mr steam 104040MB Aroma Designer 3 W Steamhead with AromaTherapy Reservoir Instructions
- June 9, 2024
- Mr.Steam
Table of Contents
STEAM HEAD
INSTALLATION INSTRUCTIONS
104040MB Aroma Designer 3 W Steamhead with AromaTherapy Reservoir
IMPORTANT: See the Installation and Operation Manual provided with the steam generator for additional important steamhead & control installation and operation information.
Installation:
Steam Head ( 1⁄2″ NPT)
CAUTION
INSTALLER: Because the steam head and direct steam emissions are very
hot, locate the steam head where incidental contact by bather with the steam
head or direct steam emission cannot occur.
STEP 1 Locate steam head 6-12 inches above floor, except for:
- Tub/shower enclosures, install 6 inches above tub top edge.
- For enclosures with acrylic or other non-heat resistant flooring install Acrylic Shield Part Number MS-103938.
- To prevent door seals from deteriorating do not locate the steam head where direct steam emission would contact door seals.
STEP 2 Install steamhead with the oil well facing up as shown. Hand
tightening is sufficient when teflon or equal pipe thread sealing compound is
used.
IMPORTANT NOTE: to preserve steam head finish, do not use wrench or other
tools to tighten. DO NOT use abrasive cleansers or chemicals. Use only water
with mild soap and a non-abrasive sponge.
CAUTION
Consult with supplier of acrylic, fiberglass and other non-heat resistant
enclosures for recommended steamhead location. Use Acrylic Shield part number
MS-103938. See instructions provided with steam shield.
STEP 3 Secure a bronze drop ear fitting to a header and run a 1/2″ copper
steamline from the steam generator to the drop ear fitting.
Install a temporary nipple (6″ or longer)in the drop ear fitting to locate the
steamhead after the wall is finished. STEP 4 After the wall has been
finished, mark on the nipple where the surface of the wall is. Remove the
nipple and measure the portion that was in the wall (the end to your mark).
Subtract 1⁄4 ” from that dimension and select a brass nipple of that length to
finish the installation. STEP 5 Wrap teflon tape around the threads of the
new nipple and screw the nipple into the steamhead. Do not use wrenches or
tools which would damage the steamhead’s finish. Wrap teflon tape around the
threads of the nipple and screw the nipple and steamhead assembly you just
made into the drop ear fitting in the wall. The steamhead should be flush with
the wall and the well must be facing up.
All drawings are for illustrative purposes only
****hello@mrsteam.com
www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472
3256
9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216
2944
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>