MAGMATIC TST801 Therma Tour 800 Oil-based Haze Effect Generator User Manual
- June 5, 2024
- MAGMATIC
Table of Contents
- **GENERAL INFORMATION
- WARRANTY RETURNS (USA ONLY)
- SAFETY GUIDELINES
- OVERVIEW
- SET UP
- CONTROL PANEL
- SYSTEM MENU
- PRESET MODE
- DMX CHANNEL FUNCTIONS & VALUES
- DIMENSIONAL DRAWINGS
- TROUBLESHOOTING
- CLEANING & MAINTENANCE
- SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
THERMA TOUR 800
User Manual
US SKU# : TST801
UPC#: 810008261552
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of
this document may be available online.
Please check www.elationlighting.com for the
latest revision/update of this manual before beginning installation and/or
programming.
Date| Document Version| Software Version| DMX Channel
Mode| Notes
---|---|---|---|---
09/30/20| 1.0| 1.0| 1 / 3 Channels| Initial Release
12/15/20| 2.0| 1.0| 1 / 3 Channels| Updated Dimensional Drawings &
Specifications
**GENERAL INFORMATION
**
INTRODUCTION
Please read and understand the instructions in this manual carefully and
thoroughly before attempting to operate this device. These instructions
contain important safety and use information. This product is intended to be
used by professionally trained personnel only and is not suitable for private
use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton is damaged, carefully inspect the
device for damage, and be sure all accessories necessary to install and
operate the device have arrived intact. In the event that damage has been
found or parts are missing, please contact our customer support team for
further instructions. Please do not return this device to your dealer without
first contacting customer support. Please do not discard the shipping carton
in the trash. Please recycle whenever possible.
BOX CONTENTS
Twist-locking power cable (x1)
Haze outlet cap (x1)
CUSTOMER SUPPORT
Contact MAGMATIC customer service for any product-related service and support
needs.
Also visit forums.elationlighting.com with questions, comments, or
suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
sales@magmaticeffects.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 63 | Fax: +31 45 546 85 96 |
support@elationlighting.eu
IMPORTANT NOTICE!
THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
NEVER POINT OR AIM A FOG MACHINE TOWARD PEOPLE OR THEIR CLOTHING. THIS UNIT
EMITS HOT VAPOR AND SHOULD BE USED WITH THE SAME CARE THAT YOU WOULD OBSERVE
WHEN USING AN ELECTRIC KETTLE OR IRON.
LIMITED WARRANTY (USA ONLY)
A. Magmatic Effects hereby warrants, to the original purchaser, Magmatic
products to be free of manufacturing defects in material and workmanship for a
period of two years (730 days) from the original date of purchase. This
warranty excludes discharge lamps and all product accessories. This warranty
shall be valid only if the product is purchased within the United States of
America, including possessions and territories. It is the owner’s
responsibility to establish the date and place of purchase by acceptable
evidence, at the time service is sought.
B. For warranty service, send the product only to the Magmatic Effects
factory. All shipping charges must be pre-paid. If the requested repairs or
services (including parts replacement) are within the terms of this warranty,
Magmatic Effects will pay return shipping charges only to a designated point
within the United States. If any product is sent, it must be shipped in its
original package and packaging material. No accessories should be shipped with
the product. If any accessories are shipped with the product, Magmatic
Effects shall have no liability whatsoever for loss and/or damage to any such
accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are
altered or removed; if the product is modified in any manner that Magmatic
Effects concludes, after inspection, affects the reliability of the product;
if the product has been repaired or serviced by anyone other than the Magmatic
Effects factory unless prior written authorization was issued to purchaser by
Magmatic Effects; if the product is damaged because not properly maintained as
set forth in the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any
maintenance, cleaning or periodic check-up. During the periods as specified
above, Magmatic Effects will replace defective parts at its expense and will
absorb all expenses for warranty service and repair labor by reason of defects
in material or workmanship. The sole responsibility of Magmatic Effects under
this warranty shall be limited to the repair of the product, or replacement
thereof, including parts, at the sole discretion of Magmatic
Effects. All products covered by this warranty were manufactured after January
1, 1990, and bear identifying marks to that effect.
E. Magmatic Effects reserves the right to make changes in design and/or
performance improvements upon its products without any obligation to include
these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to
any accessory supplied with the products described above. Except to the extent
prohibited by applicable law, all implied warranties made by Magmatic Effects
in connection with this product, including warranties of merchantability or
fitness, are limited in duration to the warranty periods set forth above. And
no warranties, whether expressed or implied, including warranties of
merchantability or fitness, shall apply to this product after said periods
have expired. The consumer’s and/or dealer’s sole remedy shall be such repair
or replacement as is expressly provided above; and under no circumstances
shall Magmatic Effects be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this
product.
G. This warranty is the only written warranty applicable to Magmatic Effects
products and supersedes all prior warranties and written descriptions of
warranty terms and conditions heretofore published.
WARRANTY RETURNS (USA ONLY)
To obtain warranty service, a Return Material Authorization (RMA) number must
first be obtained from MAGMATIC. It is the Customer’s responsibility to
provide product proof of purchase and serial number by acceptable evidence
such as an invoice copy or an approved MAGMATIC Extended Warranty Certificate
(“EWC”) and any relevant maintenance records at the time warranty service is
sought. Failure to provide acceptable evidence of product proof of purchase or
EWC and any relevant maintenance
records may be cause for denial of warranty service.
Products returned for warranty service must be sent without any accessories
(i.e., power, data, and safety cables, brackets, clamps, rigging hardware,
frost filters, gel frames, barn doors, lenses, hoses, nozzles, rack mounting
hardware, etc.), must be boxed using the original and/or suitable packaging
materials (double-box and foam) that provides ample
product protection for ground and/or air freight transit, and must be shipped
freight pre-paid and insured to MAGMATIC in Los Angeles, CA or a MAGMATIC
Authorized Service Center. The RMA number must be clearly written on the
outside of the return box, and a brief description of the problem and the RMA
number must be documented and included in the box. Products returned for
warranty service without an RMA number clearly marked on the outside of the
package will be refused and returned to the hipper at the Customer’s expense.
Products returned for warranty service, which are received damaged due to
inadequate and/or improper packaging and/or due to damage caused by the
shipping carrier, may incur additional repair charges before warranty service
begins and/or may void this warranty. If any product accessories (included
and/ or optional) are shipped with the product, MAGMATIC and/or the MAGMATIC
Authorized Service Center shall have no liability whatsoever for the loss
and/or damage to any such accessories, nor the safe return thereof. If the
requested warranty repairs or service (including parts replacement) are within
the terms of this warranty, MAGMATIC will pay return ground transportation
shipping charges to a single designated point within the United States.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Magmatic Effects is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform the installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED.
THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S
WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND/OR THE
DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE
MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR
REPAIRS.
DO NOT PLUG THIS UNIT IN TO A DIMMER PACK DO NOT REMOVE THE COVER UNDER ANY
CONDITIONS KEEP THE UNIT IN AN UPRIGHT POSITION NEVER OPERATE THIS UNIT WITH
THE COVER REMOVED UNPLUG FROM POWER DURING LONG PERIODS OF NON-USE ENSURE THE
TANK IS EMPTY BEFORE STORAGE OR TRANSPORT DO NOT MOVE WHEN FILLED WITH FLUID
DISCONNECT POWER BEFORE ADDING FLUID OR PERFORMING MAINTENANCE
FOR USE IN INDOOR / DRY LOCATIONS ONLY DO NOT EXPOSE THE DEVICE TO RAIN AND/OR
MOISTURE PLACE UNIT IN A WELL-VENTILATED AREA ALLOW 40” (100CM) ABOVE AND
AROUND THE UNIT FOR PROPER VENTILATION.
SAFETY GUIDELINES
- CAUTION: Fog machines may set off smoke alarms!
- Do not attempt installation and/or operation of this device without proper knowledge of how to do so.
- Do not point or direct fog output in an unsafe direction.
- Do not touch the front nozzle while the machine is in operation, or immediately after the device has been shut down, as the nozzle may get hot during operation.
- Do not shake device, and avoid brute force when installing and/or operating.
- Be sure to save the packing carton in the unlikely event the device may have to be returned for service.
- Do not spill water or other liquids into or on to the device. Be sure that all the fog fluid is kept inside the fluid reservoir.
- Be sure that the local power outlet matches the required voltage for the device.
- Do not remove components or disassemble the device. There are no user-serviceable parts inside.
- Never connect this device to a dimmer pack.
- Do not attempt to operate this device if it has been damaged in any way.
- Never use this device with the cover removed.
- To reduce the risk of electrical shock or fire, do not expose this device to rain or moisture.
- Do not attempt to operate this device if the power cord has been frayed, crimped, and/or damaged. Replace any damaged power cords with new cords of the same power rating.
- Do not remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
- Always disconnect from the main power before making any connection, performing cleaning or maintenance, or adding or draining water.
- Always drain the fluid before moving the device.
- Always be sure to mount this device in an area that will allow proper ventilation.
- Always disconnect power cords during long periods of non-use.
- This unit is intended for indoor use only. Use of this product outdoors voids all warranties.
- Always mount this unit in a safe and stable matter.
- Please route your power cord out of the way of foot traffic. Power cords should be routed so they are not likely to be walked on, or pinched by items placed upon or against them.
- The device should be serviced by qualified service personnel when:
- The power cords or plugs have become damaged.
- Objects have fallen on and/or liquid has spilled into the device.
- The device has been exposed to rain and/or moisture.
- The device does not operate normally or exhibits a marked change in performance.
OVERVIEW
1. Control Panel Lid
2. Haze Outlet/Filler Lid
3. Directional Blower
4. Haze Outlet w/ Cap
5. Tank Fill
6. Tank Level Gauge
7. Power In| 8. Breaker
9. Power Switch
10. Cooling Vent
11. DMX In
12. DMX Out
13. Wired Remote Port
14. Touch Display Screen
---|---
SET UP
- Open the shipping carton and carefully remove the device from the shipping carton.
- Be sure to remove ALL the packing material, paying particular attention to the area around the fog outlet vent.
- Set the device on a flat dry surface. Open the filler/outlet lid and unscrew the tank fill cap.
- Fill the tank only with approved ATMOSITY fluid (SKU# ARH and AAH only), and replace the reservoir cap. Never run the device on anything other than an approved, MAGMATIC branded fluid, as doing so can result in severe damage to your device.
- Plug the device into a matching power supply and flip the power switch to the ON position.
- After power is switched on, the device is immediately ready to emit haze. The device may be controlled manually or via a DMX signal.
CONTROL PANEL
This unit includes a system menu with an easy-to-navigate touch screen control
panel where all necessary settings and adjustments are made. When first
powering on the machine, the main menu will be displayed (see Main Menu Screen
below).
Press the main menu icon you would like to access. Use the ENTER button to
access the sub-menus and use the UP and DOWN buttons to make adjustments.
Press the ENTER button to confirm your adjustments. You may exit to the main
menu at any time without making any adjustments by pressing the BACK/EXIT
button.
After 10 seconds of non-operation, the system will return to the “Ready to
Fog” status screen.
SYSTEM MENU
| DMX SET| DMX ADDRESS| 1 – 512| |
---|---|---|---|---|---
DMX MODE| 1-CH| |
3-CH| |
| PERSONALITY| WiFi Set| Wifi Name| |
Wifi Passcode| |
Wifi IP| |
Wifi Port| |
Reset Network
| Connected|
Failed, try again|
Wifi > DMX & Magfly| On / Off| Allows APP data to be converted to DMX data and
then sent out via DMX port and Mayfly
LCD Set| Screen OFF| Never|
10s|
The 40s|
1 min|
2 min|
5 min|
10 min|
20 min|
Magfly Set| Magfly Channel| 0 – 14| When Magfly is not equipped, selecting
this function causes “Optional Module Not Installed” to show on the screen.
Mayfly| ON / OFF
MagRF Learn| Frequency Matching feature. The display will read “Connected” if
the connection attempt succeeds within 20 seconds. Otherwise, the display will
read “Connection Failed.”| When Magfly is not equipped, selecting this
function causes “Optional Module Not Installed” to show on the screen.
CONTINUED ON NEXT PAGE
| PERSONALITY
(cont’d from prev page)
| Last State| Yes / No| When powered up, device adheres to last settings used
before power was shut off
---|---|---|---|---
Default| Yes / No| Restore to factory settings
| MANUAL| | Fog Output 0 – 100%| Start or pause device operation
according to these values by pressuring the Play/Start icon.
| Wind Intensity 0 – 100%
| TIMER| Interval| 0 – 2500 s| Start or pause device operation according
to these values by pressuring the Play/Start icon.
Duration| 0 – 250 s
| PRESET| Preset 1| See the PRESET MODE section for details.
Preset 2
Preset 3
Preset 4
Preset 5
| INFORMATION| State| Normal / Error| |
Slot 1| Null| |
Mayfly| |
Wifi| |
MagRF| |
Slot 2| Null| |
Mayfly| |
Wifi| |
MagRF| |
CONTINUED ON NEXT PAGE
| INFORMATION
(cont’d from prev page)
| Last Control| LCD_auto| Displays current control mode.
---|---|---|---|---
LCD_manual
DMX
Wifi
MagRF
MagRemote
Error
Remote State| Yes / No| Displays whether the remote is connected or not.
Wifi Connect| Null| No source available for Wifi connection
Phone| Mobile phone
Route| Router
No| Wifi module is not connected
Wifi IP| The display reads “NO” if Wifi module is not connected.
Mayfly CH| 0 – 14| |
DMX Address| 1 – 512| |
DMX Mode| 1 / 3 CH| |
Timer Output| 0 – 100%| |
Timer Wind| 0 – 100%| |
Timer Int.| 0 – 2500 s| |
Timer Dur.| 0 – 250 s| |
No Fluid| Normal / Empty| Normal indicates enough fluid in tank for
operation. Empty indicates fluid refill is required.
LCD Ver.| V1.1| |
Sftwr Ver.| V1.0| |
PRESET MODE
Preset Mode| Duration| Interval| Fog Output| Wind
Intensity
---|---|---|---|---
1| 40 min| 20 min| 100%| 100%
2| 30 min| 15 min| 100%| 100%
3| 20 min| 10 min| 100%| 100%
4| 10 min| 5 min| 100%| 100%
5| 5 min| 5 min| 100%| 100%
DMX CHANNEL FUNCTIONS & VALUES
CHANNEL | VALUES | FUNCTION |
---|---|---|
1-CH | 3-CH |
1
| ****
1
| | Fog
000 – 005| Off
006 – 255| On
| ****
2
| | Duration
000 – 005| Off (0s)
006 – 255| On, 1s – 250s (steps of 1s)
| ****
3
| | Interval
000 – 005| Off (0s)
006 – 255| On, 10s – 2500s (steps of 10s)
DIMENSIONAL DRAWINGS
Dimensions may not be drawn to scale.
TROUBLESHOOTING
If you experience low output, pump noise, or no output at all, disconnect the device and discontinue use immediately. Do not attempt to continue operation as this may damage the machine. Check the fluid level, the breaker, and the wall outlet to ensure it is sending power. If all the above factors do not appear to be causing the issue, and the unit still fails to operate correctly, it will require service. Please contact Magmatic Effects for assistance.
CLEANING & MAINTENANCE
When storing your device, be sure to store in a cool area. Cover the device so that dust does not build up on the device. It is highly advisable to run the machine at least once every 3-4 months when storing for long periods of time. Long periods of inactivity can severely shorten the life of your device. Only run Magmatic’s Atmosity fluid (SKU# ARH or AAH) through your machine. Never run plain water, vinegar, or any other liquid solution through your device, as doing so will severely damage your device.
SPECIFICATIONS
KEY FEATURES
800 Watt low power consumption
Over 35 hours of run time
Haze lasting up to 3 hours after the machine is off
Rugged mobile road case design
Soundproof insulation for indoor use| SIZE / WEIGHT
Length: 24.45 in. (621.13mm)
Width: 15.34 in. (389.63mm)
Height: 19.87 in. (504.76mm with wheel)
Weight: 93 lbs. (42kg)
---|---
DYNAMIC EFFECTS
Output: 5600 cu.ft / Min
External Visual Fluid Level Detection| ELECTRICAL
Power Consumption: 820w
Input Voltage: 120V 60Hz, 230V 50Hz
Breaker Size: 15A (120V version)
Breaker Size: 10A (230V version)
COMPATIBLE FLUID
Atmos ARH (Oil-based fluid)| THERMAL
Maximum Temperature (Ambient): 104°F (40°C)
Exterior Surface Temperature: 122°F (50°C)
CONSTRUCTION / PHYSICAL / PERFORMANCE
External Visual Fluid Level Detection
Fluid Tank Capacity: 2.5L
Fluid Consumption: 1.5ml / Min.| OPTIONAL ACCESSORIES
MagFly
MagRF
CONTROL
2 Card Inputs
RDM (Remote DMX)
Control Protocol: DMX
DMX Channels: 1,3
DMX Modes: 2
On-Board Timing Control
5 Factory Presets
4-Pin Wired Remote Input
Touch Screen Display
Manual Hazing| APPROVALS / RATINGS
CE | cETLus | IP20
CONNECTIONS
Data Connectors: 5-Pin XLR/Out, 4-Pin XLR Out
Locking Power Connector|
Specifications and documentation subject to change without notice.
FCC S STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This equipment has been tested and found to comply with the limits for a class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This device uses and can radiate radio frequency
energy and, if not installed and used in accordance with the included
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this device does cause harmful interference to radio or
television reception, which can be determined by turning the device off and
on, the user is encouraged to try to correct the interference by one or more
of the following methods:
- Reorient or relocate the device.
- Increase the separation between the device and the receiver.
- Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Please note that the changes or modifications of this product is not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
©2020 MAGMATIC EFFECTS all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without
notice. MAGMATIC EFFECTS logo and identifying product names and numbers herein
are trademarks of MAGMATIC EFFECTS. Copyright protection claimed includes
all forms and matters of copyrightable materials and information now allowed
by statutory or judicial law or hereinafter granted. Product names used in
this document may be trademarks or registered trademarks of their respective
companies and are hereby acknowledged. All non-MAGMATIC brands and product
names are trademarks or registered trademarks of their respective companies.
MAGMATIC EFFECTS and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
MAGMATIC EFFECTS
| 6122 S. Eastern Ave. |
Los Angeles, CA. 90040323-582-3322 |
323-832-9142 fax
|www.elationlighting.com |
sales@magmaticeffects.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade,
The Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax
|www.elationlighting.eu |
info@elationlighting.eu
Elation Professional Mexico
| AC Santa Ana 30 | Parque Industrial Lerma,
Lerma, Mexico 52000
+52728-282-7070
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>