STABILA LD 220 Laser Distance Measurer User Manual
- June 4, 2024
- STABILA
Table of Contents
- STABILA LD 220 Laser Distance Measurer
- Product overview
- Introduction
STABILA LD 220 Laser Distance Measurer
Product overview
- On/Measure
- Area I Volume I Unit
- Clear I Off
Introduction
The person responsibility for the product must ensure that all users understand these directions and adhere to them
Battery and Instrument Set up
Battery units required
Fixation
Technical data
Accuracy with favorable conditions | + 3.0 mm I +__ 0.12 in |
---|---|
Accuracy with unfavorable conditions | + 4.0 mm I +__ 0.16 in |
Range with favorable
conditions
| 0.2-30 m I O.6-98 ft
Range with unfavorable conditions| O.2-20 m I O.6-66 ft
Smallest unit displayed| 1 mm I 0.04 in
Laser class| 2
Laser type| 635 nm, < 1 m W
0 laser point
at distances
| 6 / 18 mm
10 / 30 m
---|---
Protection class| IP54
Autom. laser switch off| after 90 s
Autom power switch off| after 180 s
Battery durability 2 x AAA| up to 5000 measurements
Dimension H x D x W| 115 x 53 x 25 mm
4.5 x 2.1 x 1 in
Weight with batteries| 95 g / 3.4 oz
Temperature range
Storage
Operation
| -25 to 70 °C
-13 to 158 °F O to 40 °C
32 to 104 °F
Favourable conditions are
White and diffuse reflecting target white painted wall, low background illumination and moderate temperatures.
Un Favourable conditions are
Targets with lower or higher reflectivity or high background illumination or temperatures at the upper or lower end of the specified temperature range. Tolerances apply from 0.2 m to 5 mwith a confidence level of 95%. With favourable conditions the tolerance may deteriorate by 0.1 mm/m for distances above 5 m. With un favourable conditions the tolerance may deteriorate by 0.15 mm/m for distances above 5 m.
Message Codes
If the message Error does not disappear after switching on the device repeatedly, contact the dealer. If the message Info appears with a number, press the Clear button and observe the following instructions
No. | Cause | Correction |
---|---|---|
204 | Calculation error | Perform measurement again. |
252 | Temperature too high | Let device cool down. |
253 | Temperature too low | Warm device up. |
254 | Battery voltage too low for measurements | Change batteries. |
255 | Received signal too |
weak, measuring time too long
| Change target surface e.g. white paper
256| Received signal too high| Change target surface e.g. white paper
257| Too much background
light
| Shadow target area.
258| Measurement outside of measuring range| Correct range.
260| Laser beam interrupted| Repeat measurement.
Laser classification
Wavelength | 635 nm |
---|---|
Maximum radiant output power used for classification | 0.95 mW |
Pulse repetition frequency | 320 MHz |
Pulse duration | >400ps |
Warranty
Stabila provides a two-year warranty for the product. Futher information
can be found on the Internet at: www.stabila.de
Areas of responsibility
Responsibilities of the manufacturer of the original equipment
STABILA Messgerate Gustav Ullrich GmbH P.O. Box 13 40 I D-76851 Annweiler Landauer Str. 45 I D-76855 Annweiler
USA/Canada
STABILA Inc. 332 Industrial Drive South Elgin, IL 60177 1.800.869.7460. The
company above is responsible for supplying the product safe condition.The
company above is not responsible for third party accessories.
Responsibilities of the person in charge of the instrument:
- To understand the safety instructions on the product and the instructions in the User
- To be familiar with local safety regulations relating to accident prevention.
- Always prevent access to the product by un authorised personnel.
STABILA Messgeriite
- Gustav Ullrich GmbH
- P.O. Box 13 40 I D-76851 Annweiler Landauer Str.45 / D-76855 Annweiler
- Tel. 00 49 (OJ 63 46 I 309 – 0
- Fax: 00 49 (OJ 63 46 I 309 – 480
- E-mail:info@stabila.de www.stabila.de
USA/Canada
STABILA Inc.332 Industrial Drive South Elgin, IL 60177 1.800.869.7460
www.stabila.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>