olympia electronics BS-850-KIT Wireless Programmable WiFi Electronic Chrono Thermostat User Manual
- June 12, 2024
- olympia electronics
Table of Contents
- BS-850-KIT Wireless Programmable WiFi Electronic Chrono Thermostat
- CONTROL AND INDICATIOR DESCRIPTION
- Setting up the device
- GENERAL
- FACTORY DEFAULT VALUES
- DAILY PROGRAMMING EXAMPLE
- WEEKLY PROGRAMING EXAMPLE.
- WIRELESS CONNECTION SETTING
- COMMUNICATION ERROR
- Installation procedure
- Warnings and safety information
- TECHNICAL CHARACTERISTICS
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BS-850-KIT Wireless Programmable WiFi Electronic Chrono Thermostat
User Manual BS-850/KIT, BS-851/KIT
**** WIRELESS PROGRAMMABLE WIFI ELECTRONIC CHRONO
– THERMOSTAT WITH HEATING FUNCTION AND BOILER OUTPUT
BS-850-KIT Wireless Programmable WiFi Electronic Chrono Thermostat
- Wireless connection between thermostat and commands of Relay.
- Connection with WiFi.
- Controlled from the smartphone.
- RF signal strength indicator.
- 3 operation modes: manual, daily and weekly.
- 8 key easy operation.
- Easy programm entry.
- Multiply indication screen with backlight.
- Clock, Calendar.
- Keypad lock
- Selection of upper and lower limits for manual temperature selection.
- Boiler operation (BS-851/Τ) with selectable time.
- Easy connection – adjustment.
Thank you for your trust in our products
Olympia Electronics – European manufacturer
CONTROL AND INDICATIOR DESCRIPTION
-
Thermostat activation
-
Thermostat deactivation
-
Increase value
-
Decrease value
-
Presence indicator
-
Thermostat active
-
Thermostat inactive
-
Battery state indicator
-
Ascending or descending temperature indicator
= When the selection is less than the actual temperature.
= When the selection + the differential is more than the actual temperature.
= When the temperature is between the selection and the selection the + differential. -
Hour and message display
-
Temperature and message display
-
Temperature units display
-
Active burner output display
-
Selecting on not the area presence program
-
Escape from a selection
-
Activate / Deactivate boiler (valid only for the BS-851/T)
-
Go to the next item or selection
-
Select normal or night program
-
Go to the previous item or selection
-
Select and confirm installation settings
-
Daily program activation indicator
-
Weekly program activation indicator
-
Manual program activation indicator
-
Day of the week indicator
-
Night program activation indicator
-
Burner activation indicator
-
Boiler activation indicator (valid only for the BS-851/R)
-
Normal program activation indicator
-
Power supply and programming status indicator
-
Burner activation indicator
-
Boiler activation indicator (valid only for the BS-851/R)
Setting up the device
1. SMARTPHONE CONNECTION
-
For Android download for free our application from Google Play by scanning with your smartphone the QR code (Figure 2a) or make a search typing “Olympia electronics thermostat”. For iOS download for free our application from App Store by scanning with your smartphone the QR code (Figure 2b) or make a search typing “Olympia electronics thermostat”.
https://play.google.com/store/apps/details?id=gr.olympia_electronics.thermostat&hl=elhttps://apps.apple.com/gr/app /olympia-electronics-thermostat/id1456612713 -
In the start up screen press No account yet? Create one (Figure 3). After finishing the process successfully you will have to confirm the e-mail address that you registered. With these data you can log in.
-
If you want to add a device to your home network firstly you have to connect your smartphone to the network which your thermostat will be connected.
-
To add the thermostat to the application: In the application touch the ‘+’ icon to the bottom left corner of the screen (Figure 4).
By selecting scan the QR Code with the camera scan the serial number located inside the receiver or scan the QR Code on the included card. Otherwise you can insert the serial number by typing the 32digit on the included card. -
To set up the parameters of WiFi you can do this either selecting WPS either Smart Config (Figure 5):
By WPS Push the WPS button (Figure 1) and the receivergetsin WP Smode.
Subsequently you have to push the WPS button on the router as shown in your smartphone’s screen (Figure 6).
By Smart Config
In field SSID (Figure 7) the name of the WiFi that you want to connect your thermostast must be visible. In field password (Figure 7) put the password of the WiFi. Subsequently you have to push the Manual button (Figure 1) on the thermostat and at the end the SEND icon from the application (Figure 7).
When they connect, the LD4 must blink every 2 seconds while the LD5 must be
off which means there is internet connection.
By finishing the process successfully you will be able to guide to the main
screen of the app and your device will be visible, furthermore you can control
it.
The screen of the thermostat is refreshing every five minutes, therefore, the
command from your smartphone might not be visible to the screen immediately
but this does not mean that it is not executed.
Note 1: Through Olympia Thermostat App, by pressing the ‘+’ button on the
right side of the screen, a capability of adding more than one device with
different serial number is feasible.
Note 2: The thermostat, either BS-851 or BS-850 could be controlled by
more than one user, when the users (or the smart phones) are solely logged in
to the same email account.
GENERAL
When the plastic battery separator is removed the unit is automatically activated and shows all the screen indicators for 1″,then the firmware version is shown and finally the screen enters final operation status. In the center of the screen you can see the current temperature. The clock has the hour 00:00, the date is 1 January (Friday) 2016 and the thermostat is inactive (OFF state). In this state the only available selection sare Boiler activation /deactivation (only for BS-851/ΚΙΤ) and entry to the settings menu. If the key is pressed momentarily, the screen illumination will be activated for 2″ and the symbols , and ΜΑΝ will be shown which are the factory defaults.
1. ENTERING THE MENU (the thermostat in the OFF state).
To enter the menu settings press the button for more than 3″.
The screen will be illuminated and will stay illuminated during all the
duration of the settings To navigate through the menu items use the keys and .
To change the value of a menu item use the keys and . Press the key to accept
the change or press the key to go to the previous state. By pressing again the
key our settings are saved. If no key is pressed for 2 minutes then the
thermostat returns to normal operation while saving the changed settings.
2. SELECTING DAY OR NIGHT OPERATION MODE
(the thermostat is in the ON state and in manual operation).
If the key is pressed for more than 3″ then the indication is deactivated and
you can see the . This means that night operation mode has been selected. This
selection replaces temporarily the manually selected temperature for as long
as the night program is active. If one of the keys or is pressed then the set
night program temperature is shown. (this can be changed from the setting
(night) of the ΜΕΝU). The factory default night temperature is set to 18.0ºC.
To deactivate the night program, press the key for more than 3″, the symbol is
replaced by the symbol .
3. Boiler ACTIVATION (available only on the BS-851/T).
This capability can be executed by pressing briefly the key, the backlight
will be activated for 2″ and the symbol will be shown on the top left corner
of the screen.
The built-in relay will send the command to the burner. The command will be
active for as long as it has been preselected via the ΜΕΝU setting with the
indication (Boiler time), or until the key is pressed again. If the
preselected Boiler value is 00 then the deactivation can be done only with the
key. The Boiler command is independent from the other functions of the device
and can be given even if the thermostat is deactivated (OFF state). The
factory default Boiler time is 00 minutes.
4. AREA PRESENCE SELECTION (The thermostat is in the ON state).
In normal operation, the symbol shows the presence of people in the area and
all the programs, which ever are selected, are executed normally. In limited
absence from the area (from a few hours to a few days) there is the capability
to execute the absence program.
If the key is pressed for 3″, the backlight will be activated for 2″ and the
symbol will be changed to .This command superimposes every other program. The
selected temperature is shown on the screen if any of the or keys is pressed
and can’t be changed.
The value can be changed only with the selection (Absent temperature) of the
ΜΕΝU. The factory default setting of this temperature is 16.0 ºC and can be
altered from 6.0 to 30.0 ºC. To deactivate the absence mode, the key must be
pressed for 3″, then the thermostat will continue the execution of the program
that was running before absence mode was selected.
5. KEYPAD LOCK (in any operation state).
If the keys and are pressed simultaneously for 3″ (first the key and then the
), the screen will show the message and the keypad is locked. Which ever key
is pressed after this will show the same message on the screen. All other
function are executed normally.
To unlock the keypad follow the same procedure and the screen will show the
message .
6. SETTING THE TIME AND DATE (the thermostat is in the OFF state).
To enter time and date adjustment mode press the key for 3″ as mentioned in
paragraph 1. The backlight will be activated and the lower section of the
screen will flash the message (Set Time). After that press briefly the key and
the hours indicators will start to blink. Use the keys or to set the correct
time. Pressing the key will cause the minutes indicators to blink and with the
keys or change to the correct value.
Pressing again the key you can adjust consecutively the year, month and date.
You can see that the day names are changed automatically depending on the
year, month and date. In normal operation the clock has leap year and daylight
savings time correction.
7. SETTING THE DAILY PROGRAM.
(the thermostat is in the OFF state).
If immediately after entering the MENU parameters press the key then the
blinking message (Day) will be shown on the bottom of the screen and the word
DAY on the top right. By pressing the key the message (Program 1) is shown in
place of the message.
In the center of the screen and if programming is done for the first time you
can see the message . By pressing the key the hours indicators blink and you
can alter the setting by using the keys or . By pressing the key you can alter
the minutes and the required temperature. With the key you can return to the
initial position with the blinking . With consecutive presses of the key you
can select the remaining programs of the 24 hour cycle (10 in total) and can
set the required time periods and temperatures as described above. Please note
that for every program define only the start time since the end time is the
start time of the next program. For example, if you desire a temperature of
23.0º C from 14:00 to18:00 in program 1 set the start time 14:00 at 23.0º C
and the start time of the second program 18:00 with the desired temperature.
The 24 hour time base starts at 00:00 and ends at 23:59′.
The start time of the next program must also be bigger than the start time of
the previous. If no more changes are required and when the program indicator
is blinking (e.g. ) you can press the key to store all the changes and the
screen will show the message . The programs that have not been adjusted are
not taken into account.
8. ADJUSTING SETTINGS FOR THE WEEKLY PROGRAM. (the thermostat is in the
OFF state).
If immediately after entering the ΜΕΝU press the key for 2 times the message
(7days) will be shown on the bottom of the screen and the word WEEK on the top
right. On the top left of the screen there is the message ΜΟ (Monday) that
shows the day that corresponds to the programming that follows. By pressing
again the key the screen shows a blinking that determines the first program of
Monday of the weekly program.
The remaining procedure is as described in paragraph 7 (setting the daily
program).
Finishing the programming of the first day if you press the key while the
program number is blinking (e.g. ) will show the blinking message . With the
key you can select the day for which you want to alter the program as
described above. If no other changes are required then press the key to save
the setting to memory. The screen will show the message . It is stressed that
at least one program must be adjusted for every day else the factory default
temperature of 6.0 ºC will be used
for all the 24 hour base.
9. SELECTING THE UPPER AND LOWER LIMITS OF THE MANUAL TEMPERATURE
ADJUSTMENT (the thermostat is in the OFF state).
After entering the MENU and by consecutive presses of the key the message
(High Temperature Limit) will be shown on the bottom of the screen as well as
the initial value 30.0 ºC. By pressing the key you can change this temperature
between the lower limit and the value of 30.0 ºC. By pressing the key and then
immediately the key the lower section of the screen shows the message (Low
Temperature Limit) as well as the initial temperature of 6.0 ºC. With the key
you can adjust the value between 6.0 ºC and the value of the upper limit. The
two limits define a temperature area that can be used by the user to enter the
desired temperature. The selection of the limits influences the manual
adjustment of the temperature and is independent from the operating mode of
the unit (manual, daily weekly) and does not have any influence on the
programs for daily or weekly operation.
10.OTHER MENU SETTINGS (the thermostat is in the OFF state).
All the menu settings that follow can be changed by using the same method as
described in the previous chapters. After entering the ΜΕΝU use the key to
select the required setting. The messages are shown in the bottom section of
the screen like this:
A. (Mode) OPERATION MODE. One of three operation modes can be selected:
(User) Manual mode (the symbol ΜΑΝ. is shown on the top right of the screen).
(Day) daily operation (the symbol DAY is shown on the top right of the screen.
(7 Days) weekly program (the symbol WΕΕK is shown on the top right of the
screen).
The factory default is .
Β. (Unit) TEMPERATURE UNIT.
The option are: or (Degreeή Degree Fahrenheit) and regard the display of the
temperature in ºC or ºF.
Depending on the selection, the symbol ºC or ºF are shown on the center right
of the screen.
C . (Back Light ) SCREEN ILLUMINATION.
With this setting you can turn off the screen illumination in order to
conserve battery energy. If (ΟΝ) is selected then the screen illumination will
be activated every time a key is pressed. If is selected then the screen
illumination will be deactivated
The factory default is .
D. (LED) BURNER OUTPUT INDICATOR.
This setting can deactivate the burner output indicator in order to conserve
battery energy.. If (ON) is selected then when the burner output is active the
indicator will briefly blink every second so the user has a knowledge of the
state of the thermostat from a distance.. If (OFF) is selected then the
indicator is deactivated.
Ε. (Time Out) TEMPORARY TIME FOR MANUAL OPERATION.
With this setting you can determine the time period for which the manual
temperature adjustment is valid. When the thermostat is running a daily or
weekly program and you press the keys or , either you change the temperature
through the application, then the thermostat enters briefly the manual mode
for a time period that is determined by the setting . The value of this
setting can be from 3 to 10 hours after which normal program execution is
continued. The factory default is 3 hours.
F. (Differential) DIFFERENTIAL SETTING.
This setting determines the ” temperature window ” between activation and
deactivation of the burner output. For example, if the room temperature is set
to 23.0 °C then with a differential of 0.5 °C the output to the burner will be
deactivated at 23.0 °C and will be reactivated at 22.5 °C.
The differential value can be set between 0.2 °C and 4.0 °C.
The factory default value is 0.2 °C.
G. (Heat/Cold). HEATING MODE.
The device can control only heating units (e.g. diesel
burners).
H. (Time) HOUR METER.
In this screen position you can see the total operation hours of the burner.
This value can not be altered by the keypad but can be reset if the battery is
removed. The maximum value is 9.999 hours.
I. (Factory settings) SELECTING THE FACTORY DEFAULT SETTINGS.
If for any reason there is the need to restore the thermostat to its factory
default settings then this setting will restore then if you select and press
the key .This does not affect the time and date settings.
The factory default setting is .
11. CHANGING THE BATTERY
When the screen shows the symbol the unit warns the user that the batteries
have limited energy and that they must be replaced in the next 3 weeks. To
replace the batteries simple remove the cover (Fig. 2) to expose the battery
compartment.
Remove the batteries and within 30 seconds reinsert new ones in order to avoid
a reset of the device. Should this happen it will require to adjust the time
and date again. All other setting remain unaffected. Avoid replacing the
batteries with the backlight activated, this will immediately reset the device
and the hour meter. Take care of the battery orientation and insert the new
batteries according to the graphic representation etched on the plastic base.
The reverse installation will not harm the device but it will not permit it to
operate.
The battery life time has been design to be approximately one year. Factors
that influence the battery life are prolong use of the keyboard with the
backlight active, increased temperature and humidity as well as battery
quality.
12. ANTI-ICE PROTECTION
If the room temperature in which the thermostat is installed falls below 5°C,
the unit activates the burner output irrelevant of the ON or OFF state of the
thermostat to prevent ice build up. The burner output is active for as long as
the temperature is below 5°C.
13. CLEANING THE THERMOSTAT
To clean the device use a damp cloth to remove any dust or stains from the
covers. Do not use any liquid or dissolvers that will damage the plastic
covers.
14. SCREEN MESSAGES
Following you can see a complete list of screen messages that can be seen by
consecutively pressing the key:
= Set Time =Time and date setting.
= Day = Daily program selection.
= Week = Weekly program selection.
= Mode = Operation mode selection.
= Unit = Temperature unit.
= Backlight = Screen illumination.
= LED = Burner output indication LED.
= Time out = Manual temperature time.
= High Temperature Limit = Upper limit for manual temperature
adjustment.
= Low Temperature Limit = Lower limit for manual temperature
adjustment.
= Boiler Time = Active boiler time
= Differential = Differential for burner relay.
= Absent = Absence program.
= Night = Night program.
= Heat = Heat operation mode.
= RF = Wirelless connection setting
= Factory = Factory default settings.
MISCELLANEOUS INDICATIONS
= Lock = keyboard lock.
= Unlock = unlock keyboard.
= Save = Save settings to memory.
= User = Manual program
=Degree Celsius = Celsius temperature unit.
= Degree Fahrenheit = Fahrenheit temperature unit.
= Program 1 to 10 = Program number from 1 to 10.
FACTORY DEFAULT VALUES
The following values are the factory default setting of the thermostat:
Thermostat state = Inactive (OFF)
Daily and weekly programs = Not set
Selected temperature value = 23.0°C
Normal or Night program = Normal
Temperature unit = Degrees Celsius
Screen backlight = Active (On)
Burner activation indicator = Active (On)
Presence/ Absence program = Presence
Manual selection time = 3 hours
Upper manual temperature limit = 30.0°C
Lower manual temperature limit = 6.0°C
Boiler operation time = 00 minutes (BS851/T)
Boiler state = Inactive (BS-851/T)
Operation mode = Manual (User)
Differential = 0.2° C
Absence temperature = 16.0° C
Night program temperature = 18.0° C
Heating function= Heating
Keypad state = Unlocked
DAILY PROGRAMMING EXAMPLE
Lets assume that you want to program the following temperatures and hours (programs): From 07.00 to 08.30 at 22,5°C. From 8.30 to 12.00 at 21,5°C. From 12.00 to 17.30 at 18.5°C. From 17.30 to 23.00 at 22.5°C and from 23.00 to 07.00 at 19,8°C. Note that the end hour of each program is the start hour of the next program and always the start hour of a program is at least 1 minute greater than the end hour of the previous program. It is essential to select at least 1 program per day otherwise the thermostat will operate with the factory defined temperature of 6°C. Also note that the first program is considered the program with the start hour nearest to the hour 00.00 (e.g. 07.00).
- Turn OFF the thermostat by pressing the corresponding key.
- Press continuously the key for 3 seconds The screen back light is activated . and the screen shows . Now you are in programming mode of the thermostat parameters.
- Press the key 9 times and the screen shows with the (Mode) blinking.
- Press the key and the starts to blink. With the keys and select the operation mode (Day – daily program).
- Press the key to return to the previous screen with the blinking.
- Press the key 8 times and the screen shows with the blinking. Now you are in the daily programming sub menu that has a 10 program capability.
- Press the key and the screen shows with the blinking, this shows that you are in program 1 of the daily program (the indication indicates that the current program in empty).
- Press the key and the hours digit starts to blink. With the keys and select 07.
- Press the key and the minutes digit starts to blink. With the keys and select 00.
- With the next press of the key the screen shows the temperature blinking and by using the and keys you select 22,5°C. This concludes the programming of the first program.
- Press the key and the screen shows the symbol blinking.
- Press the key and the symbol will blink. This shows that you are in the second program.
- Follow the step 8, 9 and 10 and set the time to 8.30 (which is the end time of the first program) and the temperature to 21,5°C.
- Following the steps 8, 9, 10 and 11 to adjust the remaining programs with the values 12.00/18,5°C, 17.30/22,5°C and 23.00/ 19.8°C. If by mistake you add a newprogram (ex. Ρ6), this program can’t be canceled but can be defined as a new program with a start time of 23.01 and the same temperature as Ρ5.
- Completing the daily program you can store the programmed values to the devices memory by pressing 2 times the key while the indication is blinking. The screen will show for awhile and then normal operation will continue. By activating the device with the key the daily program will start to take affect. In order for the program to execute correctly make sure you have programmed the device clock with the correct time.
WEEKLY PROGRAMING EXAMPLE.
The weekly program in general is based on the daily programming which is repeated for every day of the week independently. For the days of the week that have not been programmed, the values of the last programmed day are valid. For example, if you program only the days Monday to Wednesday, then the programming for Wednesday will be used for the days Thursday to Sunday. If you program only the days Monday, Wednesday and Thursday then for Tuesday’s program the program from Monday will be used and for the days Friday, Saturday and Sunday the program from Thursday will be used.
-
Follow the steps 1, 2, 3, and 4 of the daily programming. Select in the (Mode) section the setting and press the key .
-
Press 7 times the key and thescreen shows with the indication blinking. The symbol ΜΟ (Monday) means that you are ready to program the Monday and the symbol WEEK that you are in weekly programming mode.
-
Press the key and the screen shows . From now the procedure follows the steps 8-14 of the daily programming and you can set the required temperatures on the required time.
-
Completing the programming of the Monday program press the key and the screen shows with the indication blinking. By pressing the key , the day indicator changes to TU (Τuesday) you can repeat the steps for programming a new program for Tuesday.
The same can be done for the rest of the days of the week. -
The completion of the weekly programming can be done by pressing the key when the indicator is blinking. The screen will show the message briefly and the settings will be stored in to the devices memory.
-
Activate the device using the key. The weekly program will start to execute as defined. In order for the program to execute correctly make sure you have programmed the device clock with the correct time.
WIRELESS CONNECTION SETTING
After installing the peripheral received (BS851/R), press the programming key
(Figure 1) until the indicator POWER/STATUS (LD1) starts to blink in a rapid
manner. This shows that the unit is in programming mode. After activating the
thermostat by removing the battery separation tape, go to the selection (the
thermostat in the OFF state, prolonged press of the MENU/ENTER key and then 22
consecutive presses of the key lead us to the screen ). The number of dashes
verifies the correct connection between the two devices and also shows the
strength of the signal. The thermostat must be placed in such a position that
will allow good signal strength which means that at least 2 dashes must be
shown. If less that 2 dashes are shown the communication between the two
devices is not good and can lead to communication errors and bad operation. To
completion of the wireless installation procedure is done by pressing the
key on the thermostat and by a prolonged press of the programming key on the
peripheral until the POWER/STATUS(LD1) indicator stops to blink and remains
ON.
MOUNTING
Select mounting areas away from heating elements, door and window openings and
fireplaces and in general, away for all heat sources and away from drafts.
Mount the thermostat at a height of about 1.5 meters and on an interior wall
(The external wall have a lower temperature than the internal wall and can
affect the device).
COMMUNICATION ERROR
Errors can occur if for any reason the communication between the two devices
is disrupted. The screen of the thermostat will show the message
(Communication Error), the backlight of the screen will blink.
The interruption of the mains voltage causes the interruption of communication
between the two devices. When the voltage is restored, the peripheral device-
receiver activates the outputs according to the state before the interruption,
until the communication is automatically restored with the thermostat (maximum
delay of 6 minutes), so the outputs will change according to the new commands
that will be given.
Dimensions in mm
Installation procedure
The device shall be connected to an all-pole mains switch incorporated in the
electrical installation of the building
To install the devices BS-850/T or BS-851/T, insert a flat blade screwdriver
in the slot as shown in (Fig. 1). Press and lift the front cover.
Remove the retaining screws and remove the plastic cover that contains the
keys (Fig. 2).
Use the supplied mount accessories to mount the unit according to the diagram
of page 11.
Install the base, align it using the built in vial and tighten the screw to
secure it.
Reinstall the plastic containing the keypad with care and fasten the screws
with a maximum torque of 0,4 Nm.
To activate the device, remove the battery separation tape (Fig. 3).
Install the front cover with slight pressure and the device is ready to
operate.To install the BS-851/R, remove the front cover with a
screwdriver (Fig. 4). Mark and drill the mounting holes according to the
schematic in page 11. Mount the device using the supplied mounting accessories
(Holes A and B) as shown in Fig.5. Do the electrical connections according to
(Fig.5). Connect the phase to the L terminal and the neutral to the N
terminal, this is used to power the device. The phase cable for the outputs is
to the common of the relay contacts. In every activation, the contacts will
provide the phase to the burner. Avoid installing the phase internally (from
the L terminal to the relay common terminals) because it might cause
interferences. The outputs are not fuse protected so any short circuit will
destroy them and the device.
The cable power supply shall only be replaced by the manufacturer or his
qualified agent.
Control is intended to be used with the protection of a fuse gG, type B,
IEC60269-3-1.
Suitable for installation in non-conductive areas where conductivity can occur
temporarily due to condensation.
Warnings and safety information
WARNING HEALTH AND SAFETY INFORMATION
National safety regulations
Failure to comply with national safety regulations may result in personal
injury, discomfort, property damage and other potential hazards.
- Comply with any national regulations and comply with appropriate safety regulations
- You shall comply with any additional national regulatory informations.
Read before use to reduce the risk of personal injury, discomfort, property damage, including damage to your device and other potential hazards.
- You shall not touch the device with wet hands
- You shall not block the ventilation holes
- You shall not remove the protective parts of the device
- You shall not install your product near to liquids.
- You shall not install your product near to flammable or/and explosive atmospheres.
- You shall not install the device in dusty, smoky or near magnetic fields.
- You shall install your device to flat surfaces.
- Keep your device away from heat sources
- Keep your device at a safe distance from kids.
- Always keep your device at a safe distance away from medical devices.
- Do not attempt to repair or modify your device. Disassembling the device may cause injury to you or damage the device.
- Do not expose your product to any liquids or spray cleaners.
Observe the rules that prohibit the use of wireless technology. Your device is
designed to comply with the regulations governing radio frequency emissions,
but the use of the wireless devices may interfere and affect any other
electronic equipment.
** Risk of electric shock
Disconnect the power supply before any interference with the system
WARNING!** installation, configuration, start-up and maintenance must be
done by qualified personnel only.
Make sure that the device is installed on the wall according with the
installation instructions.
Connect the power cables according to the installation instructions. Use only
the products and accessories listed in the technical specifications for any
system expansions
Hereby, Olympia Electronics N. Lakasas – P. Arvanitidis S.A. declares that the
radio equipment type BS-850/KIT and BS-851/KIT which are consists from
BS-850/R, BS-850/T and BS-851/R, BS-851/T respectivelty are complianced with
the Directive 2014/53/EU.
The full text of the EU declaration of conformity is available on the
company’s internet site:
https://www.olympia-electronics.com/sites/default/files/940850000_17_001.pdf
https://www.olympia-electronics.com/sites/default/files/940851000_17_001.pdf
TECHNICAL CHARACTERISTICS
POWERED BY | BS-850/T – BS-851/T | BS-850/R – BS-851/R |
---|---|---|
MODEL | 2 Alkaline ΑΑ | 220 – 240V AC / 50-60Hz |
CONSUMPTION | – | 1.9VA |
MEASURING RANGE | o 0.0 99.9 °C to | – |
TEMPERATURE SELECTION RANGE | 6.0 to 30.0°C | – |
COMMUNICATION FREQUENCIES | Wireless: 869MHz / WiFi: 2.4GHz | |
MAXIMUM TRANSMITTED POWER | Wireless: 13dBm / WiFi: 16.62dBm | |
OPEN RELAY CONTACT | – | 2×5Α – 250V AC |
DEGREES OF COVER PROTECTION | ΙΡ30 (after installation/mounting according to |
manufacturer’s instructions)
TYPE 1.B ACTION| BS-850/KT No temperature drift defined
RATED IMPULSE VOLTAGE| 2500V
MAXIMUM INTENDED CLICK RATE| 5 per 60 min
EMC TEST| Tested under nominal values of current and voltage
MAXIMUM ELEMENT SENSING TEMPERATURE| 55 oC
SAMPLING PERIOD| 30 sec
OPERATION TEMPERATURE RANGE| -10 to 50°C
RELATIVE HUMIDITY| 10 – 90% RH| 10 – 95% RH
EXTERNAL DIMENSIONS| 121.5 x 27.3 x 81.3 mm| 120 x 34 x 80 mm
TYPICAL WEIGHT| 175 gr. (with batteries)| 200 gr.
GUARANTEE| 2 years
WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies each product. This warranty ceases to exist if the buyer does not follow the technical instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty period is valid. Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.
HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>