Laserliner MultiMeter XP Professional Multimeter with Low Z Low Impedance Mode Instructions
- June 12, 2024
- Laserliner
Table of Contents
MultiMeter XP Professional multimeter with Low Z low impedance mode
MultiMeter XP Professional Multimeter with Low Z Low Impedance Mode
This professional multimeter allows fast and accurate measurement of voltage,
current, resistance, capacitance, frequency, duty factor and contact
temperature. Integrity and polarity can be determined using the diode test
function. The automatic continuity tester notifies the user via an acoustic
signal. The Digital Connection interface allows measured values to be
transferred to a smartphone for easy documentation.
The tool has an ergonomic, robust casing and an integrated torch for
illuminating the test area.
- Precise and quick measurement of voltage, current, resistance, capacitance, frequency and duty factor
- Integrity and polarity can be determined using the easy diode test function
- Automatic continuity tester with acoustic signal
- Simple transfer of measured data through Digital Connection interface to mobile phone
- Automatic range changeover and manual range preselection
- Practical, short-term storage of the last measured value by means of data hold function
MultiMeter XP | ORDER NO. 083.037A | EAN-CODE 4021563699407 | PU 1 |
---|
TECHNICAL SPECIFICATIONS
MEASURED VARIABLE| Direct current / alternating current
Direct voltage / alternating voltage
Resistance
Capacitance
Frequency
Temperature
---|---
FEATURES| automatic measuring range
Comparison measurement
MAX
MIN
AVG
HOLD automatic switch-off
Maximum voltage value function (peak)
AC VOLTAGE| Range / Resolution / Accuracy:
6.000V / 1 mV / ± (1.0% + 5)
60.00V / 10 mV / ± (1.0% + 5)
600.0V / 0.1V / ± (1.0% + 5)
1000V / 1V / ± (1.2% + 5)
Bandwidth: 50 … 1000 Hz
DC VOLTAGE| Range / Resolution / Accuracy:
600.0 mV / 0.1 mV / ± (0.5% + 8)
6.000V / 1 mV / ± (0.5% + 8)
60.00V / 10 mV / ± (0.8% + 5)
600.0V / 0.1V / ± (0.8% + 5)
1000V / 1V / ± (1.0% + 3)
DIMENSIONS (W X H X D)| 75 mm x 170 mm x 48 mm
| * ± accuracy = [(% of measured value (rdg)) + (number of least significant
digits (digit))]
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>