QTM-eLED+0-10V-AWN LED Power Supply
Installation Guide INSTALLATION LED
POWER SUPPLY – QTM-eLED+0-10V-AWN
QTM-eLED+0-10V-AWN LED Power Supply
Must be installed by licensed electrician.
WARNING
Risk of Fire / Electric Shock
Transformer should be installed by a Licensed electrician in accordance with
the N.E.C. and all local codes in force.
LOW VOLTAGE LIGHTING SYSTEM CLASS: 3425-15 3425-95
- Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
- This power supply must be installed according to the National Electric
- Code and local codes and ordinances.
- This power supply is to be installed and serviced only by an licensed electricians.
- This power supply is to be installed so that it is not likely to be contacted by people.
- To avoid a hazard to children, account for all parts and destroy all packaging materials.
- Do not install in wet locations.
Node And Conduit Entry Locations
RECESSED MOUNT
SURFACE MOUNT
NOTE: AWN-3 is available for QTM-eLED+WD and QTM-eLED+0-10V only.
Conduit Entry Locations
Athena nodes must be installed on the secondary side of power supply center
and require 1.0″ of clearance in order to optimally function. Metal conduit
must be 1.0″ away from any node. Refer to the diagram above for
recommendations for conduit entry into secondary compartment.
Lutron Athena Node
Mounted in the secondary wiring compartment only
Mounting Options
Driver with Lutron Athena Node
QTM-eLED-300W+0-10V-AWN-3 : for interior
CSA Requirements
- Suitable for Indoor use
- This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation code by a person familiar with the construction and operation of the produc the hazards involved.
- Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
- This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
- To avoid a hazard to children, account for all parts and destroy all packaging materials.
- Type Ic Recessed, Inherently Protected
- For Supply Connections Use Wire Rated For At Least 60 C.
- Not for use with dimmers
- Suitable For Damp Locations
- 50/60 Cycle
- Class 1 or Class 2
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
LOW VOLTAGE
LIGHTING SYSTEM
Q-Tran, Inc.
CLASS: 3425 – 15
3425 – 95
Q-TRAN, INC.
MILFORD, CT U.S.A.
{203) 367-8777
WWW.Q-TRAN.COM
© 2023 Q-Tran Inc. All rights reserved
155 Hill St. Milford, CT 06460
203-367-8777
sales@q-tran.com
www.q-tran.com
Specification subject to change. Rev-08-03-23