TFA Dostmann 60.4520.01 Radio Wall Clock Instruction Manual
- June 12, 2024
- TFA Dostmann
Table of Contents
**Operating Instructions
Instruction manual
Thank you for choosing this instrument from TFA.
Before you use this product
- Please make sure you read the instruction manual carefully.
- The operating instructions are enclosed with the device or can be downloaded at www.tfa-dostmann.de/en/service/downloads/instructionmanuals
- This product should only be used as described within these instructions.
- Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
- Please take particular note of the safety advice!
- Please keep this instruction manual safe for future reference.
Radio-controlled clock with indoor climate
-
There are three different reception states:
flashing – Reception is active
remains – Reception is successful
disappears – No reception -
If the clock cannot detect the DCF-signal (e.g. due to interference, transmitting distance, etc.), the time can be set manually.
5.3 Note on radio-controlled time
- The time is transmitted from an atomic clock near Frankfurt am Main by a DCF-77 (77.5 kHz) frequency signal with a range of about 1,500 km. Your radio-controlled clock receives the signal, converts it and always shows the exact time. The adjustment of Daylight Saving Time and Standard Time is also automatic.
- Make sure to avoid the vicinity of any source of interference such as computer screens, TV sets or solid metal objects. Within concrete walls (reinforced with steel) such as basements, the received signal is naturally weakened. In extreme cases, please place the unit close to a window to improve reception.
- During night-time, the atmospheric interference is usually less severe. A single daily reception is adequate to keep the accuracy deviation under 1 second.
Operation
6.1 Manual settings
-
Press and hold the SET button for three seconds to enter the setting mode.
-
The first adjustable value flashes on the display.
-
Use the UP or DOWNbutton to make the desired setting.
-
Confirm with the SET button and go to the next setting.
-
The sequence is shown as follows:
– Time zone -12/+12 (default: ZONE 00)
– Day-of-week language: (default: German)
– Year, month, day
– Hours, minutes
– DCF reception on/off (default: RCC ON) -
Press and hold the UP or DOWN button in the respective setting mode for quick setting. The device will automatically quit the setting mode if no button is pressed for 15 seconds.
6.1.1 Time zone setting
- In the setting mode you can make the time zone correction
- The time zone correction is needed for countries where the DCF signal can be received but the time zone is different from the DCF time (e.g. +1=one hour plus).
Radio-controlled clock with indoor climate
6.1.2 Day-of-the week language
- In the setting mode you can set the day-of-the week language: GERMAN, FRENCH, SPANISH, ITALIAN, DANISH, DUTCH, SWEDISH and ENGLISH.
6.1.3 DCF reception
- By default, the DCF reception is activated (RCC ON) and after successful reception of the DCF signal no manual adjustment is necessary.
- Once the DCF time reception is deactivated (RCC OFF), the clock and date must be manually set.
- If the DCF reception is activated, the manually set time will be overwritten by the DCF time when the signal is received successfully.
Alarm time setting
- Press the ALARM button in normal mode to enter the alarm mode. AL and the last adjusted alarm time appear on the display.
- Press and hold the ALARM button for three seconds to enter the setting mode.
- The hour digits flash.
- Press the UP or DOWN button to adjust the hours.
- Confirm the setting with the ALARM button and set minutes in the same way.
- Press the ALARM button again to return to the current time.
- The alarm is activated and the alarm symbol appears on the display.
- To deactivate/activate the alarm, press the UP button in alarm mode.
- The alarm symbol disappears/appears on the display.
- When the alarm is activated, the alarm starts to ring when the set alarm time is reached. The alarm symbol flashes.
- Press any button (except SET) and the alarm will stop.
- Press the SET button to activate the snooze function.
- The alarm will be interrupted for about 5 minutes.
- The snooze symbol flashes.
- Press any button to stop the snooze function.
Battery replacement
- Change the batteries when the battery symbol appears on the display.
Troubleshooting
Problem | Solution |
---|---|
No display | ➜ Ensure the batteries’ polarities are correct |
➜ Change the batteries
No DCF reception| ➜ Activate DCF reception in setting mode (RCC ON)
➜ Start the initialization manually
➜ Wait for an attempt reception during the night
➜ Choose another place for your device
➜ Set the clock manually
Incorrect indication| ➜ Press the RESET button
➜ Change the batteries
If your device fails to work despite these measures, contact the retailer where you purchased the product.
Waste disposal
This product and its packaging have been manufactured using high-grade
materials and components which can be recycled and reused. This reduces waste
and protects the environment.
Dispose of the packaging in an environmentally friendly manner using the
collection systems that have been set up.
Disposal of the electrical device
Remove non-permanently installed batteries and rechargeable batteries from the
device and dispose of them separately.
This product is labelled in accordance with the EU Waste Electrical and
Electronic Equipment Directive (WEEE).
This product must not be disposed of in ordinary household waste. As a
consumer, you are required to take end-of-life devices to a designated
collection point for the disposal of electrical and electronic equipment, in
order to ensure environmentally-compatible disposal. The return service is
free of charge. Observe the current regulations in place!
Disposal of the batteries
**** Never dispose of empty batteries and rechargeable batteries with
ordinary household waste. They contain pollutants which, if improperly
disposed of, can harm the environment and human health. As a consumer, you are
required by law to take them to your retail store or to an appropriate
collection site depending on national or local regulations in order to protect
the environment. The return service is free of charge.
The symbols for the contained heavy metals are: Cd=cadmium, Hg=mercury,
Pb=lead.
Specifications
Power consumption: | 4 x AA 1,5 V batteries (not included) |
---|---|
Measuring range temperature | -10°C … 50°C |
Measuring range humidity | 1…99% |
Display LL.L /HH.H | Temperature is outside measuring range |
Housing dimension | 360 x 235 x 28 (84) mm |
Weight | 869 g (device only) |
No part of this manual may be reproduced without written consent of TFA
Dostmann. The technical data are correct at the time of going to print and may
change without prior notice.
The latest technical data and information about this product can be found in
our homepage by simply entering the product number in the search box.
EU Declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 60.4520 is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address: www.tfa-
dostmann.de/service/downloads/ce
https://www.tfa-dostmann.de/en/produkt/digital-xl-radio-controlled-wall-
clock-with-room-climate-2/#product-information
Instruction manuals
www.tfa-dostmann.de/en/service/downloads/instruction-manuals
Kat. Nr. 60.4520.01
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, 97877 Wertheim, Germany
12/22
References
- Testseite für dostmann.de
- ᐅ Messgeräte, die begeistern | TFA Dostmann
- Customer Service | TFA Dostmann
- Kundenservice | TFA Dostmann
- EU-Konformitätserklärung | TFA Dostmann
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>