MAGMATIC Therma Tour 600 Premium Oil Based Haze Effect Generator User Manual
- June 5, 2024
- MAGMATIC
Table of Contents
- MAGMATIC Therma Tour 600 Premium Oil Based Haze Effect Generator
- GENERAL INFORMATION
- LIMITED WARRANTY (USA ONLY)
- SAFETY GUIDELINES
- OVERVIEW
- SET UP
- CONTROL PANEL
- SYSTEM MENU
- PRESET MODE
- DMX CHANNEL FUNCTIONS & VALUES
- DIMENSIONAL DRAWINGS
- TROUBLE SHOOTING
- CLEANING & MAINTENANCE
- SPECIFICATIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MAGMATIC Therma Tour 600 Premium Oil Based Haze Effect Generator
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contains important safety and use information. This product is intended to be used by professionally trained personnel only, and is not suitable for private use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Care-fully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and operate the device have arrived intact. In the event that damage has been found or parts are missing, please contact out customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.
BOX CONTENTS
Twist-locking power cable
CUSTOMER SUPPORT
Contact MAGMATIC customer service for any product related service and
support needs.
Also visit forums.elationlighting.com with questions, comments, or
suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
sales@magmaticeffects.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 63 | Fax: +31 45 546 85 96 | support@elationlighting.eu
REPLACEMENT PARTS: Please visit
parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAM-AGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
NEVER POINT OR AIM A FOG MACHINE TOWARDS PEOPLE OR THEIR CLOTHING. THIS UNIT
EMITS HOT VAPOR AND SHOULD BE USED WITH THE SAME CARE THAT YOU WOULD OBSERVE
WHEN USING AN ELECTRIC KETTLE OR IRON.
LIMITED WARRANTY (USA ONLY)
- Magmatic Effects hereby warrants, to the original purchaser, Magmatic products to be free of manufacturing defects in material and workmanship for a period of two years (730 days) from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
- For warranty service, send the product only to the Magmatic Effects factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Magmatic Effects will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Magmatic Effects shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof.
- This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Magmatic Effects concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Magmatic Effects factory unless prior written authorization was issued to purchaser by Magmatic Effects; if the product is damaged because not properly maintained as set forth in the product instructions, guide-lines and/or user manual.
- This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Magmatic Effects will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Magmatic Effects under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Magmatic Effects. All products covered by this warranty were manufactured after January 1, 1990, and bear identifying marks to that effect.
- Magmatic Effects reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
- No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Magmatic Effects in connection with this product, including warranties of merchant-ability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Magmatic Effects be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
- This warranty is the only written warranty applicable to Magmatic Effects products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
To obtain warranty service, a Return Material Authorization (RMA) number must first be obtained from MAGMATIC. It is the Customer’s responsibility to provide product proof of purchase and serial number by acceptable evidence such as an invoice copy or an approved MAGMATIC Extended Warranty Certificate (“EWC”) and any relevant maintenance records at the time warranty service is sought. Failure to provide acceptable evidence of product proof of purchase or EWC and any relevant maintenance records may be cause for denial of warranty service. Products returned for warranty service must be sent without any accessories (i.e., power, data, and safety cables, brackets, clamps, rigging hardware, frost filters, gel frames, barn doors, lenses, hoses, nozzles, rack mounting hardware, etc.), must be boxed using the original and/or suitable packaging materials (double-box and foam) that provides ample product protection for ground and/or air freight transit, and must be shipped freight pre-paid and insured to MAGMATIC in Los Angeles, CA or a MAGMATIC Authorized Service Center. The RMA number must be clearly written on the outside of the return box, and a brief description of the problem and the RMA number must be documented and included in the box. Products returned for warranty service without an RMA number clearly marked on the outside of the package will be refused and returned to the shipper at the Customer’s expense. Products returned for warranty service, which are received damaged due to inadequate and/or improper packaging and/or due to damage caused by the shipping carrier, may incur additional repair charges before warranty service begins and/or may void this warranty. If any product accessories (included and/or optional) are shipped with the product, MAGMATIC and/or the MAGMATIC Authorized Service Center shall have no liability what so ever for the loss and/or damage to any such accessories, nor the safe return thereof. If the requested warranty repairs or service (including parts replacement) are within the terms of this warranty, MAGMATIC will pay return ground transportation shipping charges to a single designated point within the United States.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Magmatic Effects is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the informa- tion printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufac-turer’s warranty and increase the risk of damage and/or personal injury.
-
PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED.
-
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO
-
NOT ATTEMPTS ANY REPAIRS YOURSELF. DOING SO WILL VOID
-
YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND/OR THE DISREGARD OF
SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY -
DO NOT PLUG THIS UNIT INTO A DIMMER PACK
-
DO NOT REMOVE THE COVER UNDER ANY CONDITIONS
-
KEEP UNIT IN AN UPRIGHT POSITION
-
NEVER OPERATE THIS UNIT WITH THE COVER REMOVED
-
UNPLUG POWER DURING LONG PERIODS OF NON-USE
-
ENSURE TANK IS EMPTY BEFORE STORAGE OR TRANSPORT
-
DO NOT MOVE WHEN FILLED WITH FLUID
-
DISCONNECT POWER BEFORE ADDING FLUID OR PERFORMING MAINTENANCE
-
FOR USE IN INDOOR / DRY LOCATIONS ONLY
-
DO NOT EXPOSE DEVICE TO RAIN AND/OR MOISTURE
-
PLACE UNIT IN A WELL VENTILATED AREA
-
ALLOW 40” (100CM) ABOVE AND AROUND THE UNIT FOR PROPER VENTILATION.
CAUTION: Fog machines may set off smoke alarms!
- Do not attempt installation and/or operation of this device without proper knowledge of how to do so.
- Do not point or direct fog output in an unsafe direction.
- Do not touch the front nozzle while the machine is in operation, or immediately after the device has been shut down, as the nozzle may get hot during operation.
- Do not shake device, and avoid brute force when installing and/or operating.
- Be sure to save the packing carton in the unlikely event the device may have to be returned for service.
- Do not spill water or other liquids into or on to the device. Be sure that all the fog fluid is kept inside the fluid reservoir.
- Be sure that the local power outlet matches the required voltage for the device.
- Do not remove components or disassemble the device. There are no user-serviceable parts inside.
- Never connect this device to a dimmer pack.
- Do not attempt to operate this device if it has been damaged in any way.
- Never use this device with the cover removed.
- To reduce risk of electrical shock or fire, do not expose this device to rain or moisture.
- Do not attempt to operate this device if the power cord has been frayed, crimped, and/or damaged. Replace any damaged power cords with new cords of the same power rating.
- Do not remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
- Always disconnect from main power before making any connection, performing cleaning or maintenance, or adding or draining water.
- Always drain fluid before moving the device.
- Always be sure to mount this device in an area that will allow proper ventilation.
- Always disconnect power cords during long periods of non-use.
- This unit is intended for indoor use only. Use of this product outdoors voids all warranties.
- Always mount this unit in a safe and stable matter.
- Please route your power cord out of the way of foot traffic. Power cords should be routed so they are not likely to be walked on, or pinched by items placed upon or against them.
- The device should be serviced by qualified service personnel when:
- The power cords or plugs have become damaged.
- Objects have fallen on and/or liquid has spilled into the device.
- The device has been exposed to rain and/or moisture.
- The device does not operate normally or exhibits a marked change in performance.
OVERVIEW
- Directional Blower
- Tank
- Haze Outlet w/ Cap
- Tank Level Gauge
- Haze Outlet/Filler Lid
- Control Panel Lid
- Breaker
- Power Input
- DMX Input
- DMX Output
- Cooling Vent
- Power Switch
- Wired Remote Port
- Touch Display Screen
SET UP
- Open the shipping carton and carefully remove the device from the shipping carton.
- Be sure to remove ALL the packing material, paying particular attention to the area around the fog outlet vent.
- Set the device on a flat dry surface. Open the filler/outlet lid and unscrew the tank filler cap.
- Fill the reservoir with MAGMATIC ATMOSITY fluid (SKU# ARH and AAH) only, and replace the reservoir cap. Never run the device on anything other than an approved, MAGMATIC branded fluid, as doing so can result in severe damage to your device.
- Plug the device into a matching power supply and flip the power switch to the ON position.
- After power is switched on, the device is immediately ready to emit haze. The device may be controlled manually or via DMX signal.
CONTROL PANEL
This fixture includes a system menu with an easy to navigate touch screen
control panel where all ne-essary settings and adjustments are made. When
first powering on the fixture, the fixture’s main menu will be displayed (see
Main Menu Screen below).
Press the main menu icon you would like to access. Use the ENTER button to
access sub menus and use the UP and DOWN buttons to make adjustments. Press
the ENTER button to confirm your adjus-ments. You may exit the main menu at
any time without making any adjustments by pressing the BACK/EXIT button.
After 10 seconds of non-operation, the system will return to the “Ready to
Fog” status screen.
SYSTEM MENU
| DMX SET| DMX Addr| 1 – 512| Set DMX address
---|---|---|---|---
| DMX Mode| 1-CH| Set DMX mode
| 3-CH
| PERSONALITY| Wifi Set*| Wifi Name| 0 – xxxxx| Displays name of Wifi
connection
|
Wifi Passcode
| 00000000 –
00009999
| First 4 digits of passcode must be “0000”
| Wifi IP| 0~255 . 0~255 .
0~255 . 0~255
| Wifi IP address
| Wifi Port| 0 – 65535| Network port
|
Reset Network
| Complete| Wifi paired success- fully within 5s
| Failed, try again| Wifi not paired within 5s
| Wifi -> DMX & Magfly| On / Off| Enable/disable APP data to be con- verted to
DMX data and sent out via DMX port and EFly. Please switch off when not in
use.
| LCD Set| Screen Off| Never| Screen switches off after designated period of
inactivity
| 10s
| 40s
| 1min
| 2min
| 5min
| 10min
| 20min
|
Magfly Set*
| Magfly Channel| 0 – 14| Magfly channel set- ting
| Magfly| On / Off| Magfly switch
| MagRF Learn*| Connected| Frequency match- ing successful within 20s
| Connection Failed| Frequency match- ing not successful within 20s
| CONTINUED ON NEXT PAGE
PERSONALITY
(continued)
|
Last State
|
Yes / No
| Define whether device stays at the last step|
Default
|
Yes / No
| Restore device to default factory set- tings|
MANUAL| Fog (100%)| Start or stop using the triangle icon. Note that
both Fog and Wind are fixed at 100%|
Wind (100%)|
TIMER| Interval| 0s – 2500s|
Start or stop using the triangle icon. Note that both Fog and Wind are fixed at 100%
|
Duration| 0s – 250s|
PRESET| Preset 1: Duration: 40min Interval: 20min Fog: 100%
Wind:100%
| Start or stop using the triangle icon. Note that both Fog and Wind are
fixed at 100%|
Preset 2: Duration: 30min Interval: 15min Fog: 100%
Wind:100%
|
Preset 3: Duration: 20min Interval: 10min Fog: 100%
Wind:100%
|
CONTINUED ON NEXT PAGE|
|
PRESET
(continued)
| Preset 4: Duration: 10min Interval: 5min Fog: 100%
Wind:100%
|
Start or stop using the triangle icon. Note that both Fog and Wind are fixed at 100%
|
| Preset 5: Duration: 5min Interval: 5min Fog: 100%
Wind:100%|
| INFORMATION| State| Normal / Error| Shows operational status of
device|
|
Slot 1
|
Null / Magfly / Wifi / MagRF
| Shows type of module fitted to slot 1; “Null” signifies no module fitted|
|
Slot 2
|
Null / Magfly / Wifi / MagRF
| Shows type of mod- ule fitted to slot 2; ”Null” signifies no module fitted|
| Last Control| LCD_auto / LCD_manual / DMX / Wifi / MagRF / MagRemote /
Error| Display current means of control|
| Remote State| Yes / No| Shows whether re- mote is connected|
|
Wifi Connect
|
Null / Phone / Route / No
| Display the type of device that Wifi has connected to; “No” signifies Wifi
mod- ule not connected, and “Null” signifies that module has failed to find a
de- vice to connect to|
| Wifi IP| No / 0-255, 0-255, 0-255, 0-255| Current IP address; “No” signifies
Wifi module is not con- nected|
| Magfly Ch.| 0 – 14| Magfly channel|
| DMX Addr| 1 – 512| DMX address|
| DMX Mode| 1 / 3| DMX mode|
| Timer Output| 100%| Fixed output|
| Timer Wind| 100%| Fixed wind|
| Timer Int| 0s – 2500s| Timer interval|
| Timer Dur| 0s – 250s| Timer duration|
| CONTINUED ON NEXT PAGE|
INFORMATION
(continued)| No Fluid| Normal / Empty| Fluid level status|
LCD Ver| Vx.x| LCD version num- ber|
Sftwr Ver| Vx.x| Software version number|
- NOTE: When the relevant module for a selected mode is not installed, selecting the mode will prompt a message that reads “Optional Module Not Installed”.
MESSAGE SMALL ICONS
| Icons displayed
after inserting MagFly module| Left to right: weakest to strongest signal
| Icons displayed
after inserting Wifi module| Left to right: weakest to strongest signal
| Icon displayed after inserting MagRF module| Icon appears if RF signal is
present
| Icon displayed after connecting wired remote| Icon appears if remote wire is
connected
PRESET MODE
Preset Mode| Duration| Interval| Fog Output|
Wind Intensity
---|---|---|---|---
1| 40 min| 20 min| 100%| 100%
2| 30 min| 15 min| 100%| 100%
3| 20 min| 10 min| 100%| 100%
4| 10 min| 5 min| 100%| 100%
5| 5 min| 5 min| 100%| 100%
PRESET SCREEN
DMX CHANNEL FUNCTIONS & VALUES
CHANNEL | VALUES | FUNCTION |
---|---|---|
1- CH | 3-CH |
1
| ****
1
| | Fog
000 – 005| Off
006 – 255| On
| ****
2
| | Duration
000 – 005| Off (0s)
006 – 255| On, 1s – 250s (steps of 1s)
| ****
3
| | Interval
000 – 005| Off (0s)
006 – 255| On, 10s – 2500s (steps of 10s)
DIMENSIONAL DRAWINGS
Dimensions may not be drawn to scale.
TROUBLE SHOOTING
If you experience low output, pump noise, or no output at all, disconnect the device and discontinue use immediately. Do not attempt to continue operation as this may damage the machine. Check the fluid level, the breaker, and the wall outlet to make sure that it is sending power. If all the above factors do not appear to be causing the issue, and the unit still fails to operate correctly, the unit will require service. Please contact Magmatic Effects for assistance.
CLEANING & MAINTENANCE
When storing your device, be sure to store in a cool area. Cover the device to that dust does not build up on the device. When storing for long periods of time it is highly advisable to run the device at least once every 3-4 months. Long periods of inactivity can severely shorten the life of your device. Only run Magmatic’s Atmosity fluid (SKU# ARH and AAH) through your machine. Never run plain water, vinegar, or any other liquid solution through your device, as doing so will severely damage your device.
SPECIFICATIONS
PERFORMANCE
- Rated Power: 350W
- Max Output: 3,800 CFM* (cu ft/min.) ()
- Ready Time: Instant
- Fluid Capacity: 0.66043 Gallons (2.5 liters)
- Fluid Consumption: 0.033814 oz/min (1.0 ml/min)
COMPATIBLE FLUID
- Atmosity ARH (Oil Based Fluid)
CONSTRUCTION
- Advanced HPA (high pressure air) Pump Technology Energy Saving Mode with Auto-Clean Process
- Sealed Fluid Reservoir
- External Visual Fluid Level Detection
- Compact Light Weight Mobile Design
CONTROL
- 2 DMX Channel Modes (1 / 3)
- Onboard LCD Touch Control Panel
- DMX-512 and RDM Protocol Support
- Optional MAGFLY Wireless DMX Transceiver
- Optional MAGRF Wireless and Wired Remotes
CONNECTIONS
- Locking 5pin XLR Connector In/Out
- IP65 Locking Power Connector In
- With Wired Digital Communication Network
SIZE / WEIGHT
- Length: 20.2 in. (514.1mm)
- Width: 14.7 in. (374.1mm)
- Height: 14.1 in. (365.1mm)
- Weight: 66 lbs. (30kg)
ELECTRICAL
- AC120V 60Hz (US Version)
- AC230V 50Hz (EU Version)
- 10A Breaker (US Version)
- 5A Breaker (US Version)
- Max Power Consumption: 370W
THERMAL
- Maximum Ambient Temperature (Ta max) 104°F (40°C) Exterior Surface Temperature, Steady State: 122°F (50°C)
- APPROVALS / RATINGS
- CE | cETLus (pending)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>