prolink PVR500D Auto Voltage Regulator
Introduction
The PVR series is designed to automatically maintain a constant voltage level to protect sensitive electronics from brownouts and overvoltages. Equipped with comprehensive information display, it is easy to monitor the PVR s power status.
- Microprocessor control guarantees high reliability
- Selectable input voltage range
- Time delay function eliminates transients that can affect connected equipment
- Startup countdown time display (only available for the unit with digital display)
- Over-voltage, under-voltage, over-heat and over current protection
- Provides surge and spike suppression
Overview
PVR500D/PVR1000D
Legend:
- Time Delay Switch
- Input Voltage Range Selector
- Power LED (Green)
- AVR LED (Yellow)
- Over-Voltage/Under-Voltage Indicator (Red)
- Input Voltage Display
- Power LED (Green)
- Output Voltage Display/ Startup Countdown Display (Only for digital display)
- Handle (Optional for 500VA/1000VA)
- AC Input
- Output Socket
PVR2000D/PVR3000D
Legend:
- Time Delay Switch
- Input Voltage Range Selector
- Power LED (Green)
- AVR LED (Yellow)
- Over-Voltage/Under-Voltage Indicator (Red)
- Input Voltage Display
- Power LED (Green)
- Output Voltage Display/ Startup Countdown Display (Only for digital display)
- Handle (Optional for 500VA/1000VA)
- AC Input
- Output Sockets
- AC Input Terminal
- Grounding
- AC Output Terminal
- Output Socket
Installation
Inspection :
Remove AVR from the packaging to inspect if it is damaged.
Placement
Install AVR in a well protected environment.
-
Do NOT block the top or side air vents on the unit.
Please reserve 20cm space for ventilation. -
Do NOT operate the AVR where the temperature and humidity exceeds the specific limits.
(Please check the specs for the limitations.)
Connect Your Equipment
Plug equipment into the AVR rear-panel outlets. Then, switch on the unit by
pressing the front
panel power switch to “RESET” position.
Caution:
The total power consumption of all equipment plugged into the AVR must not
exceed its capacity (Refer to spec). It may damage the breaker.
Operation
Time Delay Switch
Delay: Set delay time to 3 minutes. It is designed to avoid damaging the connected devices from consecutive starts. This feature is perfect for devices with AC motor such as refrigerators, freezers, or dehumidifiers.
Underlay: Set delay time to 10 seconds. It is designed for voltage- sensitive equipment such as personal computers, monitors or home appliances like televisions, modems and telephone devices.
Input Voltage Range
110-270V: Setting acceptable input voltage range within 110-270V
140-260V: Setting acceptable input voltage range within 140-260V
RESET/ OFF Switch
When the input current exceeds the rated current, the over-current protection
will be triggered by cutting off the power supply and turning the switch to
the “OFF” position.
Press the “RESET” button to manually switch ON the AVR once the load
connection has been checked/ reduced if necessary.
Specification
MODEL | PVR500D | PVR1000D | PVR2000D | PVRJ000D |
---|---|---|---|---|
Capacity | S00VA/400W | lO00VA/B00W | 2000VA/1600W | 3000VA/2400W |
INPUT | ||||
--- | --- | |||
Voltage | 220VAC | |||
Voltage Range | 110 – 270VAC or 140-260VAC | |||
Frequency Range | S0Hz or 60Hz | |||
OUTPUT | ||||
Output Voltage | 220VAC | |||
Voltage Regulation | -10% ~ +10% | |||
EFFICIENCY | ||||
Normal Mode | 95% | |||
AVR Mode | 92% | |||
PHYSICAL |
Diamension
D x Wx H (mm)
| 197 X 110 X 124| 234 X 134 X 181| 297 X 150 X 199
---|---|---|---
Weight (kg)| 2.4| 3.91| 6.55| 8.56
ENVIRONMENT
Temperature | o·c – 4o•c |
---|---|
Humidity | 0 – 90% relative humidity (Non-condensing) |
DAFTAR LAYANAN PURNAJUAL:
-
PT. PROLINK INTI DATA NUSANTARA IJL. CIDENG BARAT NO. 79, JAKARTA PUSAT 10150 I Tel: 021-34831777
-
AT COMPUTER I RUKO KOMP SULTAN ADAM PERMAI, NO.13 BANJARMASIN
Tel: 0511-74044e6 -
PT. PROSHOP TIMUR RAYA I JL. RAYA MANYAR 69E SURABAYA RT.004 RW.010, MENUR PUMPUNGAN SUKOLILO SURABAYAJAWA TIMUR 60286 I 031-59173511
-
PT. ANDARU PRIMA HARSA IJL BRIGJEN KATAMSO NO 75-77 RT 044 RW 013, PRAWIRODIRJAN GONDOMANAN YOGYAKARTA 55655 I Tel: 0274- 420277
-
PT. DHARMA INTI TEKNOLOGI IJL TERONG NO 42 MAKASSAR, WAJO BARU – BONTOALA MAKASSAR, SULAWESI SELATAN I Tel: 0411- 459010
-
PT.ARTHANAYATEKNOLOGI IJL TEUKU UMAR NO 200 KOMPLEKS PERTOKOAN AGUNG RAYA NO 12, DAUH PURI KAUH – DENPASAR BARATDENPASAR-BALI 80113 I Tel: 0361-2096382
-
METRO KOMPUTER IJL. GAJAH MADANO.87 I Tel: 0561-741610
-
PT. DWIWIRAPUTRADINAMIICA IJL. SETIA BUDHI NO. 107A, PEKAN BARU I Tel: 0761 -36486
-
PT. SQUARE GORONTALO IJL. S. PARMAN NO.38 BIAWAO, KOTA SELATAN KOTA GORONTALO I Tel: 082188007111
-
PT. INTI SANHO UTAMATEKNOLOGI IJL. MENGGALA NO. 48 MEDAN I Tel: 061-7330800
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>