Energrid V IV Series

  • Customizable status LED ring with RGB lights
  • Touchable button with 4.3″ colored LCD
  • Supports USB On-the-Go function
  • Data log events stored in the inverter
  • Self-consumption and Feed-in to the grid
  • Programmable supply priority for PV, Battery or Grid
  • User-adjustable charging current and voltage
  • Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
  • Built-in Wi-Fi for mobile monitoring (App is available)
  • Reserved communication port for BMS
  • Parallel operation up to 9 units

Specifications

Model| Phase| Maximum PV Input Power| Rated Output Power| Maximum Charging Power
---|---|---|---|---
Energrid V IV 3.6KM-48| 1-phase in / 1-phase out| 5000W| 3600W| 5000W
Energrid V IV 5.6KM-48| 1-phase in / 1-phase out| 6000W| 5600W| 6000W
Energrid V IV 6KM-48| 1-phase in / 1-phase out| 6500W| 6000W| 6000W
MODEL| Energrid V IV 3.6KM-48| Energrid V IV 5.6KM-48| Energrid V IV 6KM-48
---|---|---|---
PHASE| 1-phase in / 1-phase out
MAXIMUM PV INPUT POWER| 5000W| 6000W| 6500W
RATED OUTPUT POWER| 3600W| 5600W| 6000W
MAXIMUM CHARGING POWER| 5000W| 6000W| 6000W
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage| 360 VDC / 500 VDC| 360 VDC / 450 VDC| 360 VDC / 500 VDC
Start-up Voltage / Initial Feeding Voltage| 110VDC / 120 VDC| 110VDC / 120 VDC| 120VDC / 150 VDC
MPP Voltage Range| 120 VDC ~ 430 VDC| 120 VDC ~ 430 VDC| 120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current| 1 / 18 A| 1 / 27 A| 1 / 27A
GRID OUTPUT (AC)
Nominal Output Voltage| 220/230/240 VAC
Output Voltage Range| 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable)
Nominal Output Current| 15.6A| 24.3A| 26.1A
Power Factor| > 0.9
EFFICIENCY
Maximum Conversion E ciency (DC/AC)| 96%| 96%| 95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage / Auto Restart Voltage| 120 – 140 VAC / 180 VAC
Acceptable Input Voltage Range| 90 – 280 VAC or 170 – 280 VAC
Maximum AC Input Current| 40 A| 40 A| 40 A
PV INPUT (DC)
Maximum DC Voltage| 500 VDC| 450 VDC| 500 VDC
MPP Voltage Range| 120 VDC ~ 430 VDC| 120 VDC ~ 430 VDC| 120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current| 1 / 18 A| 1 / 27 A| 1 / 27 A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage| 220/230/240 VAC
Output Waveform| Pure sinewave
E ciency (DC to AC)| 93%| 93%| 93%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage| 360 VDC / 500 VDC| 360 VDC / 450 VDC| 360 VDC / 500 VDC
Start-up Voltage / Initial Feeding Voltage| 110VDC / 120 VDC| 110VDC / 120 VDC| 120VDC / 150 VDC
MPP Voltage Range| 120 VDC ~ 430 VDC| 120 VDC ~ 430 VDC| 120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current| 1 / 18 A| 1 / 27 A| 1 / 27A
GRID OUTPUT (AC)
Nominal Output Voltage| 220/230/240 VAC
Output Voltage Range| 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable)
Nominal Output Current| 15.6A| 24.3A| 26.1A
AC INPUT
AC Start-up Voltage / Auto Restart Voltage| 120 – 140 VAC / 180 VAC
Acceptable Input Voltage Range| 90 – 280 VAC or 170 – 280 VAC
Maximum AC Input Current| 40A| 40A| 40A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage| 220/230/240 VAC
E ciency (DC to AC)| 93%| 93%| 93%
BATTERY & CHARGER
Nominal DC Voltage| 48 VDC| 48 VDC| 48 VDC
Maximum Solar Charging Current| 100A| 120A| 120A
Maximum AC Charging Current| 100A| 120A| 120A
Maximum Charging Current| 100A| 120A| 120A
GENERAL
PHYSICAL
Dimension, D x W x H (mm)| 140 x 295 x 468
Net Weight (kgs)| 11| 12| 12
INTERACE
Parallel Function| Yes, 9 units
Communication Port| USB/RS232/RS485/Wifi/Dry-contact
ENVIRONMENT
Humidity| 0 ~ 90% RH (Non-condensing)
Operating Temperature| -10 to 50ºC

Product specifications are subject to change without further notice.

Product Usage Instructions

  1. Connect the Energrid V IV Series to a single-phase power source.
  2. Connect the PV input (DC) to the Energrid using the specified nominal and maximum DC voltages.
  3. Ensure the MPP voltage range is within the specified limits for optimal performance.
  4. Connect the grid output (AC) to the desired load using the specified output voltage range.
  5. For hybrid operation, connect the battery mode output (AC) to the load using the specified nominal output voltage.
  6. Ensure the AC input voltage is within the specified range for efficient charging.
  7. Make sure to follow the specified maximum input current for both DC and AC inputs.
  8. Use the USB/RS232 interface for monitoring and control purposes.

Prolink is a registered trademark of Fida International (S) Pte Ltd. Other brands and product names are trademarks or registered trademarks of their respective holders. Product images are purely for illustrative purposes and may defer from the actual product. Specifications are subjected to changes without prior notice. Copyright © 2023 Fida International (S) Pte Ltd.