PSD108 Prisma Driver 8 48VDC Driver for Prisma Lights
User Manual
©2022 MAGMATIC EFFECTS all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without
notice. MAGMATIC EFFECTS logo and identifying product names and numbers
herein are trademarks of MAGMATIC EFFECTS. Copyright protection claimed
includes all forms and matters of copyrightable materials and information now
allowed by statutory or judicial law or hereinafter granted. Product names
used in this document may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged. All nonmagnetic brands and
product names are trademarks or registered trademarks of their respective
companies.
MAGMATIC EFFECTS and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
MAGMATIC EFFECTS
6122 S. Eastern Ave.
Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax
www.elationlighting.com |
sales@magmaticeffects.com
Elation Professional B.V.
Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax
www.elationlighting.eu |
info@elationlighting.eu
Elation Professional Mexico
AC Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 728-282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version
of this document may be available online. Please scan the QR Code with your
mobile device or
visitwww.elationlighting.com for the latest
revision/update of this manual, before installation and/or programming.
Date| Document
Version| Software Version ≥| DMX Channel Modes| Notes
---|---|---|---|---
6/17/2020| 1.0| 1.| 8 / 9 /12 Channels| Initial release.
9/15/2020| 1.| 1.| No Change| Updated primary/secondary
5/18/2022| 1.| N/C| No Change| Added RDM, and updated General Information.
GENERAL INFORMATION
INTRODUCTION
This device can be used to control the following Magmatic units:
- Prisma Mini Bar 20
- Prisma Mini Par 20
- Prisma Mini Par 45
Please read and understand the instructions in this manual carefully and
thoroughly before attempting to operate this device. These instructions
contain important safety and use information. This product is intended to be
used by professionally trained personnel only and is not suitable for private
use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton is damaged, carefully inspect the
device for damage, and be sure all accessories necessary to install and
operate the device have arrived intact. In the event, that damage has been
found or parts are missing, please contact our customer support team for
further instructions. Please do not return this device to your dealer without
first contacting customer support. Please do not discard the shipping carton
in the trash. Please recycle whenever possible.
BOX CONTENTS
Driver Unit (x1)
Twist Locking Power Cable (x1)
CUSTOMER SUPPORT
Contact MAGMATIC Service for any product-related service and support needs.
Also visit forums.elationlighting.com
with questions, comments, or suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm
PST323-582-3322 | Fax
323-832-9142 |
support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET +31 45 546 85
63 | Fax +31 45 546 85 96
|support@elationlighting.eu
REPLACEMENT PARTS please
visitparts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
LIMITED WARRANTY (USA ONLY)
A. Magmatic Effects hereby warrants, to the original purchaser, Magmatic
products to be free of manufacturing defects in material and workmanship for a
period of two years (730 days) from the original date of purchase. This
warranty excludes discharge lamps and all product accessories. This warranty
shall be valid only if the product is purchased within the United States of
America, including possessions and territories. It is the owner’s
responsibility to establish the date and place of purchase by acceptable
evidence, at the time service is sought.
B. For warranty service, send the product only to the Magmatic Effects
factory. All shipping charges must be pre-paid. If the requested repairs or
services (including parts replacement) are within the terms of this warranty,
Magmatic Effects will pay return shipping charges only to a designated point
within the United States. If any product is sent, it must be shipped in its
original package and packaging material. No accessories should be shipped with
the product. If any accessories are shipped with the product, Magmatic Effects
shall have no liability whatsoever for loss and/or damage to any such
accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are
altered or removed; if the product is modified in any manner that Magmatic
Effects concludes, after inspection, affects the reliability of the product;
if the product has been repaired or serviced by anyone other than the Magmatic
Effects factory unless prior written authorization was issued to purchaser by
Magmatic Effects; if the product is damaged because not properly maintained as
set forth in the product instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any
maintenance, cleaning, or periodic check-up. During the periods specified
above, Magmatic Effects will replace defective parts at its expense and will
absorb all expenses for warranty service and repair labor by reason of defects
in material or workmanship. The sole responsibility of Magmatic Effects under
this warranty shall be limited to the repair of the product, or replacement
thereof, including parts, at the sole discretion of Magmatic Effects. All
products covered by this warranty were manufactured after January 1, 1990, and
bear identifying marks to that effect.
E. Magmatic Effects reserves the right to make changes in design and/or
performance improvements upon its products without any obligation to include
these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with
respect to any accessory supplied with the products described above. Except to
the extent prohibited by applicable law, all implied warranties made by
Magmatic Effects in connection with this product, including warranties of
merchantability or fitness, are limited in duration to the warranty periods
set forth above. And no warranties, whether expressed or implied, including
warranties of merchantability or fitness, shall apply to this product after
said periods have expired. The consumer’s and/or dealer’s sole remedy shall be
such repair or replacement as is expressly provided above; and under no
circumstances shall Magmatic Effects be liable for any loss and/or damage,
direct and/or consequential, arising out of the use of, and/or the inability
to use, this product.
G. This warranty is the only written warranty applicable to Magmatic
Effects products and supersedes all prior warranties and written descriptions
of warranty terms and conditions heretofore published.
WARRANTY RETURNS (USA ONLY)
To obtain warranty service, a Return Material Authorization (RMA) number must
first be obtained from MAGMATIC. It is the Customer’s responsibility to
provide product proof of purchase and serial number by acceptable evidence
such as an invoice copy or an approved MAGMATIC Extended Warranty Certificate
(“EWC”) and any relevant maintenance records at the time warranty service is
sought. Failure to provide acceptable evidence of product proof of purchase or
EWC and any relevant maintenance records may be cause for denial of warranty
service.
Products returned for warranty service must be sent without any accessories
(i.e., power, data, and safety cables, brackets, clamps, rigging hardware,
frost filters, gel frames, barn doors, lenses, hoses, nozzles, rack mounting
hardware, etc.), must be boxed using the original and/or suitable packaging
materials (double-box and foam) that provides ample product protection for
ground and/or air freight transit, and must be shipped freight pre-paid and
insured to MAGMATIC in Los Angeles, CA or a MAGMATIC Authorized Service
Center. The RMA number must be clearly written on the outside of the return
box, and a brief description of the problem and the RMA number must be
documented and included in the box.
Products returned for warranty service without an RMA number clearly marked on
the outside of the package will be refused and returned to the shipper at the
Customer’s expense. Products returned for warranty service, which is received
damaged due to inadequate and/or improper packaging and/or due to damage
caused by the shipping carrier, may incur additional repair charges before
warranty service begins and/or may void this warranty. If any product
accessories (included and/or optional) are shipped with the product, MAGMATIC
and/or the MAGMATIC Authorized Service Center shall have no liability
whatsoever for the loss and/or damage to any such accessories, nor the safe
return thereof. If the requested warranty repairs or service (including parts
replacement) are within the terms of this warranty, MAGMATIC will pay return
ground transportation shipping charges to a single designated point within the
United States.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee
smooth operation, it is important to follow all instructions and guidelines in
this manual. Magmatic Effects is not responsible for injury and/or damages
resulting from the misuse of this fixture due to the disregard of the
information printed in this manual. Only qualified and/or certified personnel
should perform the installation of this fixture and only the original rigging
parts included with this fixture should be used for installation. Any
modifications to the fixture and/or the included mounting hardware will void
the original manufacturer’s warranty and increase the risk of damage and/or
personal injury.
PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED
THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG THE DRIVER INTO A DIMMER PACK!
NEVER OPEN THIS DRIVER WHILE IN USE!
UNPLUG POWER BEFORE SERVICING THE DRIVER!
NEVER TOUCH FIXTURES DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURES!
IP20: FIXTURE IS PROTECTED AGAINST SOLIDS APPROXIMATELY THE SIZE OF AN ADULT
FINGER, OR LARGER. FIXTURE IS NOT PROTECTED AGAINST LIQUID INSTRUCTION OF ANY
KIND.
– DO NOT TOUCH the driver housing during operation. Turn OFF the power
and allow approximately 15 minutes for the driver to cool down before
servicing.
– DO NOT shake the driver and avoid brute force when installing and/or
operating.
– DO NOT operate the driver if the power cord is frayed, crimped,
damaged, and/or if any of the power cord connectors are damaged and do not
insert into their sockets securely and with ease. NEVER force a power cord
connector into a socket. If the power cord or any of its connectors is
damaged, replace it immediately with a new one of a similar power rating.
– DO NOT block any air ventilation slots.
– All fan and air inlets must remain clean and free of dust and debris.
– Allow approx. 6″ (15cm) between the fixture and other devices or a wall for
proper cooling.
– Always disconnect the driver from the main power source before performing
any type of service and/or cleaning procedure. Only handle the power cord by
the plug end, and NEVER pull out the plug by tugging the wire portion of
the cord.
– Consistent operational breaks will ensure the driver will function properly
for many years.
– ONLY use the original packaging and materials to transport the driver
for service.
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to ensure proper function and extended life.
The frequency of cleaning depends on the environment in which the driver
operates: damp, smoky, or particularly dirty environments can cause a greater
accumulation of dirt on the driver. Clean the external surface periodically
with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended
life. There are no user-serviceable parts inside this driver, please refer all
other service issues to an authorized MAGMATIC service technician. Should you
need any spare parts, please order genuine parts from your local MAGMATIC
dealer.
Please refer to the following points during routine inspections:
– A detailed electrical check by an approved electrical engineer every three
months, to make sure the circuit contacts are in good condition in order to
prevent overheating.
– Be sure all screws and fasteners are securely tightened at all times. Loose
screws may fall out during normal operation, resulting in damage or injury as
larger parts could fall.
– Check for any deformations on the housing, rigging hardware, and rigging
points (ceiling, suspension, trussing). Deformations in the housing could
allow for dust or liquids to enter the driver. Damaged rigging points or
unsecured rigging could cause the driver to fall and seriously injure a
person(s).
– Electric power supply cables must not show any damage, material fatigue, or
sediments.
NEVER remove the ground prong from the power cable.
DRIVER OVERVIEW
1. Mounting Points
2. Display Screen
3. Mode Button
4. Down Button
5. Up Button
6. Enter Button| 7. 5-pin DMX In
8. 5-pin DMX Out
9. Fuse T3A/250V
10. Power In
11. Power Out
12. Signal Out Ports
---|---
INSTALLATION INSTRUCTIONS
FLAMMABLE MATERIAL WARNING
Keep the driver a minimum of 5.0 feet (1.5m) away from flammable materials
and/or pyrotechnics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or
installations.
DO NOT INSTALL THE DRIVER IF YOU ARE NOT QUALIFIED TO DO SO!
Driver MUST be installed following all local, national, and country
commercial electrical and construction codes and regulations.
Before rigging/mounting a single device or multiple interconnected devices for
custom matrix designs to any metal truss/structure or placing the device(s) on
any surface, a professional equipment installer MUST be consulted to
determine if the metal truss/structure or surface is properly certified to
safely hold the combined weight of the device(s), clamps, cables, and
accessories.
The ambient operating temperature range is from -4°F (-20°C) to 122°F
(50°C). Do not operate this device when the ambient temperature falls
outside this range.
Device(s) should be installed in areas outside walking paths, seating areas,
or away from areas where unauthorized personnel might reach the device(s) by
hand.
PHOENIX CONNECTORS
This driver is compatible for use with the following Magmatic lighting
fixtures: Prisma Mini BAR 20, Prisma Mini PAR 45 , and Prisma Mini PAR
20. A set of Phoenix connectors is included with this driver and may be used
to connect these fixtures to the driver.
Begin by inserting the male end of the Phoenix connector into the desired signal output port on the driver, making sure that the latch on the Phoenix connector engages with the signal output port. Tighten the two screws located on each side of the wire terminals, as highlighted in the image to the above right.
Now insert the wire leads from the fixture into the wire terminals of the
Phoenix connector, making sure that the bare wire lead ends have been fitted
with wire end sheaths. Tighten the two screws above the wire terminals, as
shown in the image above right, to secure the wire leads in the Phoenix
connector.
MOUNTING
The driver may be secured to a surface or mounting rail by using the four (4)
mounting points located on the mounting brackets on either side of the driver.
REMOTE DEVICE MANAGEMENT (RDM)
NOTE: In order for RDM to work properly, RDM-enabled equipment must be used
throughout the entire system, including DMX data splitters and wireless
systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512
data standard for lighting, allowing the DMX systems of the fixtures to be
modified and monitored remotely. This protocol is ideal for instances in which
a unit is installed in a location that is not easily accessible.
With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM-
enabled controller to send out a signal to devices on the wire, as well as
allowing the fixture to respond (known as a GET command). The controller can
then use its SET command to modify settings that would typically have to be
changed or viewed directly via the unit’s display screen, including the DMX
Address, DMX Channel Mode, and Temperature Sensors. Please be aware that not
all RDM devices support all RDM features, and therefore it is important to
check beforehand to ensure that the equipment that you are considering
includes all of the features that you require.
The following parameters are accessible in RDM on this device:
Sensor Definition
Sensor Value
Device Model Description
Manufacturer Label
Device Label
DMX Personality
DMX Personality Description
Device Hours
Display Invert
SYSTEM MENU
The fixture includes an easy-to-navigate system menu. The control panel (see
image below) located on the fixture provides access to the main system menu,
where all necessary system adjustments can be made. During normal operation,
pressing the MODE button once will access the fixture’s main menu. Once in
the main menu, you can navigate through the different functions and access the
sub-menus with the UP and DOWN buttons. Once you reach a field that
requires adjusting, press the ENTER button to activate that field and use
the UP and DOWN buttons to adjust the field. Pressing the ENTER
button once more will confirm your setting. You may exit the main menu at any
time without making any adjustments by pressing the MODE button.
The display screen will automatically time out after an extended period of
inactivity. To unlock the display screen, simply press and hold the MODE
until the display screen unlocks.
Magmatic Prisma Driver 8 System Menu
The default setting is shown in bold
Supports Software Versions: 1.01
ADDRESS| Address XXX| 001 – 504| |
USER MODE| Basic (8CH)| | |
Standard (9CH)| | |
Extended (12 CH)| | |
FUNCTION| Status| Lost DMX| Black / Hold|
LCD Set| Display| On / Off| 30-second screen time- out
Key Lock| On / Off| Lock screen keys
Flash| On / Off| The display screen will flash when the DMX connection is
absent
Invert| Off / On| Flip screen display
Dim Mode| Standard| |
Stage| |
TV| |
Archives| |
Theatre| |
Stage2| |
0.0 s| |
0.1 s| |
0.2 s| |
0.3 s| |
0.4 s| |
0.5 s| |
0.6 s| |
0.7 s| |
0.8 s| |
0.9 s| |
1.0 s| |
1.5 s| |
2.0 s| |
3.0 s| |
4.0 s| |
5.0 s| |
6.0 s| |
7.0 s| |
8.0 s| |
9.0 s| |
10.0 s| |
Disp Set| ADDR| |
Disp CH| |
Secondary| | Secondary mode
Dim Curve| Linear| |
Square| |
Inv. Squad| |
S Curve| |
Magmatic Prisma Driver 8 System Menu
The default setting is shown in bold
Supports Software Versions: 1.01
FUNCTION
(continued from the last page)| Frequent| 900 Hz| |
1000 Hz| |
1100 Hz| |
1200 Hz| |
1300 Hz| |
1400 Hz| |
1500 Hz| |
2500 Hz| |
4000 Hz| |
5000 Hz| |
10000 Hz| |
15000 Hz| |
20000 Hz| |
25000 Hz| |
primary SW| On / Off| | Set device as PRIMARY
DFSE| On / Off| | Restore factory default settings
INFO| TimeInfo| Current| | Current fixture run time (hours)
Total| | Total fixture run time (hours)
Last| | Clear current fixture run time
Password| | “050” or “060”
Clear| On / Off|
Model Inf| DRIVER 8| |
Software| V1.01| |
TEST| ManCtrl| Led1| 000 – 255|
Led2| 000 – 255|
Led3| 000 – 255|
Led4| 000 – 255|
Led5| 000 – 255|
Led6| 000 – 255|
Led7| 000 – 255|
Led8| 000 – 255|
Dimmer| 000 – 255|
Strobe| 000 – 255|
Calibrate| Password| 000 – 255|
Led1| 050 – 255|
Led2| 050 – 255|
Led3| 050 – 255|
Led4| 050 – 255|
Led5| 050 – 255|
Led6| 050 – 255|
Led7| 050 – 255|
Led8| 050 – 255|
D MX CHANNEL FUNCTIONS AND VALUES
8-CH BASIC MODE
Magmatic Prisma Driver 8: DMX Channels / Functions
Supports Software Versions: 1.01
CHANNEL
| VALUE|
FUNCTION
1| 000 – 255| LED Signal Output 1
2| 000 – 255| LED Signal Output 2
3| 000 – 255| LED Signal Output 3
4| 000 – 255| LED Signal Output 4
5| 000 – 255| LED Signal Output 5
6| 000 – 255| LED Signal Output 6
7| 000 – 255| LED Signal Output 7
8| 000 – 255| LED Signal Output 8
9-CH STANDARD MODE
Magmatic Prisma Driver 8: DMX Channels / Functions
Supports Software Versions: 1.01
CHANNEL
| VALUE|
FUNCTION
1| 000 – 255| LED Signal Output 1
2| 000 – 255| LED Signal Output 2
3| 000 – 255| LED Signal Output 3
4| 000 – 255| LED Signal Output 4
5| 000 – 255| LED Signal Output 5
6| 000 – 255| LED Signal Output 6
7| 000 – 255| LED Signal Output 7
8| 000 – 255| LED Signal Output 8
9|
Dim Mode
000 – 020| Standard
021 – 040| Stage
041 – 060| TV
061 – 080| Architectural
081 – 100| Theatre
101 – 120| Stage2
Dimmer Delay Time
121| 0.0 s
122| 0.1 s
123| 0.2 s
124| 0.3 s
125| 0.4 s
126| 0.5 s
127| 0.6 s
128| 0.7 s
129| 0.8 s
130| 0.9 s
131| 1.0 s
CHANNEL
| VALUE|
FUNCTION
---|---|---
9
(continued from prev page)|
Dimmer Delay Time (continued from prev page)
132| 1.5 s
133| 2.0 s
134| 3.0 s
135| 4.0 s
136| 5.0 s
137| 6.0 s
138| 7.0 s
139| 8.0 s
140| 9.0 s
141| 10.0 s
142 – 255| Default (0.1 s)
12-CH EXTENDED MODE
Magmatic Prisma Driver 8: DMX Channels / Functions
Supports Software Versions: 1.01
CHANNEL
| VALUE|
FUNCTION
1| 000 – 255| LED Signal Output 1
2| 000 – 255| LED Signal Output 2
3| 000 – 255| LED Signal Output 3
4| 000 – 255| LED Signal Output 4
5| 000 – 255| LED Signal Output 5
6| 000 – 255| LED Signal Output 6
7| 000 – 255| LED Signal Output 7
8| 000 – 255| LED Signal Output 8
9| 000 – 255| Master Dimmer
10| 000 – 255| Dimmer Fine
11|
Strobe
000 – 031| Closed
032 – 063| Open
064 – 095| Strobe, Slow to Fast
096 – 127| Open
128 – 159| Pulse, Slow to Fast
160 – 191| Open
192 – 223| Random Strobe, Slow to Fast
224 – 255| Open
12|
Dim Mode
000 – 020| Standard
021 – 040| Stage
041 – 060| TV
061 – 080| Architectural
081 – 100| Theatre
101 – 120| Stage2
Dimmer Delay Time
121| 0.0 s
122| 0.1 s
123|
CHANNEL
| VALUE|
FUNCTION
---|---|---
12
(continued from prev page)|
Dimmer Delay Time (continued from prev page)
124| 0.3 s
125| 0.4 s
126| 0.5 s
127| 0.6 s
128| 0.7 s
129| 0.8 s
130| 0.9 s
131| 1.0 s
132| 1.5 s
133| 2.0 s
134| 3.0 s
135| 4.0 s
136| 5.0 s
137| 6.0 s
138| 7.0 s
139| 8.0 s
140| 9.0 s
141| 10.0 s
142 – 255| Default (0.1 s)
DIMMER MODES
Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre, Stage2).
Dimming Curve
Ramp Effect| 0 sec Fade Time| 1 sec Fade Time
---|---|---
|
| Rise Time (ms)| Down Time (ms)| Rise Time (ms)| Down Time
(ms)
Standard (default)| 0| 0| 0| 0
Stage| 780| 1100| 1540| 1660
TV| 1180| 1520| 1860| 1940
Architectural| 1380| 1730| 2040| 2120
Theatre| 1580| 1940| 2230| 2280
Stage 2| 0| 1100| 0| 1660
SPECIFICATIONS
CONSTRUCTION
Rugged Aluminum Housing
Easy Keyhole Slots for Wall/Surface Mounting
CONTROL
Multiple DMX Channel Modes
Onboard 4 Button Touch Control Panel
DMX-512 and RDM Protocol Support
CONNECTIONS
8x 2pin Bare Wire Block Terminals (8 PRISMA MINI fixtures max)
Locking 5pin XLR Connector In/Out
IP65 Locking Power Connector In/Out
With Wired Digital Communication Network
SIZE/WEIGHT
Length: 8.9 in. (225mm)
Width: 8.4 in. (212mm)
Vertical Height: 3.5 in. (88mm)
Weight: 5.7 lbs. (2.6 kg)
ELECTRICAL
AC100-240V 50-60Hz
48VDC 8.3A
167W Max Power Consumption
THERMAL
Maximum Temperature (Ambient): 113° F (45° C)
Minimum Temperature (Ambient): 14° F (-10°)
APPROVALS/RATINGS
CE | cETLus | IP20
Specifications and improvements in the design of this unit and this manual
are subject to change without any prior written notice.
DIMENSIONAL DRAWINGS
Drawings not to scale.
SKU#: PSD108
EU#: 1237000230
UPC#: 810008261194
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>