Laserliner MultiMeter XP Professional Multimeter with Low Z Low Impedance Mode Instructions

June 12, 2024
Laserliner

MultiMeter XPLaserliner MultiMeter XP Professional Multimeter with Low
Z Low Impedance Mode Professional multimeter with Low Z low impedance mode

MultiMeter XP Professional Multimeter with Low Z Low Impedance Mode

This professional multimeter allows fast and accurate measurement of voltage, current, resistance, capacitance, frequency, duty factor and contact temperature. Integrity and polarity can be determined using the diode test function. The automatic continuity tester notifies the user via an acoustic signal. The Digital Connection interface allows measured values to be transferred to a smartphone for easy documentation.
The tool has an ergonomic, robust casing and an integrated torch for illuminating the test area.

  • Precise and quick measurement of voltage, current, resistance, capacitance, frequency and duty factor
  • Integrity and polarity can be determined using the easy diode test function
  • Automatic continuity tester with acoustic signal
  • Simple transfer of measured data through Digital Connection interface to mobile phone
  • Automatic range changeover and manual range preselection
  • Practical, short-term storage of the last measured value by means of data hold function

Laserliner MultiMeter XP Professional Multimeter with Low Z Low Impedance
Mode - FigLaserliner MultiMeter XP Professional Multimeter with Low Z Low
Impedance Mode - Fig 1

MultiMeter XP ORDER NO. 083.037A EAN-CODE 4021563699407 PU  1

TECHNICAL SPECIFICATIONS

MEASURED VARIABLE| Direct current / alternating current
Direct voltage / alternating voltage
Resistance
Capacitance
Frequency
Temperature
---|---
FEATURES| automatic measuring range
Comparison measurement
MAX
MIN
AVG
HOLD automatic switch-off
Maximum voltage value function (peak)
AC VOLTAGE| Range / Resolution / Accuracy:
6.000V / 1 mV / ± (1.0% + 5)
60.00V / 10 mV / ± (1.0% + 5)
600.0V / 0.1V / ± (1.0% + 5)
1000V / 1V / ± (1.2% + 5)
Bandwidth: 50 … 1000 Hz
DC VOLTAGE| Range / Resolution / Accuracy
:
600.0 mV / 0.1 mV / ± (0.5% + 8)
6.000V / 1 mV / ± (0.5% + 8)
60.00V / 10 mV / ± (0.8% + 5)
600.0V / 0.1V / ± (0.8% + 5)
1000V / 1V / ± (1.0% + 3)
DIMENSIONS (W X H X D)| 75 mm x 170 mm x 48 mm
| * ± accuracy = [(% of measured value (rdg)) + (number of least significant digits (digit))]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals