ANOLiS E-BOX Remote Basic Installation Guide
- June 12, 2024
- ANOLiS
Table of Contents
INSTALLATION INSTRUCTIONS
E-BOX™ REMOTE BASIC
Fixture must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
STEP 1 REMOVE THE COVER
Unscrew four screws on top of the cover and remove the cover.
STEP 2 MOUNTING OF E-BOX
Drill four holes to the surface according to mounting holes spacing.
Fasten E-box to the surface holes via mounting holes on E-box and four
suitable fasteners.
STEP 3 CONNECTION
Strip these lengths for cable connections.
Connection – colour coding
Wiring connection
For Data and Power – EU color code shown
Note: In case that DMX output of DMX controller does not contain 120 Ohm,
the 120 Ohm resistor has to be connected between D+ and D-.
STEP 4 CABLE GLAND INSTALLATION
Use wrench size 24 for cable gland M20x1.5
Use wrench size 16 for cable gland M12x1.5
Install Cable glands individually!
Apply Loctite 5331 thread sealant on the plastic holder and Loctite 577 thread
locking compound on the gland body in the indicated locations prior to
assembly.
Failure to properly install cable glands will result in failure of the water
tight seal!
STEP 5 COVER THE E-BOX
Slide the cover back on top of E-box and fasten it with four original screws.
Before applying torque, make sure the thread is clean and functional.
ROBE lighting s. r. o.
Palackeho 416
757 01 Valasske Mezirici
Czech Republic
Tel.: +420 571 751 500
E-mail: info@anolis.eu
www.anolis.eu
www.anolislighting.com