Magmatic 1450W high velocity co2 simulator SIDE WINDER User Manual
- June 5, 2024
- MAGMATIC
Table of Contents
Magmatic 1450W high-velocity co2 simulator SIDEWINDER
©2021 MAGMATIC EFFECTS all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without
notice. MAGMATIC EFFECTS logo and identifying product names and numbers herein
are trademarks of MAGMATIC EFFECTS. Copyright protection claimed includes all
forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this
document may be trademarks or registered trademarks of their respective
companies and are hereby acknowledged. All non-MAGMATIC brands and product
names are trademarks or registered trademarks of their respec-tive companies.
MAGMATIC EFFECTS and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
MAGMATIC EFFECTS | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com |
sales@magmaticeffects.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax |
www.elationlighting.eu |
info@elationlighting.eu
Elation Professional Mexico | AC Santa Ana 30 | Parque Industrial Lerma,
Lerma, Mexico 52000 +52 728-282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of
this document may be available online.
Please check www.elationlighting.com for the
latest revision/update of this manual before beginning installation and/or
programming.
Date| Document Version| Software Version| DMX
Channel Mode| Notes
---|---|---|---|---
10/15/20| 1.0| 1.0| 1 / 4 / 7 Channels| Initial Release
12/11/20| 2.0| N/C| N/C| Updated Dimensional Drawings & Specifications
07/12/21| 3.0| N/C| N/C| Updated Operation & Specifications
12/13/21
| ****
4.0
| ****
N/C
| ****
N/C
| Updated Safety Guidelines, System Menu, & Specifications; added FCC Statement, MagFly, and MagRF sections.
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and
thoroughly before attempting to operate this device. These instructions
contain important safety and use information.
This product is intended to be used by professionally trained personnel only
and is not suitable for private use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect
operating condition. Care-fully check the shipping carton for damage that may
have occurred during shipping. If the carton is damaged, carefully inspect the
device for damage, and be sure all accessories necessary to install and
operate the device have arrived intact. In the event that damage has been
found or parts are missing, please contact our customer support team for
further instructions. Please do not return this device to your dealer without
first contacting customer support. Please do not discard the shipping carton
in the trash. Please recycle whenever possible.
BOX CONTENTS
Twist-locking power cable (x1)
CUSTOMER SUPPORT
Contact MAGMATIC customer service for any product related service and support
needs.
Also visit forums.elationlighting.com with questions, comments, or
suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
sales@magmaticeffects.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 63 | Fax: +31 45 546 85 96 |
support@elationlighting.eu
REPLACEMENT PARTS: Please visit
parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
NEVER POINT OR AIM A FOG MACHINE TOWARD PEOPLE OR THEIR CLOTHING. THIS UNIT
EMITS HOT VAPOR AND SHOULD BE USED WITH THE SAME CARE THAT YOU WOULD OBSERVE
WHEN USING AN ELECTRIC KETTLE OR IRON.
LIMITED WARRANTY (USA ONLY)
- Magmatic Effects hereby warrants, to the original purchaser, Magmatic products to be free of man-ufacturing defects in material and workmanship for a period of two years (730 days) from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including pos-sessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
- For warranty service, send the product only to the Magmatic Effects factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Magmatic Effects will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging mate-rial. No accessories should be shipped with the product. If any accessories are shipped with the prod-uct, Magmatic Effects shall have no liability what so ever for loss and/or or damage to any such acces-sories, nor for the safe return thereof.
- This warranty is void if the product serial number and/or labels are altered or removed; if the prod-uct is modified in any manner which Magmatic Effects concludes, after inspection, affects the reli-ability of the product; if the product has been repaired or serviced by anyone other than the Magmatic Effects factory unless prior written authorization was issued to purchaser by Magmatic Effects; if the product is damaged because not properly maintained as set forth in the product instructions, guide-lines and/or user manual.
- This is not a service contract, and this warranty does not include any maintenance, cleaning or peri-odic check-up. During the periods as specified above, Magmatic Effects will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Magmatic Effects under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Magmatic Effects. All products covered by this warranty were manufactured after January 1, 1990, and bear identifying marks to that effect.
- Magmatic Effects reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manu-factured.
- No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied war-ranties made by Magmatic Effects in connection with this product, including warranties of merchant-ability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Magmatic Effects be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
- This warranty is the only written warranty applicable to Magmatic Effects products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
WARRANTY RETURNS (USA ONLY)
To obtain warranty service, a Return Material Authorization (RMA) number must
first be obtained from MAGMATIC. It is the Customer’s responsibility to
provide product proof of purchase and serial num-ber by acceptable evidence
such as an invoice copy or an approved MAGMATIC Extended Warranty Certificate
(“EWC”) and any relevant maintenance records at the time warranty service is
sought. Failure to provide acceptable evidence of product proof of purchase or
EWC and any relevant mainte-nance records may be cause for denial of warranty
service.
Products returned for warranty service must be sent without any accessories
(i.e., power, data, and safety cables, brackets, clamps, rigging hardware,
frost filters, gel frames, barn doors, lenses, hoses, nozzles, rack mounting
hardware, etc.), must be boxed using the original and/or suitable packag-
ing materials (double-box and foam) that provides ample product protection for
ground and/or air freight transit, and must be shipped freight pre-paid and
insured to MAGMATIC in Los Angeles, CA or a MAGMATIC Authorized Service
Center. The RMA number must be clearly written on the outside of the return
box, and a brief description of the problem and the RMA number must be
documented and included in the box.
Products returned for warranty service without an RMA number clearly marked on
the outside of the package will be refused and returned to the shipper at the
Customer’s expense. Products returned for warranty service, which are received
damaged due to inadequate and/or improper packaging and/or due to damage
caused by the shipping carrier, may incur additional repair charges before
warranty service begins and/or may void this warranty. If any product
accessories (included and/or optional) are shipped with the product, MAGMATIC
and/or the MAGMATIC Authorized Service Center shall have no liability what so
ever for the loss and/or damage to any such accessories, nor the safe return
thereof. If the requested warranty repairs or service (including parts
replacement) are within the terms of this warranty, MAGMATIC will pay return
ground transportation shipping charges to a single designated point within the
United States.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Magmatic Effects is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the informa- tion printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufac-turer’s warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED. THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY DO NOT PLUG THIS UNIT INTO A DIMMER PACK DO NOT REMOVE THE COVER UNDER ANY CONDITIONS KEEP UNIT IN AN UPRIGHT POSITION NEVER OPERATE THIS UNIT WITH THE COVER REMOVED UNPLUG FROM POWER DURING LONG PERIODS OF NON-USE ENSURE TANK IS EMPTY BEFORE STORAGE OR TRANSPORT DO NOT MOVE WHEN FILLED WITH FLUID DISCONNECT POWER BEFORE ADDING FLUID OR PERFORMING MAINTENANCE FOR USE IN INDOOR / DRY LOCATIONS ONLY DO NOT EXPOSE DEVICE TO RAIN AND/OR MOISTURE PLACE UNIT IN A WELL VENTILATED AREA ALLOW 40” (100CM) ABOVE AND AROUND THE UNIT FOR PROPER VENTILATION.
SAFETY GUIDELINES
IMPORTANT SAFETY INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE USE,
AND SAVE THEM FOR FUTURE REFERENCE.
CAUTION
- Risk of burn, fire, or electric shock.
- For indoor use only.
- Please read the instruction manual carefully before use.
- Do not immerse in liquid.
- Not for space heating use.
WARNING : To prevent risk of personal injury, fire, and electric shock:
- Never leave unit unattended while plugged in. Unplug device when not in use.
- Read all important safety instructions and cautions before attempting to use.
- Connect only to a properly grounded power outlet.
- Place product on a flat, level, HARD surface and connect the cord to prevent the product from tip-ping or overturning.
- For use in covered areas only! Keep unit dry, and do not expose to rain, moisture, or liquid immer-sion.
- Leave enough space for adequate ventilation. Keep the device cool and away from other objects.
- Do not operate the device without fog liquid in the reservoir.
- Use caution when filling the fluid reservoir in order to avoid spillage, as spilled liquid can result in electrical shock.
- Do not use if liquid spills into or onto the unit, and allow the device to dry completely before at-tempting usage.
- Do not overfill the fluid reservoir.
- Keep away from flames and flammable or explosive substances.
- Never pour flammable liquids, such as gas, perfume, etc, into the fog machine.
- Keep the device and fog fluid out of reach of children.
- Use only under adult supervision.
- Do not direct fog output in the direction of people or open flame.
- Stay at least 20 inches (50cm) from the output nozzle on the front of the unit.
- Do not obstruct the output nozzle.
- Do not open the unit for any reason. There are no user serviceable parts inside, and all maintenance and repair procedures should be referred to an authorized vendor or technician.
- Only a certified electrician may replace the power cord.
- Clean the unit prior to storage to avoid damage.
POWER SUPPLY CORD
- A short power supply cord (or short detachable power-supply cord) is provided to reduce the risk of a person becoming entangled in or tripping over the cord.
- Extension cords (or long detachable power-supply cords) are available and may be used as long as care is exercised during use.
- If an extension cord (or long detachable power-supply cord) is used, follow the guidelines below:
- The indicated electrical rating of the cord should be meet or exceed the rating of the device.
- If the device is of the grounded type, the cord must use a grounding type 3-wire cord.
- The cord should be routed in such a way as not to cause a tripping hazard or result in uninten-tional snagging or pulling of the cord, especially in the presence of children.
OVERVIEW
- Power In
- Breaker
- DMX In
- DMX Out
- Wired Remote Port
- Touch Display Screen
- Safety Cable Attachment
- Carry Handles (x2)
- LED Array
- Fog Outlet
- Mounting Clamp Points (x4)
- Tank Level Gauge
- Latch Screw
- Tank Access Panel
OPERATION
- When first unboxing, open the shipping carton and carefully remove the device. Be sure to remove ALL the packing material, paying particular attention to the area around the fog outlet vent.
- Always set up the device on a flat dry surface.
- Make sure that the unit is disconnected from power before adding any fluid to the tank.
- To access the fluid tank, unscrew the latch screw that is located on the back side of the unit, near the printed notice about the tank fluid, then open the access panel.
- To fill the tank, remove the tank from behind the tank access panel. Unscrew the tank cap and fill with MAGMATIC ATMOSITY fluid (SKU# AFF only), then replace the cap.
- Never run the device on anything other than an approved, MAGMATIC branded fluid, as doing so can result in severe damage to your device.
- When placing the tank back behind the access panel, be careful not to pinch, twist, or tangle the feed tube connected to the tank cap.
- To close and secure the tank access panel, tighten the latch screw by pushing it down while rotating.
- After re-connecting the device to a power source and switching it on, allow the fluid to warm up for at least nine (9) minutes before beginning fog emission.
PLEASE NOTE
While the fog duration setting can be set as high as 250 seconds, the
individual bursts of continuous fog output will only occur for a maximum of 8
seconds. For example, when the user sets a duration of 250 seconds, this does
NOT mean that the device will be emitting fog continuously for the entire
250-second period. Rather, the device will produce a series of shorter fog
bursts, each lasting up to 8 seconds, throughout the 250-second period.
CONTROL PANEL
This fixture includes a system menu with an easy to navigate touch screen
control panel where all nec-essary settings and adjustments are made. When
first powering on the fixture, the fixture’s main menu will be displayed (see
Main Menu Screen below).
Press the main menu icon you would like to access. Use the ENTER button to
access sub menus and use the UP and DOWN buttons to make adjustments. Press
the ENTER button to confirm your adjust-ments. You may exit the main menu at
any time without making any adjustments by pressing the BACK/EXIT button.
SYSTEM MENU
|
DMX SET
| DMX ADDR| 1 – 512| |
---|---|---|---|---|---
DMX MODE
| 1-CH| |
4-CH| |
7-CH| |
|
PERSONAL- ITY
|
MagApp Set
| MagApp Name| |
MagApp Pass- code| |
MagApp IP| |
MagApp Port| |
MagAppReset
| Complete|
Failed, try again|
MagApp > DMX & Magfly
|
On / Off
| Allows APP data to be converted to DMX data and then sent out via DMX port and Magfly
LCD Set
|
Screen OFF
| Never|
10s|
40s|
1 min|
2 min|
5 min|
10 min|
20 min|
Display Flip| 0 deg / 180 deg|
Magfly Set
| Magfly Channel| 0 – 14| When Magfly is not equipped, selecting this function causes “Optional Mod- ule Not Installed” to show on the screen.
Magfly
|
ON / OFF
CONTINUED ON NEXT PAGE
SYSTEM MENU
|
PERSONAL- ITY
(cont’d from prev page)
|
MagRF Learn
| Frequency Matching fea- ture.
Display will read “Connected” if connection at- tempt succeeds within 20 seconds. Otherwise, display will read “Connec- tion Failed.”
|
When Magfly is not equipped, select- ing this function causes “Optional Module Not Installed” to show on the screen.
---|---|---|---|---
Last State
|
Yes / No
| When powered up, device adheres to last settings used before power was shut off
Default
|
Yes / No
|
Restore to factory settings
|
MANUAL
| | LED Off|
Auto 1-4
Color 1-50
|
Intensity 0% – 100%
|
TIMER
| Interval| 0 – 2500 s|
Start or pause device operation according to these values by pressure the Play/Stop icon.
Duration| 0 – 250 s
| LED Off
Auto 1-4
Color 1-50
|
Intensity 0% – 100%
|
PRESET
|
OPT Effect
| OPT1|
Adjusts fog hang time.
OPT2
OPT3
OPT4
CONTINUED ON NEXT PAGE
|
PRESET
(cont’d from prev page)
|
LED Status
| On| LED on
---|---|---|---|---
Follow| LED illuminates in sync with fog output
Off| LED off
LED Bright| 0% – 100%|
LED Effect
| Off|
Special effects
Random
Pulse
Strobe
LED Style
| LED Off|
Manual fogging effects
Auto 1-4
Color 1-50
MagRF1 Style
| LED Off|
Wireless Remote Button A
Auto 1-4
Color 1-50
MagRF2 Style
| LED Off|
Wireless Remote Button B
Auto 1-4
Color 1-50
MagRF3 Style
| LED Off|
Wireless Remote Button C
Auto 1-4
Color 1-50
MagRF4 Style
| LED Off|
Wireless Remote Button D
Auto 1-4
Color 1-50
|
INFORMATION
| State| Normal / Error|
Slot 1
| Null|
MagFly|
MagApp|
MagRF|
Slot 2
| Null|
MagFly|
MagApp|
MagRF|
CONTINUED ON NEXT PAGE
|
INFORMATION
(cont’d from prev page)
|
Last Control
| LCD_auto|
Displays current source of device control
---|---|---|---|---
LCD_manual
DMX
MagApp
MagRF
MagRemote
Error
MagRemote State| Yes / No| Displays whether MagRemote control is connected
MagApp Connect
| Null| No available MagApp source
Phone| Mobile phone MagApp source
Route| Router MagApp source
No| MagApp module not installed
MagApp IP| Display shows “No” if MagApp module is not installed
MagFly CH| 0 – 14|
DMX Addr| 1 – 512|
DMX Mode| 1 / 4 / 7|
Timer Int| 0s – 2500s|
Timer Dur| 0s – 250s|
Heating| 0% – 100%|
Heater State
| Normal|
Error|
No Heat|
LCD Ver| Vx.x|
Sftwr Ver| Vx.x|
CHANNEL| | VALUES| FUNCTION
---|---|---|---
1-CH| 4-CH| 7-CH
1
|
1
|
1
| | Fog
000 – 009| Off
010 – 127| LED On (1-second delay after start of fog burst)
128 – 255| Max Fog Output, LED On
|
2
| | | Macro
000 – 004| LED Off
005 – 154| Macro 1 – Macro 50 (see Macro Table)
155 – 180| Fog burst & lighting display loop (2s cycle)
181 – 205| Fog burst & lighting display loop (1s cycle)
206 – 230| Auto Mode 2
231 – 255| Auto Mode 1
| | 2| 000 – 255| Red, 0% – 100%
| | 3| 000 – 255| Green, 0% – 100%
| | 4| 000 – 255| Blue, 0% – 100%
| | 5| 000 – 255| Amber, 0% – 100%
|
3
|
6
| | Flash
000 – 031| Off
032 – 095| Random Strobe, slow to fast
096 – 159| Pulse, effect in sequence
160 – 255| Strobe effect, slow to fast
|
4
|
7
| | Dimmer
000 – 003| Off
004 – 255| Dimmer, 1% to 100%
MACRO TABLE
MACRO NO. | DMX VALUES | MACRO NO. | DMX VALUES |
---|---|---|---|
1 | 005 – 007 | 26 | 080 – 082 |
2 | 008 – 010 | 27 | 083 – 085 |
3 | 011 – 013 | 28 | 086 – 088 |
4 | 014 – 016 | 29 | 089 – 091 |
5 | 017 – 019 | 30 | 092 – 094 |
6 | 020 – 022 | 31 | 095 – 097 |
7 | 023 – 025 | 32 | 098 – 100 |
8 | 026 – 028 | 33 | 101 – 103 |
9 | 029 – 031 | 34 | 104 – 106 |
10 | 032 – 034 | 35 | 107 – 109 |
11 | 035 – 037 | 36 | 110 – 112 |
12 | 038 – 040 | 37 | 113 – 115 |
13 | 041 – 043 | 38 | 116 – 118 |
14 | 044 – 046 | 39 | 119 – 121 |
15 | 047 – 049 | 40 | 122 – 124 |
16 | 050 – 052 | 41 | 125 – 127 |
17 | 053 – 055 | 42 | 128 – 130 |
18 | 056 – 058 | 43 | 131 – 133 |
19 | 059 – 061 | 44 | 134 – 136 |
20 | 062 – 064 | 45 | 137 – 139 |
21 | 065 – 067 | 46 | 140 – 142 |
22 | 068 – 070 | 47 | 143 – 145 |
23 | 071 – 073 | 48 | 146 – 148 |
24 | 074 – 076 | 49 | 149 – 151 |
25 | 077 – 079 | 50 | 152 – 154 |
DIMENSIONAL DRAWINGS
TROUBLESHOOTING
If you experience low output, pump noise, or no output at all, disconnect the device and discontinue use immediately. Do not attempt to continue operation as this may damage the machine. Check the fluid level, the breaker, and the wall outlet to make sure that it is sending power. If all the above factors do not appear to be causing the issue, and the unit still fails to operate correctly, the unit will require service. Please contact Magmatic Effects for assistance.
CLEANING & MAINTENANCE
When storing your device, be sure to store in a cool area. Cover the device so
that dust does not build up on the device. When storing for long periods of
time it is highly advisable to run the device at least once every 3-4 months.
Long periods of inactivity can severely shorten the life of your device. Only
run Magmatic’s Atmosity fluid (SKU# AFF) through your machine. Never run plain
water, vinegar, or any other liquid solution through your device, as doing so
will severely damage your device.
SPECIFICATIONS
PERFORMANCE
- Rated Power: 1450W
- Max Output: 50,000 CFM* (cu ft/min.)
- Max Continuous Output: 8 Seconds @ Full
- Max Throw Distance: 25 Feet
- Initial Ready Time: 9 Minutes
- Cycling Ready Time: 1 Minute
- Fluid Capacity: 2.5L
- Fluid Consumption: 180ml/min.
COMPATIBLE FLUID
- Atmos Flash Fog Fluid (AFF-4L)
- Atmos Extreme Filtered Fog Fluid (AEF-4L)
CONSTRUCTION
- Thermally Protected Heat Exchanger
- Advanced HPA (high pressure air) Pump Technology Energy Saving Mode with Auto-Clean Process Sealed Fluid
- Reservoir
- External Visual Fluid Level Detection
- Compact Light Weight Mobile Design
CONTROL
- 3 DMX Channel Modes (1 / 4 / 7)
- Onboard LCD Touch Control Panel
- DMX-512 and RDM Protocol Support
- Optional MagFLY Wireless DMX Transceiver
- Optional MagRF and Wired Remotes
CONNECTIONS
- 5-pin locking XLR, In/Out Data Connectors
- IP65 Locking Input Power Connector
- With Wired Digital Communication Network
- SIZE / WEIGHT
- Length: 16.26 in. (413mm)
- Width: 7.60 in. (193mm)
- Height: 14.80 in. (376mm)
- Weight: 29.5 lbs. (13.4kg)
ELECTRICAL
- Input Voltage: 120V, 230V, 240V 50/60Hz
- Resettable Breaker (NFB): 20A (120V) / 10A (230V)
- Max Power Consumption: 1560W
- THERMAL
- Maximum Ambient Temperature (Ta max) 104°F (40°C)
- Exterior Surface Temperature, Steady State: 140°F (60°C)
- APPROVALS / RATINGS
- CE | cETLus (pending) | IP20
MAGFLY MODULE
SPECIFICATIONS
-
2.4 GHz Wireless Frequency
450m Effective Distance (open space with clear line of sight from transmitter to receiver) Wireless DMX Function -
Without Antenna:
Dimensions (LxWxH): 3.1” x 2.2” x 0.8” (80mm x 56mm x 21mm) Weight: 3.2 oz (90g) -
With Long Antenna:
Dimensions (LxWxH): 6.7” x 2.2” x 0.8” (169mm x 56mm x 21mm) Weight: 3.5 oz (98g) -
With Short Antenna:
Dimensions (LxWxH): 3.6” x 2.2” x 0.8” (91mm x 56mm x 21mm) Weight: 3.3 oz (93g)
MAGFLY MODULE
OPERATION
- Attach either of the included antennas to the MagFly module, then locate the card input slots on your Magmatic device. Use a screwdriver to remove the slot cover for one of the input slots, then insert the MagFly module and fasten it in place with the module’s mounting screws.
- Check the display screen on your Magmatic device. The MagFly icon should appear at the top of the screen, as shown below.
- Select the Personality icon on your Magmatic device’s touch screen, then select the “MagFly Set” option to configure your MagFly module. Refer to your the System Menu section of this manual for detailed information.
- Use the UP and DOWN keys to scroll to the “MagFly On/Off” option. Select this option, and switch this setting to ON.
- Return to the “MagFly Set” menu, and use the UP and DOWN keys to scroll to and select the “MagFly Channel” option. Selectable values range from 0 to 14.
- The MagFly module is now configured and ready to use. Please note, the MagFly module auto-matically switches between sending or receiving data, depending on whether a data input signal is detected at the device’s DMX port.
MAGRF MODULE
RECEIVER
SPECIFICATIONS
- 433 MHz Wireless Frequency
- 50m Effective Distance (open space with clear line of sight from transmitter to receiver) Function varies with Magmatic fixture model
- 27A / 12V Transmitter Battery
- Receiver Dimensions (LxWxH): 3.4” x 2.2” x 0.8” (86mm x 56mm x 21mm)
- Receiver Weight: 1.1 oz (32g)
- Transmitter Dimensions (LxWxH): 2.6” x 1.4” x 0.6” (65mm x 36mm x 15mm) Transmitter Weight: 1.3 oz (36g)
MAGRF MODULE
OPERATION
- Locate the card input slots on your Magmatic device. Use a screwdriver to remove the slot cover for one of the input slots, then insert the MagRF module and fasten it in place with the module’s mount-ing screws.
- Check the display screen on your Magmatic device. The Bluetooth icon and the letters “RF” should appear at the top of the screen, as shown below.
- Select the Personality icon on your Magmatic device’s touch screen, then select the “MagRF Learn” option. Press any of the four keys on the transmitter to pair the transmitter. If pairing is successful, a notification reading “Connected” will appear. On the other hand, if no action is taken within 20 sec-onds, or if pairing is unsuccessful, a prompt reading “Connection Failed” will appear.
- After the receiver and transmitter are paired, the transmitter can be used to control the operation of the device. The assigned functions of each of the four keys on the transmitter vary with the particular device model. See your device’s user manual for information.
FCC STATEMENT
This device complies with Part 15 of the FCC rules. Operation is subject to the following two condi-tions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This equipment has been tested and found to comply with the limits for a class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This device uses and can radiate radio fre-quency
energy, and if not installed and used in accordance with the included
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this device does cause harmful interference to radio or
television reception, which can be determined by turning the device off and
on, the user is encouraged to try to correct the interference by one or more
of the following methods:
- Reorient or relocate that device.
- Increase the separation between the device and the receiver.
- Connect the device to an electrical outlet on a circuit different from the one connected to the radio receiver.
- Consult the dealer or an experienced radio/TV technician for help.
Please note that the changes or modifications of this product that are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>