BRILONER MAL 3754 LED Ceiling Dimmable Light Instruction Manual

June 12, 2024
BRILONER

MAL 3754 LED Ceiling Dimmable Light
Instruction Manual MAL 3754
Mounting instructions

MAL 3754 LED Ceiling Dimmable Light

HORNBACH MAL 3754 LED Ceiling Light -

Safety directions

Please read this information carefully before installing or using this product. Please keep this user manual for further reference.

  1. The lamps may only be installed by authorized and qualified technicians according to the valid regulations for electrical installation.

  2. The manufacturer does not accept any responsibility for injuries or damage resulting from improper use of the light.

  3. Maintenance of the lights is limited to the surfaces. For electrical safety reasons, this product must not be cleaned with water or other liquids. Use only a dry, lint-free cloth for cleaning.

  4.   Caution!  Risk of electric shock. Before connecting to the mains, always check the entire light for possible damage. Never use the light if you notice any damage.

  5.   Caution!  Disconnect the main cable from the power supply before assembling or disassembling. Switch off the earth leakage circuit breaker/automatic circuit breaker or unscrew the fuse. Turn the switches to “OFF”.

  6. **Caution!**  Before drilling the mounting holes, make sure that no gas, water, or electricity pipes and wires can be drilled through or damaged in your chosen mounting location.

  7. When mounting, ensure that the attachment material is suitable for the subsurface and that this surface is capable of carrying the weight of the fixture. The manufacturer is not liable for improper installation of the item on the relevant subsurface.

  8.  The symbol of the crossed-out garbage can on the product or the packaging means that the product must not be disposed of with ordinary household waste. At the end of its useful life, the product must be returned to a point of acceptance for the recycling of electric and electronic devices. Please ask your local municipality for the point of acceptance.

  9. Safety class II  ****. This light is specially insulated and must not be connected to an earthed conductor.

  10. Safety class II. Take note that when switching on that the building site supply lines available have double or reinforced insulation up to the terminal connection area. The
    enclosed terminal box ensures that when the building site conductors with basic insulation have a maximum length of “80 mm“. Description of the supply terminals: L = Phase N = Neutral conductor ****= Earthed conductor.

  11. Protective covers and end covers for mains voltage control parts must always be mounted.

  12. Do not install the light on a damp or conductive subsurface. Please make sure that no cables get damaged during the installation work.

  13.   Attention!  During operation, lamp parts and illuminants can reach temperatures of more than 60°C. Do not touch during operation!

  14. The lights have a protection class rating of “IP20“ and are solely intended for indoor use only in private households.

  15. Do not look directly into the light source (illuminant, LED, etc.).

  16. The included or insertable light bulb contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similarly qualified person.

  17.  The operating device (transformer, ballast, control unit, etc.) may only be replaced by the manufacturer or trained personnel.

  18. This product contains light sources of the energy efficiency classes “2 x E“, based on the EU regulation 2019/2015. Reference setting: “6500K“.

  19. LED color deviation when using different chargers may occur. The light color and luminous strength of the LEDs can also change as a result of the life span level of the lamp.

  20. This article is not suitable for use with dimmable electric circuits. It can be controlled using the accompanying remote control.

  21. “Broner Leuchten“ hereby declares that the radio equipment type “3754“ complies with the directive “2014/53/EU“. The complete text of the EU Declaration of Conformity is available at the following web address: https://www.briloner.com/eu-konformitaetserklaerung

  22. This product works with an operating frequency of “433,92 MHz” and transmission power of “max. 6 dBm”.

  23. Available functions of the product:

  24. Switching on the lamp with the “ON/OFF CCT“ button on the remote control does the following: Only the “CCT“ area will be switched on.

  25. Switching on the lamp with the “ON/OFF RGB“ button on the remote control does the following: Only the “RGB“ area will be switched on.

  26. Pressing “CCT/RGB” several times switches between Controlling the CCT-LEDs / Controlling the RGB-LEDs.

  27. The “Dim+“ and “Dim-“ buttons brighten and dim the lights either in stages or continuously. The speed of a lighting effect selected using the “RGB” button can be changed using this button.

  28. The “Cool” and “Warm” buttons move the color temperature closer to cool white or warm white either in stages or continuously. This also applies to the “RGB” mode with the color- / Color+ buttons (manual color setting).

  29. The “Night Light” button switches the lights to their dimmest setting with a color temperature of approximately “2700K”.

  30. The “Timer” button switches the lights off after “30” minutes.

  31. Activation of the “RGB” button starts a continuous, infinitely variable color flow of all colors.

  32. Should the control of the article by remote control not be possible, then it may be necessary to train the article once again.

  33. The procedure is explained as follows: a. Connect: Turn on the light at the wall switch and immediately after pressing the button „ON/OFF CCT“ “3 sec.“, beginning in a time window of “1“ second. The light will confirm the process with a flash “2 x“. b. Disconnect: Turn on the light at the wall switch and immediately after pressing the button „CCT/RGB“ “3 sec.“, beginning in a time window of “1“ second. The light will confirm the process with a flash “2 x“.

  34. Memory function: switching on the light using the remote control or an external light switch always activates the last light color and dimming level set.

  35. Batteries or rechargeable batteries are not permitted in domestic waste. They must be decontaminated according to the regulations of the responsible authorities as hazardous waste. Use the available collection points.

BRILONER®
DECLARATION OF CONFORMITY
We
Briloner Leuchten GmbH & Co KG Im Kissen 2, 59929 Brilon
Declare on our own responsibility that
the device
Fixed general purpose luminaires
Type or model

3733-019
3753-019| 3735-015
3754-015| 3736-015
3754-019| 3739-015
3755-015| 3753-015
3755-019
---|---|---|---|---

Meets all the requirements of the following Directives and Regulations

Directives 2014/53/EU 2014/35/EU 2009/125/CE Reglement 2019/2020

Applied harmonized standards:

EN IEC 55015:2019
EN IEC 55015:2019+A11:2020
EN IEC 61000-3-2:2019+A1:2021
EN61000-3-3:2013+A1:2019
EN61547:2009 ETSI
EN 300 220-2 V3.2.1
EN50663.2017| EN60598-1:2015+A1:2018
EN60598-2-1:1989
EN IEC 62031:2020
EN61347-1:2015
EN61347-2-13:2014+A1:2017
EN62493:2015 EN62471:2008
---|---

The object of the declaration described above is in conformity with Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment

****Applied harmonized standard:
Signed for and on behalf of:
EN IEC 63000:2018
Briloner Leuchten GmbH & Co KG Im Kissen 2, 59929 Brilon 15. Marz 2022
00800/BRILONER (00800/27456637) Briloner Leuchten / Im Kissen 2 / 59929 Brilon

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals