Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.

Function / Application

This inspection camera features a micro-camera that sends color video images to the LCD so that areas that are difficult to access (cavities, shafts, masonry, or inside cars, for example) can be checked.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • The structure of the device must not be modified in any way.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak. ist.
  • When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
  • The LCD unit must not be immersed in water. The base unit must not come in contact with liquids.
  • The camera head is not acid-resistant or fireproof.
  • It is absolutely vital to ensure that the VideoScope One does not come into contact with chemicals, voltage, moving or hot objects. This can damage the device and put its user at risk of serious injury.
  • The VideoScope One must not be used for medical examinations / examining people.
  • Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.
  • The unit is not suitable for taking measurements close to dangerous voltages. Therefore always make sure that conductive parts are at zero potential when carrying out measurements in the vicinity of electrical systems. Safe isolation from the power supply and precautions to prevent systems being switched on again must be ensured by implementing suitable measures.

Safety instructions

Using artificial, optical emission (OStrV)
LED outlet
Laserliner 082 252A Inspection Camera Probe Diameter - figure
2

  • The device works with LEDs of risk group RG 0 (exempt, no risk) in accordance with the latest versions of applicable standards relating to photobiological safety (EN  62471:2008-09ff / IEC/TR 62471:2006-07ff).
  • When used for the intended purpose and under reasonably foreseeable conditions, the accessible radiation of the LEDs is safe for the human eye and skin.

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations, or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

Laserliner 082 252A Inspection Camera Probe Diameter - figure
3

1 LCD
2 ON/OFF
3 LED lighting
4 Image rotation| 5 Zoom
6 external monitor
7 socket
8 Operation indicator| 9 Battery compartment
10 Camera head
11 LED
12 Lense
---|---|---

LC-Display

Laserliner 082 252A Inspection Camera Probe Diameter - figure
4 a Battery status
b Zoom
c Intensity of LED lighting (5 brightness levels)

Functions during transmission of images
Line up the camera head-on the flex cable and move it to the required position. If lighting conditions are poor, switch on the LED lighting. Zoom in on distant or small objects.  The manual image rotation function enables the image to be rotated by 180° on the monitor.

  1. Inserting batteries
    Open the battery compartment and insert batteries (4 x typ AA) according to the symbols. Be sure to pay attention to polarity.

  2. ON/OFFLaserliner 082 252A Inspection Camera Probe Diameter - figure 6

  3. Zoom (5 steps)
    Laserliner 082 252A Inspection Camera Probe Diameter - figure
7

  4. Brightness (5 steps)
    Laserliner 082 252A Inspection Camera Probe Diameter - figure
8

  5. Image rotation
    Laserliner 082 252A Inspection Camera Probe Diameter - figure
99
    Laserliner 082 252A Inspection Camera Probe Diameter - figure
10

From the original image
1x = Horizontal mirroring
2x = Original image

Camera head / Focus

The VideoScope One delivers sharp images in a range between 3 and 7 cm from the camera head.

Laserliner 082 252A Inspection Camera Probe Diameter - figure
11

Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents, and solvents. Remove the battery(ies) before storing it for longer periods. Store the device in a clean and dry place.

Camera head diameter 0 9 mm
Screen type 2,7″ TFT color display
Display resolution 320 x 240 Pixel
Camera probe protection class IP 68
Camera resolution 320 x 240 Pixel
Connections RCA video output
Field of view (FOV) 530
Depth of focus (DOF) 3 … 7 cm
Probe length 1,5 m
Power supply 4 x 1,5V LR6 (AA)
Operating time approx. 4 hours
Operating conditions 0°C … 45°C, max. humidity 20 … 85% RH, no

condensation, max. working altitude 4000 m above sea level
Storage conditions| -10°C … 60°C, max. humidity 80% RH
Dimensions (W x H x D)| 100 x 200 x 130 mm (without flexible tubing)
Weight| 510 g (incl. batteries)

EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info

VideoScope One

SERVICE Umarex GmbH & Co KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
[email protected]
Umarex GmbH & Co KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals