MAGMATIC MAGMA FOG 1500 IP Water Based Fog Machine User Manual
- June 12, 2024
- MAGMATIC
Table of Contents
- MAGMA FOG 1500 IP Water Based Fog Machine
- GENERAL INFORMATION
- LIMITED WARRANTY (USA ONLY)
- IP65 RATED
- SAFETY GUIDELINES
- SAFETY GUIDELINES
- OVERVIEW
- INSTALLATION
- TORQUE SETTINGS
- TORQUE SCREW LOCATIONS & SPECS
- SET UP
- CONTROL PANEL
- SYSTEM MENU
- MESSAGE ICONS
- DMX CHANNEL FUNCTIONS & VALUES
- DIMENSIONAL DRAWINGS
- TROUBLE SHOOTING
- CLEANING & MAINTENANCE
- SPECIFICATIONS
- Documents / Resources
MAGMA FOG 1500 IP User Manual
MAGMA FOG 1500 IP Water Based Fog Machine
©2023 MAGMATIC EFFECTS all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without
notice. MAGMATIC EFFECTS logo and identifying product names and numbers
herein are trademarks of MAGMATIC EFFECTS. Copyright protection claimed
includes all forms and matters of copyrightable materials and information now
allowed by statutory or judicial law or hereinafter granted. Product names
used in this document may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged. All non-MAGMATIC brands and
product names are trademarks or registered trademarks of their respective
companies.
MAGMATIC EFFECTS and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
MAGMATIC EFFECTS | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com |
sales@magmaticeffects.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax |
www.elationlighting.eu |
info@elationlighting.eu
Elation Professional Mexico | AC Santa Ana 30 | Parque Industrial Lerma,
Lerma, Mexico 52000 +52 728-282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of
this document may be available online.
Please check www.elationlighting.com for the
latest revision/update of this manual before beginning installation and/or
programming.
Date| Document
Version| Software
Version| M D X Channel Mode| Notes
---|---|---|---|---
7/11/22| 1.0| 1.0| 1/2/4| Initial Version
4/10/23| 1.| N/C| No Change| Updated Safety Guidelines, Installation,
Dimensional Drawings
5/17/23| 1.| N/C| No Change| Updated Specifications, Dimensional Drawings
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and
thoroughly before attempting to operate this device. These instructions
contain important safety and use information.
This product is intended to be used by professionally trained personnel only
and is not suitable for private use.
Every device has been thoroughly tested and has been shipped in perfect
operating condition.
Carefully check the shipping carton for damage that may have occurred during
shipping. If the carton is damaged, carefully inspect the device for damage,
and be sure all accessories necessary to install and operate the device have
arrived intact. In the event that damage has been found or parts are missing,
please contact our customer support team for further instructions. Please do
not return this device to your dealer without first contacting customer
support. Please do not discard the shipping carton in the trash. Please
recycle whenever possible.
BOX CONTENTS
Power Cable (x1)
CUSTOMER SUPPORT
Contact MAGMATIC customer service for any product related service and support
needs.
Also visit forums.elationlighting.com with questions, comments, or
suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
sales@magmaticeffects.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 63 | Fax: +31 45 546 85 96 |
support@elationlighting.eu
REPLACEMENT PARTS: Please visit
parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
NEVER POINT OR AIM A FOG MACHINE TOWARDS PEOPLE OR THEIR CLOTHING. THIS UNIT
EMITS HOT VAPOR AND SHOULD BE USED WITH THE SAME CARE THAT YOU WOULD OBSERVE
WHEN USING AN ELECTRIC KETTLE OR IRON.
LIMITED WARRANTY (USA ONLY)
A. Magmatic Effects hereby warrants, to the original purchaser, Magmatic
products to be free of manufacturing defects in material and workmanship for a
period of two years (730 days) from the original date of purchase. This
warranty excludes discharge lamps and all product accessories. This warranty
shall be valid only if the product is purchased within the United States of
America, including possessions and territories. It is the owner’s
responsibility to establish the date and place of purchase by acceptable
evidence, at the time service is sought.
B. For warranty service, send the product only to the Magmatic Effects
factory. All shipping charges must be pre-paid. If the requested repairs or
service (including parts replacement) are within the terms of this warranty,
Magmatic Effects will pay return shipping charges only to a designated point
within the United States. If any product is sent, it must be shipped in its
original package and packaging material. No accessories should be shipped with
the product. If any accessories are shipped with the product, Magmatic
Effects shall have no liability what so ever for loss and/or or damage to any
such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are
altered or removed; if the product is modified in any manner which Magmatic
Effects concludes, after inspection, affects the reliability of the product;
if the product has been repaired or serviced by anyone other than the
Magmatic Effects factory unless prior written authorization was issued to
purchaser by Magmatic Effects; if the product is damaged because not properly
maintained as set forth in the product instructions, guidelines and/or user
manual.
D. This is not a service contract, and this warranty does not include any
maintenance, cleaning or periodic check-up. During the periods as specified
above, Magmatic Effects will replace defective parts at its expense, and will
absorb all expenses for warranty service and repair labor by reason of
defects in material or workmanship. The sole responsibility of Magmatic
Effects under this warranty shall be limited to the repair of the product, or
replacement thereof, including parts, at the sole discretion of Magmatic
Effects. All products covered by this warranty were manufactured after January
1, 1990, and bear identifying marks to that effect.
E. Magmatic Effects reserves the right to make changes in design and/or
performance improvements upon its products without any obligation to include
these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to
any accessory supplied with the products described above. Except to the extent
prohibited by applicable law, all implied warranties made by Magmatic Effects
in connection with this product, including warranties of merchantability or
fitness, are limited in duration to the warranty periods set forth above. And
no warranties, whether expressed or implied, including warranties of
merchantability or fitness, shall apply to this product after said periods
have expired. The consumer’s and/or dealer’s sole remedy shall be such repair
or replacement as is expressly provided above; and under no circumstances
shall Magmatic Effects be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this
product.
G. This warranty is the only written warranty applicable to Magmatic Effects
products and supersedes all prior warranties and written descriptions of
warranty terms and conditions heretofore published.
To obtain warranty service, a Return Material Authorization (RMA) number must
first be obtained from MAGMATIC. It is the Customer’s responsibility to
provide product proof of purchase and serial number by acceptable evidence
such as an invoice copy or an approved MAGMATIC Extended Warranty Certificate
(“EWC”) and any relevant maintenance records at the time warranty service is
sought.
Failure to provide acceptable evidence of product proof of purchase or EWC and
any relevant maintenance records may be cause for denial of warranty service.
Products returned for warranty service must be sent without any accessories
(i.e., power, data, and safety cables, brackets, clamps, rigging hardware,
frost filters, gel frames, barn doors, lenses, hoses, nozzles, rack mounting
hardware, etc.), must be boxed using the original and/or suitable packaging
materials (double-box and foam) that provides ample product protection for
ground and/or air freight transit, and must be shipped freight pre-paid and
insured to MAGMATIC in Los Angeles, CA or a MAGMATIC Authorized Service
Center. The RMA number must be clearly written on the outside of the return
box, and a brief description of the problem and the RMA number must be
documented and included in the box.
Products returned for warranty service without an RMA number clearly marked on
the outside of the package will be refused and returned to the shipper at the
Customer’s expense. Products returned for warranty service, which are received
damaged due to inadequate and/or improper packaging and/ or due to damage
caused by the shipping carrier, may incur additional repair charges before
warranty service begins and/or may void this warranty. If any product
accessories (included and/or optional) are shipped with the product, MAGMATIC
and/or the MAGMATIC Authorized Service Center shall have no liability what so
ever for the loss and/or damage to any such accessories, nor the safe return
thereof. If the requested warranty repairs or service (including parts
replacement) are within the
IP65 RATED
The International Protection (IP) rating system is commonly expressed as “IP”
(Ingress Protection) followed by two numbers (i.e. IP65), where the numbers
define the degree of protection. The first digit (Foreign Bodies Protection)
indicates the extent of protection against particles entering the fixture, and
the second digit (Water Protection) indicates the extent of protection against
water entering the fixture. An IP65 rated lighting fixture is designed and
tested to protect against the ingress of dust (6), and low-pressure water
jets from any direction (5).
NOTE: THIS FIXTURE IS INTENDED FOR TEMPORARY OUTDOOR USE ONLY!
Maritime/Coastal Environment Installations: A coastal environment is seaside
adjacent, and caustic to electronics through exposure to atomized salt-water
and humidity, whereas maritime is anywhere within 5-miles of a coastal
environment.
NOT suitable for maritime/coastal environment installations. Installing this
fixture in a maritime/coastal environment may cause corrosion and/or excessive
wear to the interior and/or exterior components of the fixture. Damages
and/or performance issues resulting from installation in a maritime/coastal
environment will void the manufacturer’s warranty, and will NOT be subject to
any warranty claims and/or repairs.
Maritime installations require additional preparation, and additional service
intervals may be needed given the maritime use. In general, IP ratings
presuppose freshwater conditions VS maritime conditions, which are typically
more “caustic” to IP fixtures (both internally and externally). A duty-cycle
may also be needed when units are not in use. During times of high humidity
and colder temperatures, condensation may occur internally so the fixture may
require a duty-cycle to bring it up to running temperature, allowing any
accumulation of moisture to be expelled via the vent valve. Recommendations
can change based on installation environmental circumstances. A waterproof
dome or similar device is recommended for use in permanent outdoor
installations. When using a dome, refer to manufacturer recommendations for
duty-cycle.
NOTE: NOT ALL FEATURES LISTED ARE AVAILABLE ON ALL FIXTURES; THE FOLLOWING
INSTRUCTIONS MAY NOT APPLY. CONTACT SUPPORT FOR ADDITIONAL DETAILS.
Exterior Maintenance: Inspect the exterior every 30-days. The unit must be
powered off/disconnected.
The chassis should be inspected for any signs of contaminants. Inspect optics
to determine if the lens is obstructed, then clean optics and chassis
accordingly. Based on initial finding, schedule maintenance accordingly,
keeping in mind that exterior maintenance will be required. Even if the
luminaires are NOT in use, maintenance will still be needed given its location
(exterior use). The use of a durable type of wax on the chassis is recommended
since it will help prevent contaminant build up. Inspect both power and data
lines for any signs of contaminants or corrosion. Periodically reapplying di-
electric grease, especially in coastal environments. If any signs of
corrosion/contaminants are present, clean thoroughly, and/or replace
connectors, then reapply di-electric grease. Typically, this should be done
annually, or any time an opportunity presents itself. As a preventive measure,
annual replacement of both vent valves is recommended. The vent valve
membrane can become contaminated and/or clogged causing improper venting of
humidity within the luminaire. Inspect all mounting hardware as a precaution.
Interior Maintenance: Inspect the interior every 30-days. The unit must be
powered off/disconnected.
- Inspect zoom/focus mechanism, clean optics, lubricate linear bearings (Krytox oil) as needed, inspect belts for wear
- Inspect all rotating effect wheels, manually rotate them, note any resistance
- Inspect all remaining rotating belts for any wear
- Inspect all fans, clean as needed, check rotation, check connections
- Inspect CMY module, manually move flags and check for signs of resistance, and if needed, clean guide rods first, then reapply a thin layer of grease (moly lube)
- Clean interior with low-volume compressed air, then clean optics prior to reassembly of head covers
Although the base has limited moving parts, the pan belt should also be
inspected for wear. Remember to always perform an IP test anytime a cover is
removed.
There is no specific time frame regarding the routine replacement of parts
such as belts/stepper motors, PCBs, or LEDs. These items should only be
replaced on an as needed bases, except for cooling fans, which should be
replaced once the luminaries reach 10,000-hours. This is a prophylactic
measure intended to keep the unit running as cool as possible, insuring proper
function of all internal components. A complete service breakdown is
available, please contact
service@elationlighting.com for any
needed parts or manuals.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Magmatic Effects is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.
| PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED.
---|---
| THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS DEVICE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
| DO NOT PLUG THIS UNIT INTO A DIMMER PACK
DO NOT REMOVE THE COVER UNDER ANY CONDITIONS KEEP UNIT IN AN UPRIGHT POSITION
NEVER OPERATE THIS UNIT WITH THE COVER REMOVED UNPLUG FROM POWER DURING LONG
PERIODS OF NON-USE
ENSURE TANK IS EMPTY BEFORE STORAGE OR TRANSPORT DO NOT MOVE WHEN FILLED WITH
FLUID
DISCONNECT POWER BEFORE ADDING FLUID OR PERFORMING MAINTENANCE
DO NOT TILT THE MACHINE MORE THAN 30 DEGREES WHILE IN USE
IP65| FIXTURE IS COMPLETELY DUST TIGHT AND PROTECTED AGAINST LOW
PRESSURE WATER JETS FROM ANY DIRECTION
PORTS MUST BE SEALED WHEN NOT IN USE TO MAINTAIN IP RATING!
SAFETY GUIDELINES
- CAUTION: Fog machines may set off smoke alarms!
- Do not attempt installation and/or operation of this device without proper knowledge of how to do so.
- Do not point or direct fog output in an unsafe direction.
- Do not touch the front nozzle while the machine is in operation, or immediately after the device has been shut down, as the nozzle will be hot during operation.
- Do not shake device, and avoid brute force when installing and/or operating.
- Be sure to save the packing carton in the unlikely event the device may have to be returned for service.
- Be sure that the local power outlet matches the required voltage for the device.
- Do not remove components or disassemble the device. There are no user-serviceable parts inside.
- Never connect this device to a dimmer pack.
- Do not attempt to operate this device if it has been damaged in any way.
- Never use this device with the cover removed.
- Do not attempt to operate this device if the power cord has been frayed, crimped, and/or damaged. Replace any damaged power cords with new cords of the same power rating.
- Do not remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
- Always disconnect from main power before making any connection, performing cleaning or maintenance, or adding or draining fluid.
- Always drain fluid before moving the device.
- Always be sure to mount this device in an area that will allow proper ventilation.
- Always disconnect power cords during long periods of non-use.
- Always mount this unit in a safe and stable matter.
- Please route your power cord out of the way of foot traffic. Power cords should be routed so they are not likely to be walked on, or pinched by items placed upon or against them.
- The device should be serviced by qualified service personnel when:
• The power cords or plugs have become damaged.
• Objects have fallen on the unit causing damage to the outer casing.
• The device does not operate normally or exhibits a marked change in performance.
OVERVIEW
INSTALLATION
CLAMP INSTALLATION
This unit features a mounting yoke with integrated clamp attachment points, as
well as a safety cable loop located near the fluid tank (see the illustration
below). When mounting this fixture to truss, be sure to secure appropriately
rated clamps (not included) to the mounting yoke, and attach a separate
SAFETY CABLE of the appropriate rating to the safety cable loop. Please note
that at least two mounting clamps are required to securely install this device
in a suspended environment.
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE WHEN INSTALLING THIS UNIT IN A SUSPENDED
ENVIRONMENT TO ENSURE THAT THE UNIT WILL NOT FALL IN THE EVENT THAT THE CLAMP
FAILS.
RIGGING
Overhead rigging requires extensive experience, including but not limited to:
calculating working load limits, understanding the installation material being
used, and periodic safety inspection of all installation material and the
device. If you lack these qualifications, do not attempt the installation
yourself. Improper installation can result in bodily injury.
OPTIONAL MAGFLY WIRELESS CARD
The Magma Fog 1500 IP features 2 card slots for optional MagFly wireless
receiving cards. These card slots are located behind the the MagFly input
cover. For ordering information, see ACCESSORIES section on page 23.
TORQUE SETTINGS
TORQUE DRIVERS (Recommended): UTICA TS-30 (Shown)
TORQUE DRIVER (Alternate):
- Proto J6107A
- Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES! TO
CONFIRM THE IP65 INTEGRITY AFTER DISASSEMBLY, TEST THE FIXTURE USING THE IP
TESTER. CONTACT SERVICE SERVICE FOR MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY
RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING YOUR FACE,
EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE FIXTURE WHILE PERFORMING THIS
TEST!
IP PRESSURE TESTING PARAMETERS
Low Pressure Limit| High Pressure Limit| Steady/Hold Time
3.04PSI
21kPa| 4.49PSI
31kPa| 30 seconds
TORQUE SCREW LOCATIONS & SPECS
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. Please refer to the drawing below for screw locations, quantity, and torque settings.
SET UP
- Open the shipping carton and carefully remove the unit.
- Be sure to remove ALL the packing material, paying particular attention to the area around the fog outlet vent.
- Set the unit on a flat dry surface.
- Unscrew the tank cap and fill the reservoir with Atmosity Extreme Filtered Fog Fluid (AEF-2L, AEF-4L, AEF-20L). Never run the unit on anything other than approved, MAGMATIC branded fluid, as doing so can result in severe damage to your device.
- Screw the tank cap back onto the fluid tank. Be careful not to pinch, twist, or tangle the feed tube connected to the tank cap.
- Connect the included power cable to the back of the unit (located underneath the touch-screen display) and connect the the unit to a properly rated power source. Allow the unit to warm up for at least fourteen (14) minutes before beginning fog emission.
CONTROL PANEL
This fixture includes a system menu with an easy to navigate touch screen
control panel where all necessary settings and adjustments are made. When
first powering on the fixture, the fixture’s main menu will be displayed (see
Main Menu Screen below).
Press the main menu icon you would like to access. Use the ENTER button to
access sub menus and use the UP and DOWN buttons to make adjustments. Press
the ENTER button to confirm your adjustments. You may exit the main menu at
any time without making any adjustments by pressing the BACK/EXIT button.
SYSTEM MENU
| DMX SET| DMX Addr| 1 – 512| DMX Addressing
---|---|---|---|---
DMX Mode| 1-ch| DMX Channel Mode Selection
2-c h
4-ch
| PERSONALITY| MagApp Set| MagApp Name| 0-XXXX| Displays MagApp
Name
MagApp Passcode| 00000000 –
00009999| MagApp Password
MagApp IP| 0-255.0| Display IP Address
MagApp Port| 0-65535| Network Port
MagApp Reset| Complete
reset| Network connection
Failed, try again|
MagApp -> DMX & Magfly| On/Off| Magfly Transmit On
LCD Set| Screen OFF:
Never/10s/40s/lm n/2min/5min/10m in/20min| Display Blackout Time
Magfly Set| Magfly Channel 0-14| Magfly Channel Setting
Magfly: On/Off| Magfly Activation
No Fluid| On/Off| Activate/Deactivate No Fluid Warning
MagRF Learn| Will notify whether MagRF connection is successful after 20s
Last State| Yes/No| Activate/Deactivate last state
Default| Press “ENTER”| Restore Factory
| MANUAL| Fog| 1%-100 (Output is continuous at 20% or lower)| Manual Control
| TIMER| Fog| 1%-100% (Output is continuous at 20% or lower)| Fog Output
Duration| 0-250s| Duration Setting
Interval| 0-2500s| Interval Setting
| PRESET| Preset I:10s Duration, Fog 100%, 4s Interval| Preset Setting 1
(not adjustable)
---|---|---|---
Preset 2:30s Duration, Fog 80%, lOs Interval| Preset Setting 2
(not adjustable)
Preset 3: 60s Duration, Fog 60%, 30s Interval| Preset Setting 3
(not adjustable)
Preset 4:150s Duration, Fog 40%,120s Interval| Preset Setting 4
(not adjustable)
Preset 5: 200s Duration, Fog 30%, 200s Interval| Preset Setting 4
(not adjustable)
| INFORMATION| State| Normal / Error| Machine Status
Slot 1| Null / MagFly / MagApp / MagRF| Slot 1 Status
Slot 2| Null / MagFly / MagApp / MagRF| Slot 2 Status
Last Control| LCDauto/LCD_manual/DMX/ MagApp/MagRF/MagRemote/Error| Current
Control Status
MagRemote State| YES/NO| Remote Control Status
MagApp Connect| Null/Phone/Route/No| Wifi Connection Status
MagApp IP| NO / 0-255,0–255,0–255,0–255| Current Wifi IP Status
MagFly CH.| 0-14| Current Magfly Channel Setting
DMX Addr.| 1-512| Current DMX Address
DMX Mode| 1 or 2 or 4| Current DMX Ch. Mode
Timer Output| 0% -100%| Current Timer Output
Timer Int.| 0-2500s| Current Timer Interval
Timer Dur.| 0-250s| Current Timer Duration
Heating| 0%-100%| Heater Progress
No Fluid| Normal / Empty| Current Fluid Status
Heater State| Normal / Error/No Heat| Current Heater Status
LCD Ver.| VX.X| Display Version
Sftwr Ver.| VX.X| Software Version
MESSAGE ICONS
Icon | Description |
---|---|
Icon appears when MagFly module is connected. 4-bar symbol on the right |
indicates signal strength, with 0 bars being weakest and 4 bars being
strongest.
| Icon appears when MagApp module is connected. 4-bar symbol on the right
indicates signal strength, with 0 bars being weakest and 4 bars being
strongest.
| Icon appears when Mag RF module is connected. Note that the icon will only
appear if an RF signal exists.
| Icon appears when MagRemote is connected.
| Icon indicates that the fluid tank is empty, and disappears when fluid is
added to the tank.
DMX CHANNEL FUNCTIONS & VALUES
MAGMATIC MAGMA FOG 1500 IP: DMX TRAITS
1-CH| 2-CH| 4-CH| VALUES| FUNCTION
| 1| 1| | FOG
000-005| OFF
006-255| ON
1| 2| 2| | VOLUME
0-255| 1%-100%
(Output is continuous
at 20% or lower)
| | 3| | DURATION
000-005| Os
006-255| 1s-250s
| | 4| | INTERVAL
000-005| Os
006-255| 10S-2500s
RDM PARAMETERS
NOTE: In order for RDM to work properly, RDM enabled equipment must be
used throughout the entire system, including DMX data splitters and wireless
systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512
data standard for lighting, and allows the DMX systems of the fixtures to be
modified and monitored remotely. This protocol is ideal for instances in which
a unit is installed in a location that is not easily accessible.
With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM
enabled controller to send out a signal to devices on the wire, as well as
allowing the fixture to respond (known as a GET command). The controller can
then use its SET command to modify settings that would typically have to be
changed or viewed directly via the unit’s display screen, including the DMX
Address, DMX Channel Mode, and Temperature Sensors.
FIXTURE RDM INFORMATION:
Device Model ID | RDM Code | Personality ID |
---|---|---|
1110 | 22A6H | 1 (1) |
2 (2)
4 (3)
Please be aware that not all RDM devices support all RDM features, and
therefore it is important to check beforehand to ensure that the equipment
that you are considering includes all of the features that you require.
The following parameters are accessible in RDM on this device:
[0x1000] IDENTIFY_DEVICE
[0x00F0] DMX_START_ADDRESS
[0x00C0] SOFTWARE_VERSION_LABEL
[0x0060] DEVICE_INFO
[0x0080] DEVICE_MODEL_DESCRIPTION
[0x0081] MANUFACTURER_LABEL
[0x0082] DEVICE_LABEL
[0x0050] SUPPORTED_PARAMETERS
[0x00E1] DMX_PERSONALITY_DESCRIPTION
[0x00E0] DMX_PERSONALITY
[0x0200] SENSOR_DEFINITION
[0x0201] SENSOR_VALUE
DIMENSIONAL DRAWINGS
TROUBLE SHOOTING
If you experience low output, pump noise, or no output at all, disconnect the device and discontinue use immediately. Do not attempt to continue operation as this may damage the machine. Check the fluid level, the breaker, and the wall outlet to make sure that it is sending power. If all the above factors do not appear to be causing the issue, and the unit still fails to operate correctly, the unit will require service. Please contact Magmatic Effects for assistance (contact information on page 4).
CLEANING & MAINTENANCE
When storing your device, be sure to store in a cool area. Cover the device so that dust does not build up on the device. When storing for long periods of time it is highly advisable to run the device at least once every 3-4 months. Long periods of inactivity can severely shorten the life of your device. Only run Magmatic’s Atmosity Extreme Filtered fog fluid through your machine. Never run plain water, vinegar, or any other liquid solution through your device, as doing so will severely damage your device.
SPECIFICATIONS
PERFORMANCE
Rated Power: 1500W
Max Output: 60,000 CFM (cu ft/min.)
Ready Time: Initial = 14 Minutes
Fluid Capacity: 1.32 gallons (5 liters)
Fluid Consumption: 6.76 oz/min (200 ml/min)
*approximate
COMPATIBLE FLUID
Atmosity Extreme Filtered Fog Fluid (AEF-2L, AEF-4L, AEF-20L)
CONSTRUCTION
Thermally Protected Heat Exchanger
Rugged Case Design
Convenient Carry Handles
CONTROL
3 DMX Channel Modes (1 / 2 / 4)
Onboard LCD Touch Control Panel
DMX-512 and RDM Protocol Support
Optional MAGFLY Wireless DMX Transceiver
Optional MAGRF Wireless and MAGREMOTE Wired Remotes
CONNECTIONS
Locking 5pin XLR Connector, DMX In/Out
IP65 Locking Power Connector In
With Wired Digital Communication Network
SIZE / WEIGHT
Length: 25.5 in. (648mm)
Width: 13.3 in. (337mm)
Height: 16.2 in. (411mm)
Weight: 61.3 lbs. (27.8kg)
ELECTRICAL
AC120V 60Hz (US Version)
AC230V 50Hz (EU Version)
20A @ 120VAC(NFB)
10A @ 230VAC – 240VAC
Max Power Consumption: 1600W
THERMAL
Maximum Ambient Temperature (Ta max) 104°F (40°C)
Exterior Surface Temperature, Steady State: 149°F (65°C)
ACCESSORIES
MagFLY (MSR934) Wireless DMX Transceiver Module
MagRF (MSR912) RF Module and Wireless Remote
APPROVALS / RATINGS
CE | IP65
Specifications are subject to change without notice.
Documents / Resources
|
MAGMATIC MAGMA FOG 1500 IP Water Based Fog
Machine
[pdf] User Manual
MAGMA FOG 1500 IP, MAGMA FOG 1500 IP Water Based Fog Machine, Water Based Fog
Machine, Based Fog Machine, Fog Machine, Machine
---|---
References
Read User Manual Online (PDF format)