TESLA 349731 Smart Cat Toilet User Manual
- June 6, 2024
- Tesla
Table of Contents
TESLA 349731 Smart Cat Toilet
MATTERS NEED ATTENTION
The product should be placed indoors or used in a similar indoor
environment:
It should be placed on the horizontal hard ground or wood floor (the
supporting feet should touch the placing surface evenly), not on the carpet,
which will affect the sensor precision; When carrying the product without
packaging, please do not drag it away on the floor and handle it lightly,
otherwise it will damage the weighing sensor; The cat‘s weight should be
between 0,7kg (« 2 months old) and 10kg, otherwise the feedback of weight
accuracy may be affected. Please pour the cat litter and clear out the
collection bucket before starting the machine, otherwise the machine can not
initialize the data; When adding cat litter, it should be lower than the
marked MAX line to avoid affecting the normal operation of the machine. This
product is suitable for most granular or small strip-shaped cat litter. It is
recommen-ded to buy brand cat litter. There are magnets installed in the front
end of this product. If patients with cardiac pace-makers or related want to
use this product, you need to consult the doctor; When the sterilization
function of ultraviolet lamp (UV) is working, do not look close; Product
should be stored or used to prevent infants, children and mental disorders to
touch.
HOW TO CONNECT TO THE APP
Step 1: Download & Registration
Scan the QR Code to download Tesla Smart APP. Or Search Tesla Smart in Apple
store or Google Play to install the APP•Open the Tesla Smart App, tap Register
to get an account with your phone number or E-mail. Sign in the App.
Add Device
Open your „ Tesla Sart“ APP, tap „+“ on the top right of the APP• Select
Device Type, tap „ confirm indicator rapidly blink“. It will fetch the
password of the Wi-Fi network your mobile phone is connected to.Tap „Confirm“
to connect to the device, when it appears „ successfully add 1device“, then
the connection is com-pleted and your devices is listed in your APP list.
FUNCTIONS AND FEATURES OF PRODUCT
When te cat enters the clean compartment, it will stop automatically. After the cat leaves the cleaning compartment, it will clean up automatically. Display the current weighing data. When there is no collection bucket, it will remind and stop; It is safer to stop when the cleaning chamber has a certain torque. Lower operating noise; Intelligent overweight protection; UV lamp sterilization; The collection bucket can be pushed and pulled on both sides, and the product can be placed against the wall; Voice broadcast.
PACKING LIST
- host
- UV lamp sterilization accessories
- Power adapter
- Appropriative garbage bag (gift)
- Instruction
- Warranty card (attached the instruction)
- Certificat of qualification (attached the instruction)
Please check the appearance of the carton or other packaging when unpacking and check all accessories. If damaged or missing, please contact the distributor or manufacturer immediately
MAIN TECHNICAL INDEX
- Product name: Tesla Smart Cat Toilet
- Version: TCL-PC-C101
- Power adapter: input AC100-240V/O,4A output DC12V/1A
- Rated power: 6W (without UV lamp sterilization power) UV lamp sterilization power: W5W
- Standby power: 0,5W
- Weighing range : 0,5 – 20kg (MAX)
- Weighing precision: ±0,01kg (static)
- Cat litter load: 3L
- Collecting bucket capacity : 3L
- Running noise: <55dB (A weighting)
- UV lamp working time: 15 minutes
- Classification of electrical appliance: II Type equipment
- Product size: lenght 655mm-width 642mm- height 605mm
- Net weight : 8±0,3kg
- Normal working environment: environment temperature 5-4 (FC, Relative humidity «93%, No condensation Storage and transportation environment: environment temperature – 20-60°C, Relative humidity «93%, no condensation
INSTRUCTION PRODUCT SKETCH
Preparation before starting up
Before connecting to the power adapter, prepare the following (otherwise the
machine‘s weight sensor cannot initialize the data):
- First load the cat litter to the silica gel cat litter pan (such as the maximal sand adding scale in the product sketch);
- Take out the garbage bag and put it back to the position.
Turn on
Connect the packaged power adapter to the machine (INDC12V at the bottom of
the back of the machine), the machine will automatically enter the standby
state.
Key operation:
When the machine is rotating, press the key lightly and the machine stops
working. Tap again to resume rotation.
Working state:
When the green indicator light is flashing, it indicates that the clean
capsule is about to rotate. The green light will go on when the cleaning
chamber rotates.
Weight display:
When ca tis using, it shows the weight of the cat.
No bucket remind:
After the collection bucket is taken out, it will be displayed and broadcast
by voice. The machine will stop working.
CLEANING AND MAINTENANCE
Clean the shell:
When the shell and other surfaces of the machine need to be cleaned, pull out
the power adapter and wipe with a clean, soft, slightly damp cloth soaked in
detergent to prevent liquid from seeping into the machine.
Note: There is circuit board inside the product. Do not allow liquid to
seep in. Clean the cleaning chamber and collecting bucket In order to keep the
environment and the machine clean, the cleaning chamber and the collection
bucket should be cleaned regularly. The cleaning chamber and the collection
bucket are detachable structure, which can be washed separately after
disassembly (the fastening screw in the cleaning chamber is made of stainless
steel), but they must be dried before being put back into use.
Disassembly steps:
- Unplug the power adapter;
- Take out the upper shell (refer to the product sketch) ;
- Remove the fixed hoop (refer to the product sketch) ;
- Take out the cleaning chamber
COMMON FAULTS THE CLEANING CHAMBER
- Make sure whether the layout is balanced or stable, on hard floor or wood floor;
- whether the cat litter mat is in contact with the machine; Rearrange the machine.
not work
- sensor initialization may be wrong;
- fault
Restart the machine;
If it still can not run normally, please consult customer service.
UV lamp does not work
- Replug the DC plug and readjust the position of sterilization accessory;
- Fault
I fit is still unable to work normally, please consult customer service.
If it still can not operate normally after the above mothod, please stop using the product and call the customer service hotline for consultation in time.
OTHER MATTERS
The illustrations in this manual are all schematics. If they are inconsistent
with the real object, please refer to the real object. Our company reserves
the right to change the technology and appearance of this product. We are
sorry for any change without FURTHER notice.
INFORMATION ABOUT DISPOSAL AND RECYCLING
This product is marked with the symbol for separate collection. The product
must be disposed of in accordance with the regulations for disposal of
electrical and electronic equipment (Directive 2012/19/EU on waste electrical
and electronic equipment). Disposal together with regular municipal waste is
prohibited. Dispose of all electrical and electronic products in accordance
with all local and European regulations at the designated collection points
which hold the appropriate authorisation and certification in line with the
local and legislative regulations. Correct disposal and recycling help to
minimise impacts on the environment and human health. Further information
regarding disposal can be obtained from the vendor, authorised service centre
or local authorities.
EU DECLARATION OF CONFORMITY
Hereby, Witty Trade s.r.o. declares that the radio equipment type TSL-PC-C101
is in compliance with EU directives. The full text of the EU declaration of
conformity is available at the following internet address:
teslasmart.com/declaration
- Connectivity: Wi-Fi 2,4 GHz IEEE 802.11b/g/n
- Frequency band: 2.400 – 2.4835 GHz
- Max. radio-frequency power (EIRP) : < 20 dBm
Manufacturer
Tesla Global Limited
Gee Chang Industrial Building,
121 Des Voeux Road Central
852 00 Hong Kong
www.teslasmart.com