STABILA LD 220 Laser Distance Measurer User Manual

June 4, 2024
STABILA

STABILA LD 220 Laser Distance Measurer

Product overview

  1. On/Measure
  2. Area I Volume I Unit
  3. Clear I Off

Introduction

The person responsibility for the product must ensure that all users understand these directions and adhere to them

Battery and Instrument Set up

Battery units required
Fixation

Technical data

Accuracy with favorable conditions + 3.0 mm I +__ 0.12 in
Accuracy with unfavorable conditions + 4.0 mm I +__ 0.16 in

Range with favorable

conditions

| 0.2-30 m I O.6-98 ft
Range with unfavorable conditions| O.2-20 m I O.6-66 ft
Smallest unit displayed| 1 mm I 0.04 in
Laser class| 2
Laser type| 635 nm, < 1 m W

0 laser point

at distances

| 6 / 18 mm

10 / 30 m

---|---
Protection class| IP54
Autom. laser switch off| after 90 s
Autom power switch off| after 180 s
Battery durability 2 x AAA| up to 5000 measurements
Dimension H x D x W| 115 x 53 x 25 mm

4.5 x 2.1 x 1 in

Weight with batteries| 95 g / 3.4 oz
Temperature range

Storage

Operation

| -25 to 70 °C

-13 to 158 °F O to 40 °C

32 to 104 °F

Favourable conditions are

White and diffuse reflecting target white painted wall, low background illumination and moderate temperatures.

Un Favourable conditions are

Targets with lower or higher reflectivity or high background illumination or temperatures at the upper or lower end of the specified temperature range. Tolerances apply from 0.2 m to 5 mwith a confidence level of 95%. With favourable conditions the tolerance may deteriorate by 0.1 mm/m for distances above 5 m. With un favourable conditions the tolerance may deteriorate by 0.15 mm/m for distances above 5 m.

Message Codes

If the message Error does not disappear after switching on the device repeatedly, contact the dealer. If the message Info appears with a number, press the Clear button and observe the following instructions

No. Cause Correction
204 Calculation error Perform measurement again.
252 Temperature too high Let device cool down.
253 Temperature too low Warm device up.
254 Battery voltage too low for measurements Change batteries.
255 Received signal too

weak, measuring time too long

| Change target surface e.g. white paper
256| Received signal too high| Change target surface e.g. white paper
257| Too much background

light

| Shadow target area.
258| Measurement outside of measuring range| Correct range.
260| Laser beam interrupted| Repeat  measurement.

Laser  classification

Wavelength 635 nm
Maximum radiant output power used for classification 0.95 mW
Pulse repetition frequency 320 MHz
Pulse duration >400ps

Warranty
Stabila provides a two-year warranty for the product. Futher information can be found on the Internet at: www.stabila.de

Areas of responsibility

Responsibilities of the manufacturer of the original equipment

STABILA Messgerate Gustav Ullrich GmbH P.O. Box 13 40 I D-76851 Annweiler Landauer Str. 45 I D-76855 Annweiler

USA/Canada
STABILA Inc. 332 Industrial Drive South Elgin, IL 60177 1.800.869.7460. The company above is responsible for supplying the product safe condition.The company above is not responsible for third party accessories.

Responsibilities of the person in charge of the in­strument:

  • To understand the safety instructions on the product and the instructions in the User
  • To be familiar with local safety regulations relating to accident prevention.
  • Always prevent access to the product by un authorised personnel.

STABILA Messgeriite

  • Gustav Ullrich GmbH
  • P.O. Box 13 40 I D-76851 Annweiler Landauer Str.45 / D-76855 Annweiler
  • Tel. 00 49 (OJ 63 46 I 309 – 0
  • Fax: 00 49 (OJ 63 46 I 309 – 480
  • E-mail:info@stabila.de www.stabila.de

USA/Canada
STABILA Inc.332 Industrial Drive South Elgin, IL 60177 1.800.869.7460 www.stabila.com

STABILA LD 220 Laser Distance Measurer 2

STABILA LD 220 Laser Distance Measurer 4

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals