BEA BR3-X Programmable 3 Relay Logic Module User Guide
- June 13, 2024
- BEA
Table of Contents
BEA BR3-X Programmable 3 Relay Logic Module
BEFORE BEGINNING INSTALLATION
READ BEFORE BEGINNING INSTALLATION & SET-UP
- Shut off all power going to header before attempting any wiring procedures.
- Maintain a clean and safe environment when working in public areas.
- Constantly be aware of pedestrian traffic around the door area.
- Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
- ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board ensure you dissipate your body’s ESD charge.
- Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
- Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
- DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair:
- May jeopardize personal safety and may expose one to the risk of electrical shock.
- May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
SET-UP / WIRING
Set jumpers
RELAY 1 OUTPUT| DRY/WET JUMPER 2| AC OUTPUT VOLTAGE 1|
DC OUTPUT VOLTAGE 2
---|---|---|---
DRY| both jumpers set to DRY| N/A| N/A
WET1| both jumpers set to WET| both jumpers set to AC| both jumpers set to DC
Wiring according to desired function (reference full User’s Guide for complete set of wiring diagrams).
NOTES
- If voltage Input at the Br3-X is AC, then output selection can be AC or DC.
- When DC ‘WET’ output is selected, COM terminal is positive (+) and the ground (-) is switched between NO and NC.
PROGRAMMING
- Press and hold INCR + FUNC for 3 seconds.
- Display will toggle between FF / 00 for 5 seconds.1,2
- While FF / 00 is displayed, press INCR to cycle through functions.
- Once desired function is selected, press FUNC to cycle through parameters.
- Display will toggle between parameter and its current value for 5 seconds.
- Press 3 INCR to cycle through parameter’s values.
- Repeat steps 4-7 until all function parameters are set.
- Wait 5 seconds for Br3-X to save and display function.
- Test the device to ensure that all function parameters are working correctly and as intended for the specific application.
NOTES
- Function 00 disables the BR3-X.
- “nP” = no parameters are applicable for the selected function.
- Relay hold time(s) and delay time(s) MUST be set for any relay that is to be utilized. Ex: For function 36, if using only relay 1, h1 must be set… if using relay 1 and relay 2, h1, h2, and d1 must be set.
- Pressing and holding INCR will rapid cycle.
FUNCTIONS REFERENCE
FUNCTION | DESCRIPTION | LOGIC |
---|
10
| ****
timer
| • activation of relay 1 via trigger of input 1
• reverse logic available
11| ratchet / latching| • ratchet/latching of relay 1 via trigger of input 1
22
| ****
2-relay sequencer
+ inhibitor
| • sequence of relay 1 and relay 2 with inhibiting of input 1 until input 2, input 3, or WET input is triggered
• activation of input 4 reinhibits input 1
28
| 2-relay sequencer
+ door position
| • sequence of relay 1 and relay 2 via trigger of input 1 or WET input
• input 2 allows delay to run when open but not when closed
29
| ****
deactivation timer
| • sequence of relay 1 and relay 2 via trigger of input 1 or WET input
• input 2, once opened after sequence, allows relay 1 to deactivate
• input 2 allows delay to run when open but not when closed
• input 3 disables sequence, reverse logic available
36
| 3-relay sequencer
+ ‘1-shot’
| • sequence of relay 1 and relay 2 and relay 3 via trigger of input 1 or WET input
• relay 1, relay 2, and relay 3 can be maintained or ‘1-shot’
37
| 3-relay sequence with
‘independent relay’
| • sequence of relay 1 and relay 2 and relay 3 via trigger of input 1 or WET input
• relay 1, relay 2, and relay 3 can be ‘independent’ or sequenced
50| interlock timer| • interlock of relay 1 and relay 2 via trigger of input 1 and input 2, respectively
55
| interlock ratchet / latching| • interlock ratchet of relay 1 and relay 2 via trigger of input 1 and input 2, respec- tively
65
| ****
2-way 2-relay sequence
| • sequence of relay 1 and relay 2 via trigger of input 1
• sequence of relay 2 and relay 1 via trigger of input 2
• input 3 triggers relay 1 individually, input 4 triggers relay 2 individually
NL
| normally locked restroom| • sequence of relay 1 (lock), relay 2 (door), and relay 3 (occupied indicators) for normally locked, single occupancy restrooms
NU
| normally unlocked restroom| • sequence of relay 1 (lock), relay 2 (door), and relay 3 (occupied indicators) for normally unlocked, single occupancy restrooms
DN
| 3-relay sequencer + ‘day / night mode’| • sequence of relay 1 and relay 2 and relay 3 via trigger of input 1 or WET input
• input 2 operation dependent upon input 4 (‘day / night mode’)
00
| ****
disable
| • Br3-X disabled
• 00 is the default setting and has no assigned function
PARAMETERS REFERENCE
PARAMETER | DESCRIPTION | LOGIC |
---|
h1*
| ****
relay 1 hold time
| 00 – 60 seconds
countdown begins AFTER release of input 1 or WET input
h2*
| ****
relay 2 hold time
| 00 – 60 seconds
countdown begins AFTER d1 (delay between relay 1 & relay 2) expires
h3*
| ****
relay 3 hold time
| 00 – 60 seconds
countdown begins AFTER d2 (delay between relay 1 & relay 3) expires
d1
| delay between relay 1 & relay 2| 00 – 60, _1 (1/4), _2 (1/2), _3 (3/4) seconds delay begins AT activation of input 1 or WET input
d2
| delay between relay 1 & relay 3| 00 – 60, _1 (1/4), _2 (1/2), _3 (3/4) seconds delay begins AT activation of input 1 or WET input
rL
| ****
reverse logic
| 00 = normal logic
input 1 trigger must be NO and close its contact to trigger
| 01 = reverse logic
input 1 trigger must be NC and open its contact to trigger
nP| no parameters| no parameters available for selected function
TECHNICAL SPECIFICATIONS
Supply Voltage | 12 − 24 VAC/VDC ±10% |
---|---|
Current Consumption | 30 − 130 mA (DRY output) |
Input
Input 1, 2, 3, 4 WET input
| ****
DRY contact
5-24 VAC/VDC ±10%
Contact Rating Relay 1 (DRY)
Relay 1 (WET)
Relay 2
Relay 3
| ****
3 A @ 24 VAC or 30 VDC
1 A
3 A @ 24 VAC or 30 VDC
1 A @ 24 VAC or 30 VDC
Specifications are subject to change without prior notice.
All values measured in specific conditions.
COMPLIANCE EXPECTATIONS
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/ gates, and factory-trained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards. Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices.
Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code). Verify that all appropriate industry signage, warning labels, and placards are in place.
Contact
- Tech Support & Customer Service: 1-800-523-2462
- General Tech Questions: techservices-us@BEAsensors.com
- Tech Docs: www.BEAsensors.com
Visit website for full User’s Guide and language options
Documents / Resources
| BEA
BR3-X Programmable 3 Relay Logic
Module
[pdf] User Guide
BR3-X Programmable 3 Relay Logic Module, BR3-X, Programmable 3 Relay Logic
Module, 3 Relay Logic Module, Logic Module, Module
---|---
| BEA
BR3-X Programmable 3-Relay Logic
Module
[pdf] Owner's Manual
BR3-X Programmable 3-Relay Logic Module, BR3-X, Programmable 3-Relay Logic
Module, 3-Relay Logic Module, Logic Module
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>