mr steam MS-90E iSteam3 Generator Instruction Manual
- June 12, 2024
- Mr.Steam
Table of Contents
MS-90E iSteam3 Generator
Product Information:
This product is an electrical steam generator designed for use
in steam rooms. It is manufactured by Sussman-Automatic
Corporation. The generator produces steam and elevated temperatures
for a steam bathing experience. The user manual provides important
safety instructions and guidelines to ensure safe and efficient
installation and operation of the generator.
Product Usage Instructions:
-
Read and Follow All Instructions: It is
important to thoroughly read and understand all instructions
provided in the user manual before installing and using the steam
generator. -
Restrict Usage to Age 16 and Above: Do not
allow children under the age of 16 to use the steambath. -
Handle Steam with Caution: Steam is hot and
can cause injury or even death if used improperly. Take note of all
warnings in the manual regarding steam rooms. -
Prevent Slipping: The wet surfaces of steam
enclosures may be slippery. Exercise caution when entering or
leaving the steam room. -
Avoid Steamhead Contact: The steam head can
become very hot. Do not touch the steamhead or get too close to the
steam emitted from it. -
Moderate Usage Time: Prolonged use of the
steam system can raise the body’s internal temperature excessively,
leading to hyperthermia. Limit steam usage to 10-15 minutes until
you are familiar with your body’s reaction. -
Pregnancy Precautions: Excessive temperatures
pose a risk of fetal damage during early pregnancy. Consult a
physician for correct exposure guidelines if you are pregnant or
possibly pregnant. -
Consult a Physician: Obese individuals, those
with a history of heart disease, low or high blood pressure,
circulatory system problems, or diabetes should consult a physician
before using the steambath. -
Medication Considerations: If you are using
medication, consult a physician before using the steambath as some
medications may induce drowsiness or affect heart rate, blood
pressure, and circulation. -
Be Aware of Risks: Failure to perceive heat,
recognize the need to exit the steambath, unawareness of impending
risk, fetal damage in pregnant women, physical inability to exit
the steambath, and unconsciousness are potential risks associated
with steam usage. -
Avoid Alcohol, Drugs, and Medication: The use
of alcohol, drugs, or medication greatly increases the risk of
hyperthermia. It is advised to abstain from these substances before
using the steambath.
Please refer to the user manual for additional information on
operating instructions, system log, care tips, safety guidelines,
and warranty details.
Installation, Operation & Maintenance Manual
iSteam®3 Control
. mr steam® Feel Good Inc.
READ ME FIRST!
! WARNING As you follow these instruc-
tions, you will notice warning and caution symbols. This blocked information
is important for the safe and efficient installation and operation of this
generator. These are types of potential hazards that may occur during
installation and operation:
! WARNING Indicates a potentially
hazardous situation, which, if not avoided, could result in death or serious
injury.
! CAUTION Indicates a potentially
hazardous situation, which, if not avoided may result in minor or moderate
injury or product damage.
IMPORTANT NOTE: This highlights information that is especially relevant to a
problem-free installation.
All information in these instructions is based on the latest product
information available at the time of publication. Sussman-Automatic
Corporation reserves the right to make changes at any time without notice.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS
2. ! WARNING Do not permit children under
the age of 16 to use this steambath.
3. ! WARNING Steam is hot and can cause injury
or death if improperly used. Steam rooms contain steam and elevated
temperatures. Please read and observe all warnings in this manual before
installing or using a steam room.
4. ! WARNING To reduce the risk of injury:
A. The wet surfaces of steam enclosures may be slippery. Use care when
entering or leaving.
B. The steam head is hot. Do not touch the steamhead and avoid the steam near
the steamhead.
C. Prolonged use of the steam system can raise excessively the internal human
body temperature and impair the body’s ability to regulate its internal
temperature (hyperthermia). Limit your use of steam to 10-15 minutes until you
are certain of your body’s reaction.
D. Excessive temperatures have a high potential for causing fetal damage
during the early months of pregnancy. Pregnancy or possibly pregnant women
should consult a physician regarding correct exposure.
E. Obese persons and persons with a history of heart disease, low or high
blood pressure, circulatory system problems, or diabetes should consult a
physician before using a steambath.
F. Persons using medication should consult a physician before using a
steambath since some medication may induce drowsiness while other medications
may affect heart rate, blood pressure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat; b) Failure to recognize the need to exit the steambath; c) Unawareness of impending risk; d) Fetal damage in pregnant women; e) Physical inability to exit the steambath; and f) Unconsciousness.
! WARNING
The use of alcohol, drugs, or medication can greatly increase the risk of
hyperthermia.
51/4″
iSteam3 Template for the f inished wall cut-out
39/16″
2
Table of Contents:
Important Safety Instructions…………………… 2
INSTALLER INFORMATION Installation Template …………………………….. 2 Box Content
…………………………………………. 3 Dimensional Information ………………………… 3 Before
Installing…………………………………….. 4 Locating the Control………………………………. 5 Installation
with Rough-In Box………………. 5-6 Installation without Rough-In Box ……………. 6
iSteam®3 Installation …………………………… 7-8
USER/HOMEOWNER INFORMATION Operating Instructions
Stand-By, Start, Dashboard, Set Timer …………….9 Set Temperature, User Settings
……………….. 10 ChromaSteam®…………………………………… 10 AudioSteam, AromaSteam ……………………….11
Optional Accessories ……………………………… 11 Settngs: System Setting, Date and Time ……
12
AutoStart, Passcode, About ………. 13 System Log …………………………… 13 Care Tips, Safety
& Operating Info ………… 14 Warranty …………………………………………….. 14
Dimensional Information
6 1/8″
Box Contents:
· iSteam®3 Control · Control Cable (30 ft.) · Steamhead · Tube of Silicone
Sealant · Owner’s Manual · Rough-In Box
13/8″
4 1/ 2″
10:06 AM
97 F 12:16 PM
START START
ACCESSORIES
SETTINGS
Pigtail
(81/2″)
Wall location for optional surface mount
Wall location for flush mount
3
mr.steam __®_____I_NS_T_A_L_L_E_RI_N_FO_R_M__ATION
Before Installing
! WARNING To avoid unintentional steambath op-
eration, do not locate the control where other controls, accessories, shower
heads, valves, body sprays or similar within the shower could cause confusion
or interfere with the MrSteam control’s intended use and function.
! CAUTION
· To prevent possible injury Do Not use the iSteam®3 control without reading
and understanding the MrSteam steam generator Installation and Operation
Manual.
· A peel and stick warning sticker is provided in the MrSteam steam generator
Installation, Operation and Maintenance Manual. This manual is provided with
every steam generator. The warning sticker must be read and permanently
affixed in a conspicuous location near the steam room. Failure to read and
affix this warning sticker in a conspicuous location may result in serious
injury or death. Please call MrSteam at 800 767-8326 for a free replacement or
if you have any questions regarding the warning sticker.
Not actual size
! CAUTION Do not route iSteam3 control wiring in-
side conduit together with power lines or close to hot water or steam piping.
Doing so may result in an inoperative or hazardous installation. Do not alter
or modify any Mr. Steam products including the steam generator or iSteam3
control. Doing so may result in an inoperative or hazardous installation and
will void the warranty.
IMPORTANT NOTES:
· The iSteam3 Control is designed to be flush mounted. However, the control
may be surface mounted when conditions permit. Consult a MrSteam Customer
Service or Technical Service representative to determine if the iSteam3
control can be surface mounted.
· Turn power to the steam generator OFF before connecting the control to the
generator. Failure to turn the power off will result in an inoperable control.
· Do not operate the iSteam3 control with other than a MrSteam iSteam3
compatible steam generator. MrSteam residential steam generators with serial
numbers lower than 1174000, or any other brand of steam generator are not to
be operated with iSteam3 controls. Doing so may result in an inoperative
installation. If your generator’s serial number is lower than 1174000 contact
MrSteam Technical Service for upgrade options and components to enable your
steam generator to function with iSteam3.
· This document contains important safety, operation and maintenance
information. Leave this document with the homeowner. Do not discard this
document.
· Discontinue use of the steam generator or control if the steam generator is
damaged or otherwise not functioning properly. Doing so may result in an
inoperative or hazardous installation
· Refer to the Steambath Generator Installation, Operation and Maintenance
Manual for locating and installing the steamhead.
· If an iSteam3 control is installed outside the steam room a Remote Temperature Probe (PN MSTS) must be installed inside the steam room per installation instructions supplied with the Remote Temperature Probe. Failure to install according to instructions will result in an inoperative control and overheating of the steam room.
! WARNING Do Not alter or modify any MrSteam
products. Doing so may result in an inoperable or hazardous installation and
will void the warranty.
4
mr.steam __®____I_N_S_T_AL_L_E_RINF_O_R__M_AT_IO_N
Locating the Control
Determine the desired installation location of the control. The iSteam®3
controls are designed to be installed inside or outside the steam room as a
matter of personal preference. If the control is installed inside the steam
room: · Locate the control 4-5 feet above the floor near the bather seating
area. · The control features an integral temperature sensor. Locate the
control in a
location representative of the desired steam bathing temperatures. Do not
locate the control above or near the steam head or direct steam emissions. ·
Locate the control on a vertical wall. · The control cable is 30 feet. Insure
that the control and steam generator are located accordingly.
IMPORTANT NOTES: · If required, contact MrSteam to purchase an optional 60′
iSteam3
control cable part number 104117-60. · If the control is installed outside the
steam room a Remote Temperature
Probe Part Number MSTS must be installed inside the steam room. Refer to the
MSTS installation manual before installing the control. · Insure MrSteam steam
generator is iSteam3 compatible and has a serial number 1174000 or higher.
Installation with Optional Rough-In Box
A rough-in box is supplied with iSteam3 for new construction. The rough -in
box will allow precise location of the iSteam3 control and provide a secure
and easily identifiable place for the cable while the steam room is being
constructed.
STEP 1 Take the rough-in box out of the package. Remove the two screws (1a )
and place them in the top and bottom wings of the rough-in box (1b).
STEP 2 Select a KNOCK-OUT (2a) to route the control cable into the box.
STEP 3 Line up the two TABS (3a) on the right side of the box against a stud.
These TABS help locate the box to sit PROUD of the stud (3b).
STEP 4 SCREW (4a) the two supplied screws into the stud.
STEP 5 Route the CONTROL CABLE (5a) through the back of the rough-in box and
clip it under one of the TABS (5b) that previously held the screws. The two
ends of the control cable are the same.
IMPORTANT NOTE: The control cable should be run in a dedicated 1″ conduit to
facilitate installation and service.
5
1b 1a
1b
2a 3b
3a
4a
4a 5b 5a
mr.steam __®____I_N_S_T_AL_L_E_RINF_O_R__M_AT_IO_N
Installation with Optional Rough-In Box (cont.)
IMPORTANT NOTE: Be careful not to strain, staple, pinch or
otherwise damage the cables. Route cables as required to permit
replacement. Do not route cables inside conduit together with power
7
lines or close to hot water or steam piping.
Rough-In box used as a guide to cut out the opening.
STEP 6 Use the rough-in box as a guide to cut out the (39/16″ x 51/4″) opening
in the wall.
Finish the iSteam®3 installation using the instructions on page 7.
Installation without Rough-In Box
STEP 1 Make a 39/16″ x 51/4″ cut-out in the desired location using the
template provided on page 2 of this manual.
STEP 2 Route the control cable from the wall cutout to the steam generator.
Connect one end of the cable to the steam generator connector. The two ends of
the control cable are the same.
IMPORTANT NOTE: Be careful not to strain, staple, pinch or otherwise damage
the control cable. Route cable as required to permit replacement. Do not route
cable inside conduit together with power lines or close to hot water or steam
piping. Finish the iSteam3 installation using the instructions on page 7.
51/4″ 39/16″
6
mr.steam
__®____I_N_S_T_AL_L_E_RINF_O_R__M_AT_IO_N
Installation Instructions for iSteam®3
STEP 1 PLUG the 30′ control cable into the iSteam3 control pigtail (1a).
Turn the generator on and test the control to verify correct connection. With
proper function, proceed to Step 2.
! CAUTION Do not force or twist cable ends together.
Forcing or twisting cable ends may damage the connectors.
Control Cable
1a
97 F 12:16 PM
START
Control Pigtail
Steam Generator
For illustrative purposes only.
7
mr.steam __®____I_N_S_T_AL_L_E_RINF_O_R__M_AT_IO_N
Installation Instructions for iSteam®3 (cont.)
STEP 2
Peel the double stick adhesive off the back of the iSteam3 control (2a). Apply
a bead of silicone around the rear of the iSteam3 control to create a moisture
seal (2b). Carefully feed the cables into the rough-in box and secure the
control to the wall. Care must be taken to not pinch the cables. Ensure the
control is level.
IMPORTANT NOTE: The control must be installed with the arrow on the Peel-Off
screen protector facing up. If the Peel-Off screen protector has been removed
see the drawing in Step 2b for the proper orientation. The control display can
be flipped 180 degrees in the settings menu if installed upside down.
NOTE: The silicone supplied by MrSteam can be used to meet a variety of
sealing and gasketing. It cures to silicone rubber and adheres to glass, wood,
metal, porcelain, ceramic tile, painted surfaces, many plastics and rubber.
Surfaces must be clean and dry. Apply thin layer of product. Fit together and
support if necessary. Allow excess material to cure, then trim with a sharp
blade. Sealant “skins” in 5 minutes, dries to touch in 1 hour. Fully cures and
bonds in 24 hrs.
IMPORTANT NOTE: Do not apply excessive amounts of silicone. Do not apply
silicone to any other parts of the control including the adhesive gasket.
Insure the mounting surface is clean and dry as required for good adhesion.
Hold the control with the arrow on the screen protector facing up and press
the control against the wall until the adhesive sticks and holds firmly.
Control may have to be supported or secured until the silicone has cured for
24 hours.
2a
2b
Before use, remove and discard the peeloff screen protector. 2c
97 F 12:16 PM START
This End Up This End Up
8
mr.steam®
HOMEOWNER SECTION
READ ME FIRST!
! WARNING As you follow these instruc-
tions, you will notice warning and caution symbols. This blocked information
is important for the safe and efficient installation and operation of this
generator. These are types of potential hazards that may occur during
installation and operation:
! WARNING Indicates a potentially
hazardous situation, which, if not avoided, could result in death or serious
injury.
! CAUTION Indicates a potentially
hazardous situation, which, if not avoided may result in minor or moderate
injury or product damage.
IMPORTANT NOTE: This highlights information that is especially relevant to a
problem-free installation.
All information in these instructions is based on the latest product
information available at the time of publication. Sussman-Automatic
Corporation reserves the right to make changes at any time without notice.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS
2. ! WARNING Do not permit children under
the age of 16 to use this steambath.
3. ! WARNING Steam is hot and can cause injury
or death if improperly used. Steam rooms contain steam and elevated
temperatures. Please read and observe all warnings in this manual before
installing or using a steam room.
4. ! WARNING To reduce the risk of injury:
A. The wet surfaces of steam enclosures may be slippery. Use care when
entering or leaving.
B. The steam head is hot. Do not touch the steamhead and avoid the steam near
the steamhead.
C. Prolonged use of the steam system can raise excessively the internal human
body temperature and impair the body’s ability to regulate its internal
temperature (hyperthermia). Limit your use of steam to 10-15 minutes until you
are certain of your body’s reaction.
D. Excessive temperatures have a high potential for causing fetal damage
during the early months of pregnancy. Pregnancy or possibly pregnant women
should consult a physician regarding correct exposure.
E. Obese persons and persons with a history of heart disease, low or high
blood pressure, circulatory system problems, or diabetes should consult a
physician before using a steambath.
F. Persons using medication should consult a physician before using a
steambath since some medication may induce drowsiness while other medications
may affect heart rate, blood pressure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA occurs when the internal temperature of the body reaches a level
several degrees above the normal body temperature of 98.6° F. The symptoms of
hyperthermia include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia
include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath; and
f) Unconsciousness.
! WARNING The use of alcohol, drugs,
or medication can greatly increase the risk of hyperthermia.
! WARNING The peel and stick
warning label located in the steam bath generator manual is an essential part
of providing a safe environment for steam room users. The peel and stick
warning label must be applied to the wall of the shower or steam enclosure, at
a point that is visible to all users. Failure to install this sticker may
result in serious injury or death.
The location where this owner’s manual is kept shall be written in the space
provided on the label using permanent ink.
For a replacement warning label contact MrSteam customer service at
1-800-76-STEAM or hello@mrsteam.com
Not actual size.
9
mr.steam __®_____U__S_ER/_H_OME_O_WNE_RINF_O_R__M_AT_IO_N
Operating Instructions
! WARNING Set the steam bathing duration and
temperature according to personal preference, however it is highly recommended
to begin steam bathing at a low temperature setting to gauge comfort and
safety levels. Set the duration at 10 minutes max. to gauge comfort and safety
levels. This will allow the steam generator to heat up and begin producing
steam.
Touch anywhere to wake up control
101 F 12:16 PM
Stand-By Screen
Touch anywhere on the clock screen to enter the Start Screen.
MONDAY
April 28th, 2016
Touch anywhere to operate steam generator
Start Screen
Press the START button to turn the steam generator ON and to display the
Dashboard screen. Steam will begin to flow a few minutes after the START
button is pressed. The time required for the steam room to reach steam bathing
temperatures depends on the steam room construction and steam generator
specifications.
AudioSteam Main Start Screen
System Settings ChromaSteam
97 F 12:16 PM
START
Touch to Start
Dashboard Screen
The Dashboard displays key steam bathing features and optional accessories in
one convenient screen. The key features include TIME, TEMPERATURE and USER
settings. The optional accessories include the ChromaSteam®, AromaSteam and
AudioSteam.
Set Timer Screen
Press the TIMER button on the Dashboard to access the SET TIMER screen. Swipe
your finger up/down to select the desired time (1-60 minutes). The control
will turn off when the steambath session times out. Then the START screen will
be displayed.
10
STOP
40min 101 oF
101 F 12:16 PM
AromaSteam
Adjust Timer Adjust Set Point Temperature Save/Recall User Settings
101 F 12:16 PM
40 35 30 MIN 25 20
Swipe Up and Down
mr.steam __®_____U__S_ER/_H_OME_O_WNE_RINF_O_R__M_AT_IO_N
Set Temperature Screen
Press the TEMPERATURE button on the Dashboard to access the SET TEMPERATURE
screen.
The control is preset and will display a temperature setting of 110°F (default
setting). Swipe your finger up and down to adjust the desired temperature (80
– 120 F) in one degree increments.
97 98 99oF 100 101
101 F 12:16 PM
Swipe Up and Down
User Settings
Press the SAVE/RECALL user settings button. To save the settings press the
SAVE CURRENT SETTINGS button. A keyboard will pop up where the user name can
be entered. To recall the user settings press the user’s name. To remove the
settings press the delete icon. A maximum of 8 user settings can be saved.
Press to recall user settings
Press to delete user
101 F 12:16 PM
Erica John James Save Current Settings
Press to save the current settings. A keyboard will open for the user to enter
their name. A maximum of 8 users can be saved.
ChromaSteam®
The ChromaSteam is an optional accessory that activates colored lights in the
steam room. Press the CHROMA button to turn it ON. When ChromaSteam is on,
press the CHROMA button to turn it off. Press the ChromaSteam Dashboard button
to bring up the color wheel. Touch anywhere on the wheel to select that color.
To adjust the brightness, use the slider on the bottom of the ChromaSteam
Dashboard. The slider will change color to show current color selection.
(Note: Brightness cannot be adjusted in automatic color changing modes) Press
the Discrete Color Selection button to pick a preselected list of colors, have
white light, or slow or fast changing color modes.
Press to select discrete colors
11
97 F 12:16 PM
CHROMA
Press to turn ChromaSteam On/Off
Touch wheel to select color
97 F 12:16 PM
CHROMA
ChromaSteam On/Off Screen
ChromaSteam Dashboard
Discrete Color Selection
Slide to adjust brightness
White Red Purple Blue Green
97 F 12:16 PM
Swipe Up and Down
mr.steam __®_____U__S_ER/_H_OME_O_WNE_RINF_O_R__M_AT_IO_N
AudioSteam
97 F 12:16 PM
Press the music icon screen.
to access the AudioSteam
Press the MUSIC button to turn on AudioSteam. When AudioSteam is ON, pressing the MUSIC button will turn it OFF.
Press the AudioSteam Dashboard button to control the music. When paired to a Bluetooth® device, iSteam®3 will display the song title, artist and album name. If listening to the FM radio, the station number will be shown. This space is blank if playing music from a hard wired source.
Mute
Previous Track or scan backwards when in FM mode
Slide to adjust volume
Play/Pause (Bluetooth only)
Next Track or scan backwards when in FM mode
If you are using a Bluetooth audio source, it must be connected for functions
to work. Please refer to the Bluetooth pairing instructions in the AudioSteam
IOM.
Press the Source button to select hardwired AUX source, Bluetooth source or
the FM radio. To unpair the current connected Bluetooth device, press the
DISCONNECT button.
MUSIC
Press to turn AudioSteam ON/OFF
SONG TITLE Artist
Album Name
97 F 12:16 PM
AudioSteam On/Off Screen Music Dashboard Source Button
Mute
Previous Track
Play/Pause
Net Track
or scan backwards (Bluetooth only) or scan backwards
when in FM mode
when in FM mode
Press to select source
97 F 12:16 PM
AUX
Bluetooth
Disconnect
Radio
Press to disconnect current paired Bluetooth device
AromaSteam
The AromaSteam is optional accessory that automatically infuses aromatic oils
into the steam flow. Press the AromaSteam icon to bring up the AromaSteam
Dashboard. Press the AROMA button to turn it ON.
The AromaSteam turns OFF automatically when the steam generator stops.
Press the AROMA button to turn it OFF during a steam session.
After the steam session has ended the AudioSteam and ChromaSteam® will remain
ON. They can be turned OFF individually by navigating to each’s power button,
or both can be turned OFF by pressing the OFF icon that appears on the START
screen.
12
101 F 12:16 PM
AROMA
Press to turn AromaSteam ON/OFF
97 F 12:16 PM
START
After steam session is completed press to turn all accessories off
mr.steam __®_____U__S_ER/_H_OME_O_WNE_RINF_O_R__M_AT_IO_N
Settings Screen
The Setting Screen allows access to less frequently used screens.
System Settings Date & Time AutoStart Passcode About
97 F 12:16 PM
System Setting
Scroll through the System Settings list and select which to adjust.
Temperature Units. Adjust between °F and °C
Flip Screen. Rotates the screen 180° in case the control was installed upside
down
User Interface Color: Toggle between a white and black background
Brightness: Adjust the screen brightness
Language: Change the language used in the user interface
Once the setting is changed, press the System Setting button in the menu on
the right to exit
Temperature Units Flip Screen User Interface Color Brightness Language
97 F 12:16 PM
System Setting
Date and Time
Scroll up and down to select the date and time. Once selected, press the Set
Date and Time button in the menu on the right to exit
January
13
Febuary
14
March
15
April
16
97 F 12:16 PM
2014 2015 2016 2017
Set Date and Time
January
13
Febuary
14
March
15
April
16
97 F 12:16 PM
2014 2015 2016 2017
13
mr.steam __®_____U__S_ER/_H_OMI_N_ES_OT_AWLN_L_E_RINF_O_R__M_AT_IO_N
AutoStart
! WARNING AutoStart will automatically turn the steam generator on at your
preset time. Activating the steam in an occupied room may subject persons to
the hazards described in this manual. Only activate the steambath if the steam
room door is closed. Activating or using the steambath with an open door may
cause property damage or injury to persons outside of the steam bath.
The AutoStart feature can be used to turn on the steambath at a predetermined
time. Select the day(s) of the week and the time of day you would like to turn
the steam bath on.
When AutoStart starts your steambath it will allow the steambath to run for
only 10 minutes. To continue steam bathing press the continue button. If the
continue button is pressed, AutoStart will remain active for the next
scheduled start time.
To stop the steam bath press the STOP button.
If the STOP button or 10 minute time out turns the steam generator off,
AutoStart will automatically be deactivated.
To create an AutoStart time, press the + icon. Select the start time to
adjust the day and time for AutoStart. A maximum of 8 start times can be
programmed. To delete a start time, press the trash can icon.
To turn AutoStart ON, press the AutoStart button above the start time list.
Turn AutoStart ON or OFF
77 F 12:16 PM
AUTOSTART
Day Every day
Time 12:00am
Create a new AutoStart Delete start time time (max. of 8)
Passcode
The Passcode feature can help prevent unintentional use of the steambath.
Please refer to the steam generator Installation, Operation and Maintenance
manual before using the steambath. The Passcode feature cannot insure
unintentional use of the steambath.
To turn the Passcode lock ON or OFF, press the lock icon.
Enter a 4 digit passcode using the keypad. Press the entire button to SAVE the
passcode. The next time the iSteam3 control is turned on the user will be
prompted to enter the passcode. Press the Back button to exit without storing
the passcode lock.
If you forget your passcode, power should be turned off at the circuit
breaker. After 1 minute turn the breaker back on. The passcode lock will
automatically be turned OFF.
4321
Enter a 4 digits code to lock the keypad. The same code will be used to unlock
it.
About Screen
Press ABOUT to view the accessories connected to the steam generator.
System Log
Press SYSTEM LOG to view an error log created by the steam generator.
! WARNING To prevent injury and/or equipment damage all troubleshooting is to be performed by qualified licensed electrician or plumber. Contact MrSteam technical support at 1-800-727-8326 (East coast) or 1-800-727-8326 (West coast) in the event that iSteam®3 displays an error code.
14
mr.steam
__®_____U__S_ER/_H_OME_O_WNE_RINF_O_R__M_AT_IO_N
Care Tips
Use only mild soap and water on a soft cloth to clean the control. Do not use
abrasive cleansers.
Safety and Operating Information
! WARNING A peel and stick warning sticker is provided
in the MrSteam steam generator Installation, Operation and Maintenance Manual.
This manual is provided with every steam generator. The warning sticker must
be read and permanently affixed in a conspicuous location near the steam room.
Failure to read and affix this warning sticker in a conspicuous location may
result in serious injury or death. Please call MrSteam at 800 767-8326 for a
free replacement or if you have any questions regarding the warning sticker.
! WARNING Set the steam bathing duration and tempera-
ture according to personal preference, however it is highly recommended to
begin steam bathing at a low temperature setting to gauge comfort and safety
levels. Set the duration at 10 minutes max. to gauge comfort and safety
levels. This will allow the steam generator to heat up and begin producing
steam.
! CAUTION Do not use any iSteam®3 control without
reading and understanding the MrSteam steam generator Installation and
Operation Manual (PN 100472). Failure to read and understand these
instructions may result in an inoperative or hazardous installation.
! CAUTION If an iSteam3 control is installed outside the
steam room a Remote Temperature Probe (PN MSTS) must be installed inside the
steam room per installation instructions supplied with the Remote Temperature
Probe. Failure to install according to instructions will result in an
inoperative control and overheating of the steam room.
Warranty To view or download the MrSteam Control Warranty
and register your product go to: blog.mrsteam.com/wr
15
mr.steam®
Feel Good Inc.®
www.mrsteam.com
Products, information and specifications are subject to change without notice.
For more information call Sales & Support at 1.800.76.STEAM (East Coast) or
1.800.72.STEAM (West Coast) for more information.
mr.steam® Sussman-Automatic Corporation® I hello@mrsteam.com I www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 I 9410 S. La Cienega Blvd.
Inglewood CA 90301 1 800 767 8326 FAX: 718 472 3256 I 1 800 72 STEAM FAX: 310
216 2944
2017 © Sussman-Automatic Corporation I MrSteam and des., A Lifetime of
Pleasure, AirTempo, AromaFlo, AudioWizard, AutoFlush, Butler Package,
ChromaSteam, Clean Steam…Every Time, Club Therapy, Digital 1, Express Steam,
Feel Good Inc., From Bathroom to Spa, iButler, iGenie, iSizing, iSteam, Making
Wellness a Way of Life, Music Therapy, Spa Package, Steam on Demand,
Steam@Home, iTempo, iTempo/Plus, SmartSizing, SteamStart, SteamStop,
SteamTherapy, Sussman, Tala, Bath & Body Therapy, The Intelligent Steambath,
Valet Package, Virtual Spa System, Voice Genie and Voice Wizard are registered
trademarks of Sussman-Automatic Corporation.
PUR 100514 REV 7.17