MEAN WELL XLG-200 Series 200W Constant Power Mode LED Driver Instruction Manual
- June 12, 2024
- MEAN WELL
Table of Contents
200W Constant Power Mode LED Driver
XLG – 200 series
User’s Manual
Features
- Wide input range 100~305V AC( Class |)
- Full power output at 70~100% Constant power mode operation
- Metal case with IP67, suitable for outdoor application
- Surge protection with 6KV/4KV (10KV/6KV optional)
- 3 in 1 dimming function (Dim to off and Isolation design)
- India (EESL) version with Input Over Voltage Protection can survive input voltage stress of 440Vac for 48 hours
- Protection functions: OVP/SCP/OCP/OTP
- Life time >50,000 hrs. and 5 years warranty
Applications
- Skyscraper lighting
- Street lighting
- Floodlight Lighting
- Stage lighting
- Fishing lighting
- Horticulture lighting
- Bay lighting
- DMX power supply
- Type HL for use in class |, Division 2
■ GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
XLG-200 series is a 200W LED AC/DC driver featuring the constant power mode.
XLG-200 operates from 100~305VAC and offers models with different rated
current ranging between 700mA and 16A. Thanks to the high efficiency up to
94%, with the fanless design, the entire series is able to operate for -40C
~+90 case temperature under free air convection. The design of metal housing
and IP67 ingress protection level allows this series to fit both indoor and
outdoor applications. Moreover the innovative environment-adaptive capability
allows this series to reliably light on the LEDs for all kinds of application
environments in almost any spots that may install LED luminaires in the world.
XLG-200 series comply with the latest version of IEC61347/GB7000.1-2015 and
UL8750 international safety regulations. The output and dimming circuit are
also completely in accordance with the new regulations with isolation to
ensure the safety of both user and luminaire system during installation.
■ Model Encoding
Type | Function | Note |
---|---|---|
Blank | lo and Vo fixed.(For harsh environment) | By request |
A | lo adjustable via built-in potentiometer | In Stock |
AB | lo adjustable via built-in potentiometer + 3 in 1 dimming function | |
(0-10Vdc, 10V PWM signal and resistance) | In Stock |
Note:
- 12V and 24V models without AB type
- India version needs MOQ for production, please consult MEANWELL for detail
SPECIFICATION
MODEL | XLG- 200 ▢ -12-▢ | XLG-200 ▢ -24- ▢ |
---|---|---|
OUTPUT | DC VOLTAGE | 12V |
CONSTANT CURRENT REGION Note.2 | 8.4~ 12V | 16.8~ 24V |
RATED CURRENT (Default) | 16A | 8.3A |
RATED POWER | 192W | 199.2W |
RIPPLE & NOISE (max.)
Note.3| 150mVp-p| 240mVp-p
CURRENT ADJ. RANGE| Adjustable for A-Type only (via the built-in
potentiometer)
8 ~ 16A| 4.15 ~ 8.3A
VOLTAGE TOLERANCE Note.4| ±3.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%
LOAD REGULATION| ±2%| ±1%
SETUP, RISE TIME
Note.6| 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC
HOLD UP TIME (Typ.)| 10ms/ 230VAC 10ms/ 115VAC
INPUT| VOLTAGE RANGE
Note.5| 100 ~ 305VAC
142 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
TOTAL HARMONIC DISTORTION| THD< 10%(@load≧50%/115VC,230VAC;
@load≧75%/277VAC)
EFFICIENCY (Typ.)| 92%| 94%
AC CURRENT| 2.2A / 115VAC 1.1A / 230VAC 0.9A/277VAC
INRUSH CURRENT(Typ.)| COLD START 65A(twidth=550μs measured at 50% Ipeak)
at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 3 units (circuit breaker of
type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
NO LOAD POWER CONSUMPTION| No load power consumption <0.5W(for standard
version)
PROTECTION| OVER CURRENT| 95 ~ 108%
Hiccup mode or constant current limiting, recovers automatically after fault
condition is removed
SHORT CIRCUIT| Hiccup mode or constant current limiting, recovers
automatically after fault condition is removed
OVER VOLTAGE| 13.5 ~ 18V| 27 ~ 34V
Shut down output voltage, re-power on to recover
INPUT OVER VOLTAGE Note.7| 320 ~ 390VAC (Shut down output voltage
when the input voltage exceeds protection voltage,recovers automatically after
fault condition is removed)
Can survive input voltage stress of 440Vac for 48 hours @ tc 75℃ max
OVER TEMPERATURE| Shut down output voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| Tcase=-40 ~ +90℃ (Please refer to “
OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +90℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS Note.7| UL8750(type”HL”), CSA
C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS
EN/EN62384;GB19510.1, GB19510.14;EAC TP TC 004;J61347-1(H29),
J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-200I type
only );
NOM-058-SCFI-2017(except for Blank type);IP67 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Parameter| Standard| Test Level/Note
Conducted| BS EN/EN55015(CISPR15) ,GB/T17743| —–
Radiated| BS EN/EN55015(CISPR15) ,GB/T17743| —–
Harmonic Current| BS EN/EN61000-3-2 ,GB/T17625.1| Class C @load≥50%
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61547
Parameter| Standard| Test Level/Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT/Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| 4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS| MTBF| 2300.1K hrs min. Telcordia SR-332 (Bellcore) ; 200.7Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 1996335.5mm (LWH)
PACKING| 0.85Kg;16pcs /14.2Kg /0.72CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Please refer to “DRlVlNG METHODS OF LED MODULE”.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to “STATlC CHARACTERlSTlC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. lnput over voltage only for XLG-200 l series ,and l series without UL/CSA certificate.
8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly point (or TMP, per DLC), is about 75℃ or less.
10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
12. Products sourced from the Americas regions may not have the CCC/PSE/BlS/KC logo. Please contact your MEAN WELL sales for more information.
13. For any application note and lP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
14. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
15. lf you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details.
MODEL| XLG-200◻ -L- ◻| XLG-200 ◻ -H-◻
---|---|---
OUTPUT| RATED CURRENT (Default)| 700mA| 3500mA
RATED POWER| 200W| 200W
CONSTANT CURRENT REGION Note.2| 142 -285V| 27 – 56V
FULL POWER CURRENT RANGE| 700-1050mA| 3500-5550mA
OPEN CIRCUIT VOLTAGE (max.)| 300V| 60V
CURRENT ADJ. RANGE| Adjustable forA/AB-Type only (via the built-in potentiometer)
350-1050mA| 1750-5550mA
CURRENT RIPPLE| 3.0%(@ Load?-:50% rated voltage)
CURRENT TOLERANCE| ±5%
SET UP TIME Note.4| 500ms/230VAC, 1200ms/115VAC
INPUT| VOLTAGE RANGE Note.3| 100 – 305VAC 142VDC – 431VDC
(Please refer to ‘STATIC CHARACTERISTIC’ ang – DRIVING METHODS OF LED MODULE- section)
FREQUENCY RANGE| 47- 63Hz
POWER FACTOR T
( yp.)| PF 0.97 / 115VAC, PF – 0.95 / 230VAC, P F i: 0.92 / 277VAC at full load
(Please refer to ‘Power Factor Characteristic’ section)
TOTAL HARMONIC DISTORTION| TH D< 10% (@ load> 50% at 115VAC/230VAC ,@load> 75% at 277VAC) Please refer to ‘TOTAL HARMONIC DISTORTION (TH D)° section
EFFICIENCY (Typ.)| 94% 193%|
AC CURRENT (Typ.)| 2.2A/ 115VAC 1.1A/ 230VAC 0.9A/ 277VAC
INRUSH CURRENT(Typ.)| COLD START 65A(twethr550ps measured at 50% !pea) at 230VAC; Per NEMA 410
MAX. NO. of PSUson 16A CIRCUIT BREAKER| 3 unit(circuit breaker of type B) /6 units(circun breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA/ 277VAC
STANDBY
POWER CONSUMPTION| Standby power consumption <0.5W for AB-Type(Dim ming OFF)(for standard version)
PROTECTION| SHORT CIRCUIT| Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 301 – 360V| 161 – 85V
Shut down output voltage, re-power on to recovery
INPUT OVER VOLTAGE Note.5| 320 – 390VAC (Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed)
Can survive input voltage stress of 440Vac for 48 hours @ tc 75`C max
OVER TEMPERATURE| Shutdown output voltage, re-power on to recover
ENVRONMENT| WORKING TEMP.| Tcase=-40 – +90″C (Please refer to ‘OUTPUT LOAD vs TEMPERATURE’ section)
MAX. CASE TEMP.| Tcaser+90t
WORKING HUMIDITY| 20 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +80″C , 10 – 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/t (0 – 60″C )
VIBRATION| 10 – 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS Note.5| UL8750(type’HL’), CSA C22.2 No. 250.13-12; BS EN/ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384;GB19510.1,
GB19510.14;EAC TP TC 904; J61347-1(H29), J61 347-2-1 3(H29),KC61347-1.KC61347-2-13,IS15885(Part2/Sec13)(for XLG-200I type only); NOM-058-SCFI-2017(except for Blank type);IP67 approved
WITHSTAND VOLTAGE| UP-0/P:3.75KVAC 1/P-FG:2KVAC 0/P-FG:1.5KVAC
ISOLATION RESISTANCE| UP-0/P, I/P-FG, 0/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/E N55015, BS EN/E N61000-3-2 Class C (@ load ?_50%); BS EN/EN61000-3-3
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,1 1, BS EN/EN61547, light industry level (surge immunity Line-Earth 6KV , Line-Line 4KV) (101Q6KV option)
EMC EMISSION| Parameter| Standard| Test Level/Note
Conducted| BS E N/E N5501 5(C I SPR15) ,GB/T1774 3|
Radiated| BS EN/EN55015(CISPR15) ,GB/T1 7743|
Harmonic Current| BS E N/E N61000-3-2 ,GB/T17625.1| Class C @loada50%
Voltage Flicker| BS EN/EN61000-3-3|
EMC IMMUNITY| BS EN/EN61 547
Parameter| Standard| Test Level/Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT/Burst| BS EN/EN61000-4.4| Level 3
Surge| BS EN/EN61000-4-5| 4KV/Line-Line 6KV/Line-Earth (6KJ10K option)
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61 000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods
OTHERS| MTBF| 2300.1K hrs min.
Telcordia SR-332 (Bellcore) ;
200.7Khrs milt
MIL-HDBK-217F (25°C)
DIMENSION| 199″6335.5mm (L-VV-H)
PACKING| 0.85Kg;16pcs/14.2Kg/0.72CUFT
NOTE| 1.All parameters NOT specially mentioned are measured at 230VAC input rated current and 25C of ambient temperature.
2.Please refer to ‘DRIVING METHODS OF LED MODULE.
3.De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC’ sections for details.
4.Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
5.Input over voltage only for XLG•200 I series and I series without UUCSA certificate.
6.The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must requalify EMC Directive on the compininstallation again.
7.This series meets the typical life expectancy of >50,000 hours of operation when Tease, particularly point (or IMP, per DLC), is about 75 C or less.
8.Please refer to the warranty statement on MEAN WELLS website at http://www.meanwell.com
9.The ambient temperature derating of 3.5 C /1000m with fanless models and of 5 C/1000m with fan models for operating altitude higher than 2000m(6500ft).
10.To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to
the mains.
11.Products sourced from the Americas regions may not have the CCC/PSE,BISIKC logo. Please contact your MEAN WELL sales for more information.
12.For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.c0m/Upload/PDF/LED_EN.pdf
13.Ripple & noise are measured at 20MHz of bandwidth by using a 12′ twisted pair-wire terminated with a 0.1 of & 47uf parallel capacitor.
14.To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
15.If you need the NOM (Mexico) certificate. Please contact MEAN WELL sales representative for details.
■ BLOCK DIAGRAM
PFC fosc : 50~120KHz
PWM fosc : 60~130KHz
■ DRIVING METHODS OF LED MODULE
※ I-V Operating Area
XLG-200-L | XLG-200-H |
---|
|
Recommend Performance Region| Recommend Performance Region
XLG-200-12,24
※ This series is able to work in either Constant Current mode (a direct drive
way) or Constant Voltage mode (usually through additional DC/DC driver) to
drive the LEDs.
DIMMING OPERATION
※ 3 in 1 dimming function (for AB-Type)
- Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
- Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
- Dimming source current from power supply: 100 A (typ.)μ
◎ Applying additive 0 ~ 10VDC
◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
◎ Applying additive resistance:
Note :
- Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.
- The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
OUTPUT LOAD vs TEMPERATURE
If XLG-200 operates in Constant Power mode with the rated
current the maximum workable Ta is 50℃ (Typ. 230VAC) or 40℃ (typ.110VAC)
Below 110VAC@30℃ may retry to 2nd setup
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
※ Tcase at 75℃
TOTAL HARMONIC DISTORTION (THD)
※ XLG-200-L Model, Tcase at 75 ℃
EFFICIENCY vs LOAD
XLG-200 series possess superior working efficiency that up to 94% can be
reached in field applications.
※ XLG-200-L Model, Tcase at 75 ℃
LIFE TIME
MECHANICAL SPECIFICATION
※ Blank-Type
※ A-Type
※ AB-Type
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
File Name:XLG-200-SPEC 2022-08-08 Downloaded from Arrow.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>