the seat from the vehicle.
Next step is to lift the carpet which was below the seat and remove the polystyrene cover.
The 4WD Ecu will then become present as shown below.
Unplug the connector going into the ecu and then plug into the female connector housing onto the Syvecs 4WD Controller. Reverse the steps now for removing the seat and following the controls below for using the product.
Controls
RWD Drive Mode / BurnOut
There is 2 ways to activate the burnout mode on the R35GTR AWD Controller V2
-
First is via activating Snow Mode / Save Mode which is shown here This will bring on a 4wd light on the dash to illustrate that RWD Drive mode is active. To switch it back to AWD just turn of Snow Mode / Save Mode
-
Second Option is via wiring in a Burnout Switch to AN01 Input on the Syvecs Awd controller (Pin 21). AN01 has a internal 5v pull-up set so the input will sit at 5v, the other side of the Switch needs to be connected to Ground on the chassis or via Ground Pins 1, 2, 25, 26 on the Syvecs AWD Controller.
AN01, AN02, 5V and Ground are available on the External 4 way DTM connector. When AN01 is less than 3v it will activate 2WD Mode / Burnout Mode. -
Optional Burnout Mode options are available in the software from Hazard Switch and Handbrake.
Live Adjustment Potentiometer
Users can have the ability to adjust the AWD Duty live via a laptop or with a
external
potentiometer with the Syvecs AWD Unit. A 20K Rotary Potentiometer can be
wired to the AN2 input of the Syvecs Controller and it will apply a multiplier
to the Duty. Wiring for the Pot is here — >
0 -1 = No Adjustment (Logic Off)
1 -2 = 0.6 Multiplier (Less Duty)
2 -3 = 0.7 Multiplier
3 -4 = 0.8 Multiplier
4 -5 = 0.9 Multiplier
5 -6 = 1.0 Multiplier (No Adjustment)
6 -7 = 1.1 Multiplier
7 -8 = 1.2 Multiplier
8 -9 = 1.3 Multiplier
9-10 = 1.4 Multiplier (More Duty)
MagnetoResistive ABS Sensor Support
The Syvecs R35 AWD Controller supports magneto-resistive wheels speed sensors
which the factory car use. These can be connected direct to the Syvecs
AWDcontroller via Pins 9 to 12. When doing this another version of code can be
loaded into the controller via USB to allow the speed data collected from the
sensor to be transmitted on the OEM ABS Can Frames or as Bosch M4 ABS Frames.
This means users can remove the OEM ABS Computer from the car if wanted.
Connect as shown below.
Syvecs AWD 26 Way Pin | Function | Nissan E41 ABS Connector Pin |
---|---|---|
9 | FL Speed Signal | 45 |
10 | Fr Speed Signal | 34 |
11 | Rl Speed Signal | 36 |
12 | Rr Speed Signal | 43 |
26 | Ground | 33, 37, 42, 46 |
Calibrations of the AWD ECU
Users have the ability to adjust all the controls of the Syvecs AWD Unit via our Scal program that’s part of SSuite. This can be downloaded from https://www.syvecs.com/software/
The USB port for communication is found under the main connector which is protected with a Allen key plug. Remove the plug and connect a Micro USB Cable to the AWD Unit and the other side to a Windows Laptop or PC.
Open the Scal software and select Device – Connect Tab at the top. This will connect to the device and grab the calibration from it. If the unit has just been updated then no Cal will be present and Users need to program defaults or load a base map.
IMPORTANT:
The AWD Ecu can be connected to and programmed outside of the car as it will
power up of the USB cable alone. PLEASE NOTE: If you are connecting the Usb to
an Awd Ecu before the Unit is powered up from the car power systems it will
enter a bootloader state until a Device –Connect is preformed. If wanting to
connect to the unit in the car then connect the USB after the Ignition is ON
or perform a Device –Connect first to bring the unit into main code.
Green Maps can be changed live, Blue maps require a Device – Program for the calibration change to be flashed into the device.
When all calibration work is done, users must do a Device – Program so the
green maps which have been changed get flashed and stored in memory.
Main Code Updates
Please watch the help video here – https://youtu.be/i0j4O9mN82Y
Calibration Switching on the AWD ECU
The Syvecs AWD Unit allows for users to be able to adjust many aspects of the control strategies inside the AWD Ecu via either an external switch or via OEM controls / buttons with plug in AWD units.\
At the top of the Scal AWD Calibration tree you will find the Calibration Switch section which list all the maps that can be adjusted based on awdSelect position. There is 4 positions available which can be used to adjust multiple duty maps or if limp modes are active.
Users are able to see the active awdSelect position by viewing it via the
right item list. Double clicking on the item will bring up a larger gauge.
The R35GTR AWD unit sets the awdSelect position based on the follow OEM Trans Modes:
awdSelect 1: Normal Mode
awdSelect 2: R Mode
Syvecs Connector
R35GTR AWD Connector
Syvecs Description | iO4 Pinout | Car Note | Wire Gauge |
---|---|---|---|
PWRGND | A1 | Ground | 18 |
PWRGND | A2 | AWD Solenoid Negative | 18 |
H-Bridge1 | A3 | AWD Solenoid Positive | 18 |
H-Bridge2 | A4 | ||
H-Bridge3 | A5 | ||
H-Bridge4 | A6 | ||
12V HC | A7 | 12v Battery | 18 |
Kline/LinBus | A8 | ||
MagnetoResistive 1 | A9 | Available for R35GTR ABS +Wire | |
MagnetoResistive 2 | A10 | Available for R35GTR ABS +Wire | |
MagnetoResistive 3 | A11 | Available for R35GTR ABS +Wire | |
MagnetoResistive 4 | A12 | Available for R35GTR ABS +Wire | |
12V HC | A13 | 12v Battery | 18 |
Can0 H (1mb) | A14 | Slave Can | |
Can0 L (1mb) | A15 | Slave Can | |
12v IGSW | A16 | Ignition Switch Supply | 24 |
Can1 H (500kb) | A17 | Can H | 24 |
Can1 L (500kb) | A18 | Can L | 24 |
12V HC | A19 | ||
5v Out | A20 | 5v Supply for Pot | 24 |
AN1 | A21 | BurnOut Sw – Pull to Ground for ON | 24 |
AN2 | A22 | Adjustment Potentionmeter | 24 |
AN3 | A23 | ||
AN4 | A24 | ||
PWRGND | A25 | Ground for Pot and BurnOut Sw | 24 |
PWRGND | A26 | Ground | 18 |
This document is intended for use by a technical audience and describes a number of procedures that are potentially hazardous. Installations should be carried out by competent persons only.
Syvecs and the author accept no liability for any damage caused by the incorrect installation or configuration of the equipment.
Please Note that due to frequent firmware changes certain windows might not be
the same as the manual illustrates.
If so please contact the Syvecs Tech Team for Assistance.
Support@Syvecs.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>