BEGA 22444 Ceiling Wall Pillar Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 22444 Ceiling Wall Pillar Luminaire
Dimension
Application
Unshielded ceiling, wall and pillar luminaire with high protection class.
A luminaire made of aluminium alloy and impact resistant crystal glass with
light diffusing structures.
Product description
Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Crystal glass, white inside
2 mounting holes ø 5.5mm
Distance apart 144mm
2 cable entries for through-wiring of mains
supply cable ø 7-10.5mm
Connecting terminal and
earth conductor terminal 2.5@
Lamp holder E 27
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK08
Protection against mechanical
impacts < 5 joule
– Safety mark
– Conformity mark
Weight: 1.8 kg
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Lamp
Luminaire with screw base E 27
Lamp output max. 60 W
This product contains light sources of energy efficiency classes E, F
Supplied lamp
BEGA LED lamp 13584
LED Retrofit 7 W · 805 lm · 3000 K
Luminaire efficiency: 69%
Additional BEGA LED lamps are available for this luminaire:
13 586 LED 7 W · 805 lm · 3000 K dimmable
13 588 LED 8 W · 1055 lm · 3000 K
13 590 LED 12 W · 1400 lm · 3000 K
13 592 LED 12 W · 1400 lm · 3000 K dimmable
Radio-controlled version (Zigbee 3.0):
13 555 LED 9 W · 805 lm · 2700 K dimmable
13 556 LED 9 W · 805 lm · 2700-6500 K dimmable · tunable white
13 557 LED 9.5 W · 805 lm · 2700-6500 K dimmable · tunable white · RGBW
Detailed technical and lighting data for the lamps can be found in the data sheets on our website.
Relamping · Maintenance
Disconnect the electrical installation.
Open the luminaire and clean.
Use only solvent-free cleaning agents. Change the lamp.
Check the gasket and replace, if necessary.
Close the luminaire.
For cleaning, do not use high pressure cleaners.
Spares
Spare glass 11 002 814 11
LED lamp 3000K 13 584
Lampholder 63 000 355
Gasket 83 001 831
Customers Support
BEGA Gantenbrink-Leuchten KG
Postfach 3160
58689 Menden
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>