MEAN WELL FDHC-100 AC-DC LED driver Constant Power Mode Instruction Manual
- June 4, 2024
- MEAN WELL
Table of Contents
FDHC – 100 series
100W Constant Power Mode LED Driver
Instruction Manual
Features
- Constant Power mode output
- Metal housing design
- Built-in Input OVP (Over Voltage Protection)
- Built-in active PFC function, PF>0.9, THD<10%
- Full Power at 70-100% max. current
- No load power consumption <0.6W
- IP67 rating for indoor or outdoor installations
- Output current adjustable via potentiometer
- 3 years warranty
Applications
- LED flood lighting
- LED decorative lighting
- LED architectural lighting
- LED street lighting
Description
FDHC-100 series is a 100W AC/DC LED power supply featuring the constant power output mode, FDHC-100 operates from 180 295VAC, and output current can be adjusted between 490mA to 1050mA & 1300mA 3000mA. Thanks to the high efficiency of up to 90%, with the fanless design, the entire series is able to operate for -30°C – +90°C case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. FDHC-100 is equipped with an output current adjustable function so as to provide optimal design flexibility for the LED lighting system.
Model Encoding
SPECIFICATION
MODEL | FDHC-100L | FDHC-100H |
---|
OUTPUT
| OUTPUT CURRENT REGION| 490~ 1050mA(700mA default)| 1300~
3000mA(1850mA default)
CONSTANT POWER Note.2| 100W
CONSTANT CURRENT REGION Note.2| 96 ~ 142V| 30 ~ 54V
FULL POWER CURRENT RANGE| 700~ 1050mA| 1850~ 3000mA
OPEN CIRCUIT VOLTAGE (max.)| 154V max.| 59V max.
CURRENT TOLERANCE| ±5.0%
SET UP TIME Note.3| 1000ms/230VAC
INPUT
| VOLTAGE RANGE Note.5| 180 ~ 295VAC
(Please refer to the “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.9(@load≧70%/230VAC; @load≧75%/277VAC)
(Please refer to the “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 10%(@full load/220VAC 50Hz)
(Please refer to the “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.)| 90%
AC CURRENT (Typ.)| 0.7A / 230VAC 0.5A/277VAC
INRUSH CURRENT (Typ.)| COLD START 50A(twidth=270μs measured at 50%
Speak)/230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 9 units (circuit breaker of
type B) / 16 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
NO LOAD POWER CONSUMPTION| <0.6W
PROTECTION
| SHORT CIRCUIT| Hiccup mode recovers automatically after the fault
condition is removed
OVER TEMPERATURE| Shut down output voltage, recovers automatically after
fault condition is removed
INPUT OVP
| 305 ~ 315VAC (Shut down output voltage when the input voltage exceeds
protection voltage)
295 ~ 305VAC (Auto recovery)
can survive input voltage stress of 440V for 48 hours
ENVIRONMENT
| WORKING TEMP.| Tcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1 cycle, the period for 72min. each
along X, Y, and Z axes
SAFETY & **EMC**
| SAFETY STANDARDS| EN61347-1,EN61347-2-13 independent,
EN62384,IS15885(part 2/ sec.13),IP67 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to EN55015, EN61000-3-2 Class C (load≧70%) ;
EN61000-3-3
EMC IMMUNITY| Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light
industry level(surge immunity: Line-Earth:6KV,Line-Line:3KV)
OTHERS
| MTBF| 1225.4K hrs min. Telcordia SR-332 (Bellcore) 430.9Khrs min. MIL-
HDBK-217F (25℃)
DIMENSION| 1805333mm (LWH)
PACKING| 0.625Kg;24pcs /16Kg / 0.8CUFT
NOTE|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated
current, and 25℃ of ambient temperature.
2. Please refer to ” OUTPUT CURRENT SETTlNG “.
3. Length of set up time is measured at first cold start. Turning ON/OFF the
power supply may lead to an increase in the setup time.
4. The driver is considered a component that will be operated in combination
with the final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC
Directive on the complete installation again.
5. Please refer to the warranty statement on MEAN WELL’s website at
http://www.meanwell.com
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of
5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
7. For any application note and lP waterproof function installation caution,
please refer to our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
※ Product Liability Disclaimer: For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
BLOCK DIAGRAM
OUTPUT CURRENT SETTING
※ -I V Operating Area
Output rated current level can be adjusted through a built-in potentiometer
|
---|---
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
※ case at 80℃
EFFICIENCY vs LOAD
FDHC-100 series possess superior working efficiency that up to 90% can be
reached in field applications.
Tcase at 80℃
AC input voltage drop vs. output current characteristics
AC input voltage drop | 10% | 8% | 5% | 3% |
---|---|---|---|---|
Io drop | <13% | <11% | <6% | <3% |
NOTE: Output current will return to the rated value within 90ms
MECHANICAL SPECIFICATION
CASE NO.: 261A Unit: mm
◎ Note: Please connect the case to FG for the complete EMC deliverance.
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html
User’s Manualhttp://www.meanwell.com.cn/Upload/PDF/LED_EN.pdf
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>