Anolis DIVINE 60 UV 180W Full LED Luminaire Instruction Manual

June 12, 2024
ANOLiS

Anolis-logo

Anolis DIVINE 60 UV 180W Full LED Luminaire

Anolis-DIVINE-60-UV-180W-Full-LED-Luminaire-product

Product Information

Product Name: Divine 60 UV
Manufacturer: ROBE lighting s. r. o.
Address: Palackeho 416, 757 01 Valasske Mezirici, Czech Republic
Contact: Tel.: +420 571 751 500,
E-mail: info@anolis.eu
Website: www.anolislighting.com
Version: 2.0 / 2_2023 Product Usage

Instructions:

Step 1: Cable Gland
1A. For bottom connection, use the cable gland.
1B. For side connection, use the cable gland.
Step 2: Uncover Junction Box
Uncover the junction box located on the bottom side of theluminaire to access the power and data inlets.
Step 3: Connection
Strip the cable to appropriate lengths for power and data connections. For power connection, use a 5-cored cable Flamar Li9YC11Y with  brown, blue, and yellow/green wires. For data connection, use shielded cores with white, red, and shielding wires.
Step 4: Control Menu
Set the control menu inside or outside the junction box as required.
Step 5: Close Junction Box
Close the junction box securely after making the necessary connections.
Step 6: Cable Gland Installation
Use the appropriate wrench size (24 for M20x1.5 or 16 for M12x1.5) to install the cable gland.
Step 7: Installation
7.A. Installation with Surface Mount Adaptor 1: Apply LOCTITE 5331 paste on the plastic holder of the cable gland before inserting it into the body of the gland. Apply LOCTITE 577 paste on the thread of the gland body. Mount the adaptor using 6 mounting screws. 7.B. Installation with Set of Rubber Feet: Drill holes on the surface according to hole spacing. Mount Divine using the mounting holes and rubber feet.
7.C. Installation with C-Clamp Adaptor: Mount a pair of rubber feet using 4 screws. Mount the adaptor using 5 screws.
Step 8: Installation of Accessories
Install the desired accessories such as Adaptor Black Glass, Half Top Hat, Top Hat, or Wire Guard/Anti-Glare.

INSTALLATION INSTRUCTIONS

1B For side connection

Inlets for power and data from side of the luminaire.

STEP 1
CABLE GLAND

Inlets for power and data from bottom side of the luminaire.

STEP 2
UNCOVER JUNCTION BOX

Uncover junction box located on the bottom side of luminaire.

STEP 3
CONNECTION

Strip these lenghts for cable connections

Connection – colour coding

To connect the Divine 60 UV to mains and a DMX controller, use a 5-cored cable Flamar Li9YC11Y. The 3 colors serve for the power supply and 2 shielded cores are intended for DMX connection.

Power and D ata Connection

Wiring connection (control menu inside)

Wiring connection (control menu outside)

STEP 4
CONTROL MENU

Control menu inside

Set control menu inside junction box.

Control menu outside

Set control menu.

STEP 5
CLOSE JUNCTION BOX

Before applying the torque, make sure the thread is clean and functional.

STEP 6
CABLE GLAND INSTALLATION

Use wrench size 24 for cable gland M20x1.5
Use wrench size 16 for cable gland M12x1.5
Install Cable glands individually!

We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting in into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread ofthe gland body.

Failure to properly install cable glands will result in failure of the water tight seal!

STEP 7.A
INSTALLATION WITH SURFACE MOUNT ADAPTOR

Mount the adaptor using 6 mounting screws.

STEP 7.B
INSTALLATION WITH SET OF RUBBER FEET

Mount pair of rubber feet using 4 screws.

Drill holes to the surface according to holes spacing. Mount Divine via mounting holes on the surface.

STEP 7.C
INSTALLATION WITH C-CLAMP ADAPTOR

Mount the adaptor using 5 screws.

TYPE OF ACCESSORIES

Adaptor Black Glass

Half Top Hat

Top Hat

Wire Guard/Anti-Glare

STEP 8
INSTALLATION OF ACCESSORIES

Unscrew two screws and split accessory to two parts. Place each part onto the luminaire´s head and screw them together.

Secure accessory by 4 screws with spring washer at the back side of the luminaire´s head.

STEP 9
HEAD POSITION ADJUSTMENT

Release locking screw on each sides. Angle fixture to desired position and tighten locking screw on each sides..